49-6000245 Rev. 2
21
TROUBLESHOOTING
Status Light Codes
Status Light
Condition
Action
OFF
Gas control/thermostat turned off
Follow instructions in Lighting and Shutdown, page 7,
to turn on the gas control/thermostat.
Pilot burner not lit
Follow instructions in Lighting and Shutdown, page 7,
to light the pilot burner.
Power supply insufficient
Confirm that the thermopile wire connectors are firmly
attached to the gas control/thermostat.
Inspect thermopile wires and replace if damaged.
Inspect pilot light assembly.
Constantly lit
Pilot light recently extinguished and thermopile
cooling
Gas control/thermostat knob recently turned off
Follow instructions in Lighting and Shutdown, page 7,
to light the pilot burner.
1 blink
every 3 seconds
Normal
Gas control/thermostat knob in pilot position and
pilot burner lit
Turn gas control/thermostat knob to desired setting.
2 blinks
every 3 seconds
Low thermopile power, but pilot burner is lit
Confirm that the thermopile wire connectors are firmly
attached to the gas control/thermostat.
If fault still occurs, call a qualified service technician.
4 blinks
every 3 seconds
High water temperature limit reached
Call a qualified service technician.
5 blinks
every 3 seconds
Water temperature sensor failed
Call a qualified service technician.
7 blinks
every 3 seconds
Gas control/thermostat failed
Call a qualified service technician.
8 blinks
every 3 seconds
Faulty pilot flame signal
Pilot light is out. Wait 10 minutes and attempt to
relight the pilot flame. If error continues, call a
qualified service technician.
9 blinks every 3
seconds
Defective door thermistor
Call a qualified service technician
10 blinks every 3
seconds
Chamber has exceded maximum temperature
and system has shut down
Call a qualified service technician