Outlet Control Backup Thermostat
The outlet control backup
thermostat opens at
165°F and will
automatically reset at
155°F.
To remove the outlet control backup thermostat:
1. Remove the drum.
2. Remove the Phillips-head screw and the thermostat moisture shield from
the front frame.
3. Disconnect the 2 wires from the outlet control backup thermostat.
4. Remove the Phillips-head screw that attaches the outlet control backup
thermostat to the blower housing.