Special inStallation RequiRementS 

Specification Revised 10/15

GFDn110eD 

GE

®

 Series 7.0 Cu. Ft. Super Capacity Front Load Electric Dryer 

For answers to your Monogram, GE Profile

™ 

Series  

or GE

®

 Series appliance questions, visit our website  

at geappliances.com or call GE Answer Center

®

 

service, 800.626.2000.

Dryer exhausting information 

– Metal duct only.

For complete information, see installation instructions packed with your dryer.

Ducting materials: 

For best performance, this dryer should be vented with 4" diameter  

all rigid metal exhaust duct. If rigid metal duct cannot be used, then UL-listed flexible metal  
(semi-rigid) ducting can be used (Kit WX08X10077). In special installations, it may be necessary  

to connect the dryer to the house vent using a flexible metal (foil-type) duct. A UL-listed flexible 

metal (foil-type) duct may be used ONLY in installations where rigid metal or flexible metal  
(semi-rigid) ducting cannot be used AND where a 4" diameter can be maintained throughout the 

entire length of the transition duct. Please see installation instruction packed with your dryer for 

complete instructions when using flexible metal (foil type) ducting. 

exhaust length calculation:

1.  Determine the number of 90° turns needed for your installation. If you exhaust to the  
  side or bottom of dryer, add one turn.
2.  The maximum length of 4'  rigid (aluminum or galvanized) duct which can be tolerated is  
  shown in the table.
  A turn of 45° or less may be ignored. Two 45° turns within the duct length should be  
  treated as a 90° elbow. 
  A turn over 45° should be treated as a 90° elbow.
Dryers 

must

 be exhausted to the outside.

caution: 

For personal safety do not terminate exhaust into a chimney, under any enclosed house 

floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard or moisture 
could cause damage. Never terminate the exhaust into a common duct or plenum with a kitchen 
exhaust, since the combination of lint and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. 
The wall cap must also be located at least 12" above the ground or any other obstruction with the 
opening pointed down.

for more information on venting kits anD accessories, please call 

1-800-ge-cares.

Best performance

Maximum length  
of 4" dia 

rigid  

metal

 duct

Exhaust hood type

Domestic dryer models 

Number 

of 90° 

turns

a

4"  

opening

B

2-1/2" 

opening

GE Front Load Long Vent 7.0 

cu. ft. capacity electric dryer 

(GFDL)

0

200 ft.

175 ft.

1

185 ft.

165 ft.

2

175 ft.

155 ft.

3

165 ft.

145 ft.

4

155 ft.

135 ft.

5

145 ft.

125 ft.

Long Vent 6.0 - 8.0 cu. ft.  

capacity electric & gas dryers 

(GTDL and GTV)

0

150 ft.

125 ft.

1

135 ft.

115 ft.

2

125 ft.

105 ft.

3

115 ft.

95 ft.

4

105 ft.

85 ft.

5

95 ft.

75 ft.

Long Vent 7.0 cu. ft. capacity 

electric & gas (GTD42, GTD45, 

GTD65, GTX42 and GTX60)

0

120 ft.

90 ft.

1

100 ft.

75 ft.

2

85 ft.

65 ft.

3

70 ft.

55 ft.

4

60 ft.

45 ft.

5

55 ft.

35 ft.

All 6.0 - 8.3 cu. ft. capacity 

models electric and gas dryers 

(GFDS, GFDR, GFDN, GTDS, 

GTDN, GHDN, GHDS, GTDP, 

GLDP, GTD, HTDP, HTDX)

0

90 ft.

60 ft.

1

60 ft.

45 ft.

2

45 ft.

35 ft.

3

35 ft.

25 ft.

4

25 ft.

15 ft.

DCVH480

0

90 ft.

60 ft.

1

60 ft.

45 ft.

2

45 ft.

35 ft.

3

35 ft.

25 ft.

All 3.6 cu. ft. (DSKS, DSKP)

electric dryers

0

46 ft.

37 ft.

1

37 ft.

30 ft.

2

30 ft.

22 ft.

3

23 ft.

15 ft.

Laundry Center GUD27

0

56 ft.

42 ft.

1

48 ft.

34 ft.

2

40 ft.

26 ft.

3

32 ft.

18 ft.

Laundry Center GUD24

0

43 ft.

36 ft.

1

33 ft.

26 ft.

2

24 ft.

16 ft.

A

B

2-1/2

4

GE Dryer Vent

A

B

2-1/2

4

GE Dryer Vent

A

Dryer exhausting information—use metal  

Duct only vertical anD horizontal Ducting

Listed by 

Underwriters 

Laboratories

Содержание GFDN110ED

Страница 1: ...s 4 way via rear right left and bottom Circuit Requirements An individual properly grounded branch circuit protected by a 30 amp circuit breaker or a time delay fuse is required Note Dryer wall outlet must be located within 36 of service cord entry and accessible when dryer is mounted in position Installation Information For complete information see installation instructions packed with your dryer...

Страница 2: ...se ventilated and must contain a minimum of 60 sq in of open area equally distributed If this closet contains both a washer and a dryer doors must contain a minimum of 120 sq in of open area equally distributed No other fuel burning appliance shall be installed in the same closet with a gas dryer Bathroom or Bedroom Installation The dryer MUST be exhausted to the outdoors The installation must con...

Страница 3: ...nclosed house floor crawl space or into an attic since the accumulated lint could create a fire hazard or moisture could cause damage Never terminate the exhaust into a common duct or plenum with a kitchen exhaust since the combination of lint and grease could create a fire hazard Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts bird nesting etc The wall cap must al...

Страница 4: ...s continually monitor temperature with a sensor bar that measures moisture to prevent over drying Speed Dry quickly dries items and small loads for families on the go eDry option energy saving option reduces dry temperatures on select cycles without sacrificing performance 4 heat settings provide the right temperature for the right drying needs 6 dry cycles additional cycles for your clothes dryin...

Отзывы: