background image

11

Installation Instructions

CONNECTING DRYER USING 

3-WIRE CONNECTION

CONNECTING DRYER USING 

4-WIRE CONNECTION (MUST 

BE USED FOR MOBILE HOME 

INSTALLATION)

NOTE:

 Since January 1, 1996, the National Electrical 

Code requires that new constructions use a 4-wire 
connection to an electric dryer. A 4-wire cord must 
also be used where local codes do not permit grounding 
through the neutral. 3-wire connection is NOT for use 
on new construction.

1.

 Turn off the circuit breaker(s) (30 amp) or remove 

the dryer’s circuit fuse at the electrical box.

2.

 Be sure the dryer cord is unplugged from the wall 

receptacle.

3.

 Remove the power cord cover located at the lower 

back.

4.

 Remove and discard ground strap. Keep the green 

ground screw for Step 7. 

5.

 Install 3/4” UL-recognized strain relief to power cord 

entry hole. Bring power cord through strain relief. 

6.

 Connect power cord as follows:

 

A.

  Connect the 2 hot lines to the outer screws of the 

terminal block (marked L1 and L2).

 

B.

  Connect the neutral (white) line to the center of 

the terminal block (marked N).

7.

 Attach ground wire of power cord with the green 

ground screw (hole above strain relief bracket). 
Tighten all terminal block screws (3) securely.

8.

 Properly secure power cord to strain relief.

9.

 Reinstall the cover.

NEVER LEAVE THE COVER OFF OF THE 

TERMINAL BLOCK.

NEVER LEAVE THE COVER OFF OF THE 

TERMINAL BLOCK.

3-wire Connection

Not for use in Canada.
DO NOT use for Mobile Home Installations.
NOT for use on new construction.
NOT for use on recreational vehicles.
NOT for use in areas where local codes prohibit 
grounding through the neutral conduction.

1.

 Turn off the circuit breaker(s) (30 amp) or remove 

the dryer’s circuit fuse at the electrical box.

2

. Be sure the dryer cord is unplugged from the wall 

receptacle.

3.

 Remove the power cord cover located at lower back.

4.

 Install 3/4” UL-recognized strain relief to power cord 

entry hole. Bring power cord through strain relief.

5.

 Connect power cord as follows:

 

A.

  Connect the 2 hot lines to the outer screws of 

the terminal block (marked L1 and L2).

 

B.

  Connect the neutral (white) line to the center of 

the terminal block (marked N).

6

. Be sure ground strap is connected to neutral 

(center) terminal of block and to green ground 
screw on cabinet rear. Tighten all terminal block 
screws (3) securely.

7.

 Properly secure power cord to strain relief.

8.

 Reinstall the cover.

CONNECTING AN ELECTRIC DRYER (cont.)

NOTE:

 If your dryer circuit is on a circuit protected by a 

GFCI breaker, then 3-wire installation is not permitted.  
House wiring and dryer must be configured for 4-wire.

Screws 

(2)

Remove ground strap 
and discard. Keep 
green ground screw

Hot 
Wire

Relocate 

green 

ground 

screw 

here

Green 
Wire

3/4” UL  

Recognized 

Strain Relief

4 #10 AWG minimum copper conductors or 120/240V 30A power 
supply cord kit marked for use with dryers and provided with closed 
loop or spade terminals with upturned ends (not supplied).

Hot 
Wire

Neutral 

(white)

Strain 

Relief 

Bracket

Cover

Screw

Screws 

(2)

Hot 
Wire

3/4” UL  

Recognized 

Strain Relief

Hot 
Wire

Neutral 

(white)

Strain 

Relief 

Bracket

Cover

Screw

Green Ground Screw 
& Ground Strap

3 #10 AWG minimum copper conductors or 120/240V 30A power 
supply cord kit marked for use with dryers and provided with closed 
loop or spade terminals with upturned ends (not supplied).

If required, by local code, install external ground (not provided) 

to grounded metal, cold water pipe, or other established ground 

determined by a qualified electrician.

Содержание GTD72EBPNDG

Страница 1: ...ot exceed 4 feet FOR GAS DRYERS ONLY BEFORE YOU BEGIN Read these instructions completely and carefully IMPORTANT Save these instructions for local electrical inspector s use IMPORTANT Observe all gove...

Страница 2: ...Order on line at GEApplianceparts com 24 hours a day or by phone at 877 959 8688 during normal business hours STEAM WATER HOSES for steam dryer models only ACCESSORIES Order on line at GEAppliancepart...

Страница 3: ...UST be vented to the outdoors Minimum clearance between dryer cabinet and adjacent walls or other surfaces is 0 either side 1 front 1 rear 1 top For improved performance a 1 2 clearance is suggested o...

Страница 4: ...n at the same time NOTE Use new inlet hoses never use old hoses 1 Turn the cold water faucet off Remove the washer inlet hose from the washer fill valve connector cold 2 Ensure the rubber flat washer...

Страница 5: ...discard old flexible gas connector and ducting material Shut off Valve MATERIALS YOU WILL NEED 4 dia metal elbow Pipe compound or PTFE tape Flexible gas line connector Duct clamps 2 or Spring clamps...

Страница 6: ...nect shall not exceed 4 feet Use a new CSA International approved flexible gas supply line Never reuse old flexible connectors Install an individual manual shut off valve within 6ft of the dryer in ac...

Страница 7: ...ER TO THE GAS SUPPLY cont Open the gas shut off valve F Apply pipe compound or PTFE tape to all male threads Shut Off Valve Plugged Tapping CONNECTING THE DRYER TO THE GAS SUPPLY Install a female 3 8...

Страница 8: ...down grounding will reduce the risk of electric shock by providing a path of least resistance for electric current This dryer uses a cord having an equipment grounding conductor and a grounding plug T...

Страница 9: ...ntify the plug type as per the house receptacle before purchasing line cord Flat blade screwdriver Phillips screwdriver 4 Cover Plate Kit WE49X22606 if needed Disconnect power supply before servicing...

Страница 10: ...or electrical shock For electrical connections using a power cord GROUNDING INSTRUCTIONS For a grounded cord connected dryer This dryer must be grounded In the event of a malfunction or breakdown gro...

Страница 11: ...breaker s 30 amp or remove the dryer s circuit fuse at the electrical box 2 Be sure the dryer cord is unplugged from the wall receptacle 3 Remove the power cord cover located at lower back 4 Install...

Страница 12: ...harp objects For best drying performance 1 Slide one end of the duct over the clothes dryer outlet pipe 2 Secure the duct with a clamp 3 With the dryer in its permanent position extend the duct to its...

Страница 13: ...45 elbows will be treated like one 90 elbow For the side exhaust installations add one 90 elbow to the chart For every additional 90 elbow reduce the allowable vent system length by 10 feet When calcu...

Страница 14: ...rflow and should require little or no maintenance to prevent clogging Wall caps must be installed at least 12 above ground level or any other obstruction with the opening pointed down SEPARATION OF TU...

Страница 15: ...ved previously to secure the duct in place through the tab on the appliance base ADDING ELBOW AND DUCT FOR EXHAUST TO RIGHT ELECTRIC MODELS ONLY OR LEFT SIDE OF CABINET Preassemble 4 elbow with 4 duct...

Страница 16: ...up before pressing Power Otherwise the display will not come on The dryer is now ready for use 3 Connect standard metal elbows and ducts to complete the exhaust system Cover back opening with the plat...

Страница 17: ...rewdriver Tape tipped putty knife Small flat blade screwdriver Before you start Unplug the dryer from its electrical outlet Choose the REVERSING THE DOOR instructions A or B for your model A REVERSING...

Страница 18: ...d in step 3 into the lower left side screw holes and firmly tighten all 4 screws 6 Install the 4 plastic caps removed in step 1 into the 4 right side front panel holes NOTE To return the door to the o...

Страница 19: ...oles 2 on the left and 2 on the right 3 Loosen each top hinge screw on right side Remove the door and place it on a protective flat surface to avoid any damage Plastic Cap 4 Left side of front panel L...

Страница 20: ...you finish Plug the dryer back into its electrical outlet Door Hang door and tighten screws B REVERSING THE DOOR GLASS PANEL DOOR MODELS cont 6 Remove and swap the 2 plastic caps and the 2 hinges 7 Ro...

Страница 21: ...GAS NICAMENTE ANTES DE COMENZAR Lea estas instrucciones por completo y con detenimiento IMPORTANTE Guarde estas instrucciones para el uso de inspectores el ctricos locales IMPORTANTE Cumpla con todos...

Страница 22: ...t Manguera corta adaptador en Y arandelas y WE1M847 Manguera Larga O POR SEPARADO WE1M847 Manguera Larga y WE1M848 Manguera Corta Instrucciones de instalaci n Incline la secadora de costado y saque lo...

Страница 23: ...de la secadora y las paredes adyacentes u otras superficies es 0 sobre ambos lados 1 sobre el frente 1 la parte trasera 1 superior Para mejorar el desempe o se sugiere un espacio libre de 1 2 en cada...

Страница 24: ...sta que est firmemente asentada 5 Aseg rese de que la arandela de goma plana se encuentra en su posici n y coloque una manguera de entrada de agua de 4 a 6 pies de largo puede ser necesario comprarla...

Страница 25: ...as y el material del conducto V lvula de cierre MATERIALES NECESARIOS Codo de metal de 4 di metro Compuesto o PTFE cinta para tuber as Conector de tuber a de gas flexible Abrazaderas de tuber a 2 o ab...

Страница 26: ...est aprobada por CSA International Nunca vuelva a usar conectores flexibles viejos Instale una v lvula de cierre manual individual dentro de 6 pies de la secadora en acuerdo con el C digo Nacional de...

Страница 27: ...do del gas F Aplique compuesto para tuber a o cinta PTFE en todas las roscas macho V lvula de apagado Toma a rosca C MO CONECTAR LA SECADORA AL SUMINISTRO DE GAS Instale un codo hembra NPT de 3 8 al f...

Страница 28: ...ecadora est instalada en su posici n final Si el circuito tiene un recept culo de 2 clavijas es responsabilidad del propietario de reemplazarlo con un recept culo de 3 clavijas debidamente conectado a...

Страница 29: ...e enchufe seg n el tomacorriente de la vivienda antes de comprar el cable 4 Placa de cubierta Kit WE49X22606 si fuese necesario Destornillador de lados planos Destornillador Phillips Desconecte el sum...

Страница 30: ...s Consulte a un electricista calificado o personal o representantes del servicio t cnico si tiene dudas de que el electrodom stico se encuentre conectado a tierra apropiadamente NO modifique el enchuf...

Страница 31: ...senchufado del tomacorriente 3 Retire la tapa del cable de corriente ubicada en la parte inferior trasera 4 Instale un alivio de tensi n de 3 4 pulgadas reconocido por UL en el orificio de entrada del...

Страница 32: ...a como en la pared Los codos permiten que la secadora pueda estar junto a la pared sin que se aplaste ni se doble el conducto de transici n maximizando el rendimiento del secado Evite que la tuber a s...

Страница 33: ...ser considerados como un codo de 90 Para el escape lateral agregue un codo de 90 a la tabla Para cada codo adicional de 90 reduzca en 10 pies la longitud permisible del sistema de escape En el c lculo...

Страница 34: ...obstrucci n con la abertura apuntando hacia abajo SEPARACI N DE CURVAS Para un mejor desempe o separe todas las curvas con 4 pies de conducto recto como m nimo incluyendo la distancia entre la ltima...

Страница 35: ...modelos a el ctrico Izquierda Parte inferior Vuelva a conectar la porci n cortada A del conducto a la caja del ventilador Aseg rese de que el conducto m s corto se encuentre alineado con la leng eta d...

Страница 36: ...A A TRAV S DE LA PARTE INFERIOR DEL GABINETE NIVELE LA SECADORA ENCHUFE LA SECADORA 1 CONFIGURACI N FINAL 2 INICIO DE LA SECADORA Presione el bot n Power Encendido NOTA Si la secadora ha sido expuesta...

Страница 37: ...ta cubierta con cinta Destornillador de punta plana peque a Antes de Comenzar Desenchufe la secadora del tomacorriente A INVERSI N DE LA PUERTA MODELOS DE PUERTA S LIDA 1 Abra la puerta aproximadament...

Страница 38: ...agujeros inferiores del lado izquierdo y apriete firmemente los cuatro tornillos 6 Instale las cuatro tapas de pl stico retiradas en el paso 1 en los 4 agujeros del panel frontal derecho NOTA Para reg...

Страница 39: ...s mismas en posiciones opuestas Tapa de pl stico 4 Lado izquierdo del panel frontal Placa ciega Placa de refuerzo 3 Afloje cada tornillo de la bisagra superior en el lado derecho Retire la puerta y co...

Страница 40: ...a enchufar la secadora en la salida el ctrica Puerta Sostenga la puerta y ajuste los tornillos Tapa de pl stico 4 Lado derecho del panel frontal B INVERSI N DE LA PUERTA MODELOS CON PANEL DE CRISTAL...