– 35 –
The collar port redirects the air going into the ice
box for optimum ice production.
Collar Port Removal
1. Remove the top ice port gasket from the door.
2. Push up and in on the tab located inside the
port of the door (viewed from outside the
door).
3. Remove the ice bucket.
4. Pull collar port out from inside the door.
The access cover conceals the electrical
connections for the icemaker and auger motor
as well as provide the ice box thermistor with a
mounting location.
Icemaker Access Cover Removal
1. Remove the ice bucket.
2. Remove three Phillips-head screws.
3. Unclip the thermistor from the backside of the
cover.
The main board uses the thermistor to monitor
ice box temperatures and regulate the icemaker
blower fan. To access the thermistor, remove the
icemaker access cover.
To test or replace the thermistor, follow the
steps under
Thermistor Replacement
in the
Thermistors
section of this service guide.
Collar Port
Icemaker Access Cover
Ice Box Thermistor
Содержание GFE24JBL