Installation Preparation

PREPARE ELECTRICAL WIRING

#282 French

FOR PERSONAL SAFETY: 

Remove house fuse or open circuit breaker 

before beginning installation. Do not use 

an extension cord or adapter plug with 

this appliance.

#282 French

The improper connection of the equipment

grounding conductor can result in a risk 

of electric shock. Check with a qualified 

electrician or service representative if you 

are in doubt that the appliance is properly 

grounded.

For models equipped with power cord:

 Do not modify the plug 

provided with the appliance; if it will not fit the outlet, have a 
proper outlet installed by a qualified technician.

Cabinet Preparation and Wire Routing

• The wiring may enter the opening from either side, rear or the 

fl oor within the shaded area.

• Cut a 1-1/2" maximum diameter hole to admit the electrical 

cable. Cable direct connections may pass through the same 
hole as the drain hose and hot water line, if convenient. If 
cabinet wall is metal, the hole edge must be covered with 
a bushing.

Note:

 Power cords with plug must pass through a separate 

hole.

Electrical Connection to Dishwasher

Electrical connection is on the right front of dishwasher.
• For cable direct connections the cable must be routed as 

shown in Figure E. Cable must extend a minimum of 24" from 
the rear wall.

• For power cord connections, install a 3-prong grounding type 

receptacle in the sink cabinet rear wall, 6" min. or 18" max. 
from the opening, 6" to 18" above the fl oor.

4

Figure E

WARNING

WARNING

Electrical Requirements

• This appliance must be supplied with 120V, 60Hz., and 

connected to an individual properly grounded branch circuit, 
protected by a 15 or 20 ampere circuit breaker or time delay 
fuse.

• Wiring must be 2 wire with ground and rated for 75°C (176°F).
• If the electrical supply does not meet the above 

requirements, call a licensed electrician before proceeding.

Grounding Instructions–Cable Direct

This appliance must be connected to a grounded metal, 
permanent wiring system, or an equipment grounding 
conductor must be run with the circuit conductors and be 
connected to the equipment grounding terminal or lead on the 
appliance.

Grounding Instructions–Power Cord Models

This appliance must be grounded. In the event of a malfunction 
or breakdown, grounding will reduce the risk of electric shock 
by providing a path of least resistance for electric current. 
This appliance is equipped with a cord having an equipment 
grounding conductor and a grounding plug. The plug must 
be plugged into an appropriate outlet that is installed and 
grounded in accordance with all local codes and ordinances.

�����

���

��

���

���������

�������

�������

���������

����������

��������

������

�����

�����������

�����������

���

��

����������

��������

����

���������

Содержание GSD6000 Series

Страница 1: ...gloves safety glasses or goggles should be worn READ CAREFULLY KEEP THESE INSTRUCTIONS IMPORTANT Observe all governing codes and ordinances Note to Installer Be sure to leave these instructions for th...

Страница 2: ...in hose if required Waste tee for house plumbing if applicable Electrical cable or power cord if applicable Screw type hose clamps Strain relief for electrical connection Hand shut off valve recommend...

Страница 3: ...rain installation depends on the following questions Do local codes or ordinances require an air gap Do local codes or ordinances require an air gap Is waste tee less than 18 above floor Is waste tee...

Страница 4: ...the cable must be routed as shown in Figure E Cable must extend a minimum of 24 from the rear wall For power cord connections install a 3 prong grounding type receptacle in the sink cabinet rear wall...

Страница 5: ...increase the spring tension If the door rises when released decrease the tension Note Increase or decrease tension as shown Adjust both springs to the same tension setting to correct balance Figure G...

Страница 6: ...ISHWASHER DRAIN PORT Skip this step if drain hose has been pre installed In this step you will need the drain hose and clamp set aside in Step 1 Stand dishwasher upright Place drain hose clamp over 1...

Страница 7: ...k Stop pushing when the dishwasher extends about 6 inches forward of adjacent cabinets Make sure drain hose is not kinked under the dishwasher and there is no interference with the water line and wiri...

Страница 8: ...ssary service charges Carefully open and close the door to ensure the door panel is not catching or rubbing on the cabinet frame 8 STEP 14 LEVEL DISHWASHER IMPORTANT Dishwasher must be level for prope...

Страница 9: ...4 Door panel and or control panel must not hit cabinets or countertop Fasten the dishwasher to the underside of the countertop with the 2 Phillips special head screws Refer to Figure T Make certain sc...

Страница 10: ...on with hose clamps Figure X Figure Y Secure the drain hose to the air gap waste tee or disposer with clamps Note TOTAL DRAIN HOSE LENGTH MUST NOT EXCEED 10 FEET FOR PROPER DRAIN OPERATION Method 2 Bu...

Страница 11: ...0 Check door alignment with tub If door hits tub level Check door alignment with tub If door hits tub level dishwasher See Steps 14 and 15 Pull lower rack out about halfway Check to be sure it does Pu...

Страница 12: ...If leaks are found turn off power at the breaker and correct plumbing as necessary Restore power after corrections are made See Steps 7 and 17 Open dishwasher door and make sure most of the water Ope...