Earth Fault Alarm

Inverters sold in Australia and New Zealand will also alarm as following when Isolation Fail occurs.

1. The buzzer in the inverter will sound for 1minute. If the problem persists, the buzzer willsound 
every 30 min.

2. After adding the inverter to Power Sight, the alarm information will be emailed to the customers 
via Power Sight.

7 Technical Parameters & Block Diagram

7.1 Technical Parameters

GEP12-L-10

15600

800

200~650
360~600

180
370

30 or 26

*1

37.5 or 33

*1

0
3
2

 

12000
12000
12000
12000
12000
12000

220, 3L/N/PE or 3L/PE

176~242

50/60

47.5~51.5/57~61.8

31.5

160

60

31.5

<3%

98.0%
97.7%

GEP15-L-10

19500

800

200~650
360~600

180
370

30 or 26

*1

37.5 or 33

*1

0
3
2

15000
15000
15000
15000
15000
15000

220, 3L/N/PE or 3L/PE

176~242

50/60

47.5~51.5/57~61.8

40.0

160

60

39.4

~1 (Adjustable from 0.8 leading to 0.8 lagging)

<3%

98.0%
97.7%

Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated

Type II
Type II

Optional
Optional
Optional

30~60 (60 °C for outdoor unconditioned with solar effects.)

0~100%

3000

Smart Fan Cooling

LED, LCD (Optional), WLAN+APP

RS485, WiFi, USB, PLC (Optional)

Modbus-RTU

 SunSpec compliant

GEP20-L-10

26000

800

200~650
360~600

180
370

30 or 26

*1

37.5 or 33

*1

0
3
2

20700
20700
20700
20700
20700
20700

220, 3L/N/PE or 3L/PE

176~242

50/60

47.5~51.5/57~61.8

54.5

160

60

54.3

<3%

98.0%
97.7%

Technical Data

Input (DC

Max. Input Power (W)
Max. Input Voltage (V)
MPPT Operating Voltage Range (V)
MPPT Voltage Range at Nominal Power (V)
Start-up Voltage (V)
Nominal Input Voltage (V)
Max. Input Current per MPPT (A)
Max. Short Circuit Current per MPPT (A)
Max. Backfeed Current to The Array (A)
Number of MPP Trackers
Number of Strings per MPPT

Output (AC

Nominal Output Power (W)
Nominal Output Apparent Power (VA)
Max. AC Active Power (W)
Max. AC Apparent Power (VA)
Nominal Power at 40

 (W)

Max Power at 40

 (Including AC Overload) (W)

Nominal Output Voltage (V)
Output Voltage Range (V)
Nominal Output Frequency (Hz)
AC Grid Frequency Range (Hz)
Max. Output Current (A)
Max. Output Fault Current (Peak and Duration) (A/ms)
Inrush Current (Peak and Duration) (A/us)
Nominal Output Current (A)
Power Factor
Max. Total Harmonic Distortion

Efficiency

Max. Efficiency
Europen Efficiency

Protection

PV String Current Monitoring
PV Insulation Resistance Detection
Residual Current Monitoring
PV Reverse Polarity Protection
Anti-islanding Protection
AC Overcurrent Protection
AC Short Circuit Protection
AC Overvoltage Protection
DC Switch
DC Surge Protection
AC Surge Protection
AFCI
Remote Shutdown
PID Recovery

General Data

Operating Temperature Range (

)

Relative Humidity
Max. Operating Altitude (m

Cooling Method 
Display
Communication
Communication protocols

1. Disconnect the DC switch, take off DC connector, measure the voltage 

of PV string.

2. Plug in DC connector, and reconnect DC switch.

3.If the voltage is less than 70 V, please check the PV string configura-

tion.

4. If the voltage is higher than 180V and still no display please contact 

local service office.

1. Disconnect the DC connector.

2. Reconnect the DC connector.

3. If the problem still exists, please call the local service office.

Type of fault

Troubleshooting

Relay-check Failure

DCI High

EEPROM R/W Failure

SPI Failure

DC Bus High

GFCI Failure

No display

Inverter
Failure

Others

When sunlight is insuffcient, the PV inverter may continuously start and shut down due 
to insufficient power generation by the PV panel, this will not damage the inverter. If the 
problem still exists, please call the local service office.

Содержание GEP12-L-10

Страница 1: ...UAL Global Sales Service Network GE is a registered trademark of General Electric Company and is used under license by GoodWe Technologies Co Ltd No 90 Zijin Rd New District Suzhou 215011 China www ge...

Страница 2: ...7 5 System Operation 21 5 1 LCD Panel And LED 21 5 2 User Interface Introduction 22 5 3 System Configuration 25 5 4 Precaution For Initial Startup 30 5 5 Setting Inverter Parameters via App 31 5 6 Mon...

Страница 3: ...work All detailed work related safety warnings and notes will be specified at the critical points in corresponding chapter All installation and electrical work must only be performed by qualified per...

Страница 4: ...ons which will lead to potential injury to people and damage to inverters Static electricity may damage electronic components Appropriate method must be adopted to prevent such damage to the inverter...

Страница 5: ...ter provides standard interface RS485 WIFI for communication Inverters also provide running recode data display parameter configuration via LCD panel For the main block diagram please refer to chapter...

Страница 6: ...ommunication Terminal Grounding Screw Expansion Bolt Safe Screw Connecting Terminal Grounding AC Cover OT Terminal Insulation Sleeve WiFi Module WiFi communication Or without LCD Quick Installation In...

Страница 7: ...values The Upward part The downward part The front part Both sides Interval 200mm 500mm 500mm 600mm 1200mm 500mm 1200mm 600mm 600mm 500mm 300mm The Upward part The downward part The front part Both si...

Страница 8: ...low these steps to connect the utility and inverter 7 If the diameter of the cable does not match the terminal or if the cable is aluminum cable please contact after sales service Two mounting holes i...

Страница 9: ...et of a suitable length with a wire stripper Output Current 31 5A 40A 54 5A 40A 43 3A 48A 53 3A 80A 96A 80A 96A Inverter Model GEP12 L 10 GEP15 L 10 GEP20 L 10 GEP25 10 GEP29 9 10 GEP30 10 GEP36 10 GE...

Страница 10: ...not met The GEP series has three PV input area PV1 input PV2 input PV3 input each with MPPT tracker therefore the three PV input can be different with each other including different type of modules di...

Страница 11: ...zlogger Pro manual Remote shutdown is only for European installations in compliance with European safety requirements A remote shutdown device is not provided by manufacturer DRED should be connected...

Страница 12: ...ion This function is only applicable for WiFi model for specific configurations please refer to WiFi LAN Configuration Instruction in the attachment and you can also refer to the description of Demo V...

Страница 13: ...ive On Fault occurred OFF No fault Status Indicator Green green green red light respectively corresponds to 5 2 User Interface Introduction Communication information icon GPRS and WiFi show the signal...

Страница 14: ...Fi 22 93 3kWH 4 E TOTAL E DAY 01 01 2020 00 00 00 CARBON Fault Utility Loss 0 0kWH Basic Advanced WiFi 22 105 3kWH 4 E TOTAL E DAY 01 01 2020 00 00 00 Fault WiFi Con guration 22 Basic Advanced 01 01 2...

Страница 15: ...0 00 Fault Country Code Holland Northlreland ChinaHigher France 50Hz France 60Hz WiFi 22 01 01 2020 00 00 00 Fault Language WiFi 22 01 01 2020 00 00 00 Fault Data Time WiFi 22 01 01 2020 00 00 00 Faul...

Страница 16: ...i 22 01 01 2020 00 00 00 Normal Adv Settings HVRT Grid Type Password Factory Data Reset WiFi 22 01 01 2020 00 00 00 Normal Adv Settings HVRT Grid Type Password Factory Data Reset WiFi 22 01 01 2020 00...

Страница 17: ...0 6 0 4 0 2 0 4 6 8 10 12 14 16 18 20 Month Year Basic Advanced 01 01 2020 00 00 00 Fault WiFi Con guration 22 Basic Advanced 01 01 2020 00 00 00 Normal WiFi Con guration 22 01 01 2020 00 00 00 Norma...

Страница 18: ...local service office 1 Disconnect the DC switch take off DC connector check PV string voltage check if it exceeds the input voltage in inverter specification 2 If it does please reconfigurate PV panel...

Страница 19: ...ber of MPP Trackers Number of Strings per MPPT Output AC Nominal Output Power W Nominal Output Apparent Power VA Max AC Active Power W Max AC Apparent Power VA Nominal Power at 40 W Max Power at 40 In...

Страница 20: ...rent A Max Output Fault Current Peak and Duration A ms Inrush Current Peak and Duration A us Nominal Output Current A Power Factor Max Total Harmonic Distortion Efficiency Max Efficiency Europen Effic...

Страница 21: ...T Output AC Nominal Output Power W Nominal Output Apparent Power VA Max AC Active Power W Max AC Apparent Power VA Nominal Power at 40 W Max Power at 40 Including AC Overload W Nominal Output Voltage...

Страница 22: ...pment in an industrial installation Category IV applies to equipment permanently connected at the origin of an installation upstream of the main distribution board For example electricity meters prima...

Страница 23: ...PV plant Caution Before maintenance please disconnect the AC breaker rst and then disconnect DC breaker Wait 5 minutes until the residual voltage has been released 8 1 Clearing The Fan Series inverte...

Отзывы: