Dip Switch Setting Chart

Chart Assumes 

LED Code of

“XX5”

Dip 

Switch 

Setting

GECLPS4

GECLPS3

Notes

6 LEDs/Ft. 

 (20/m)

5 LEDs/Ft.  

(16/m)

6 LEDs/Ft. 

 (20/m)

5 LEDs/Ft.  

(16/m)

Matches 

Bin Code

16 ft. 

(4.8m) 

20 ft. 

(6.1m)

64 ft. 

(19.5m)

80 ft. 

(24.4m)

Recommended 

for Optimal 

Performance

-1

20 ft. 

(6.1m) 

24 ft. 

(7.3m)

80 ft. 

(24.4m)

96 ft. 

(29.3m)

Intensity of the 

Tetra Strip will 

be reduced by

approximately 

10% to 20%

+1

12 ft.

 (3.7m) 

16 ft. 

(4.8m)

48 ft. 

(14.6m)

64 ft. 

(19.5m)

Intensity of the 

Tetra Strip will 

be increased by

approximately 

10% to 20%

With power off, set the correct dip switch according to the Dip Switch Setting Chart (see below for detailed explanation).
NOTE: 

For proper operation, verify that only one switch is set to the “ON” position.

Replace the dip switch cover and perform a quick test by turning the system on to ensure the channel letter LEDs are lit.

Dip Switch Settings

The following chart indicates the Tetra Strip load that can be placed on the Power Supply based on the character code on the LED and 

the dip switch setting chosen. For example, when the Tetra Strip is marked with the character code HN3, the “3” on the dip switch can 

be set to the ON position to achieve 

neon-equivalent performance. At this 

setting, the GECLPS3 power supply can 

support up to 64 ft. (19.5m) of the 6 LED 

per foot Tetra Strip. If you change the 

dipswitch setting and flip #2 switch to 

the ON position, the power supply can 

support up to 80 ft. (24.4m) of Tetra 

Strip. The footage guidelines vary based 

on the type of Tetra Strip being used. 

The charts below provide the footage 

requirements for each Tetra Strip type.

CAUTION:

 Avoid setting the dip switch 

to the ON position with any setting 

not listed in the chart unless stated 

otherwise. Exceeding maximum load of 

any 4 load banks will cause the power 

supply shut down Once the exceeded 

load is removed, cycle the input power 

will restart the power supply.

Wire AC line to LED driver(s) in 

accordance with the applicable 

local, state, and country electrical 

codes. Connect black to black 

or brown, white to white or blue, 

and green to green using 18 AWG 

(0.82mm

2

) wire connectors. 

5

Connect the red stripe wire (+) 

of the LED control module to the 

red wire (+) of the power supply. 

Connect the white wire (-) of the 

LED control module to the black or 

blue wire (-) of the power supply.

Connect each LED control module 

output lead pair to each Tetra LED 

module supply lead pair using 

UL certified wire connectors. Cap 

each unused output lead with a UL 

certified wire connector.  

6

7

AC line

Black to black 

or brown (-)

LED driver

LED control module

Green to 

green

White to white 

or blue (+)

Red (+)

Red stripe (+)

To LED modules

Cap unused leads

Inline connector

White (-)

Black or blue (-) 

Character Code 

of Tetra

® 

Strip

Dip Switch 

Setting

XX1

1

XX2

2

XX3

3

XX4

4

XX5

5

XX6

6

WARNING:

 Do not connect outputs 

in series or parallel.

Содержание GECLPS3-2

Страница 1: ...e in dry and damp locations The grounding and bonding of the LED Driver shall be done in accordance with National Electric Code NEC Article 600 Follow all National Electric Codes NEC and local codes These products are only suitable for connection to a circuit from a Class 2 power source These products have not been evaluated for use when connected to a power source that does not comply with Class ...

Страница 2: ...ied personnel in accordance with applicable local state and country electrical codes Make sure the removal of lighting equipment does not compromise the integrity of the sign body i e water intrusion Fill in all holes 0 5 in 13 mm or smaller with the appropriate amount of rated caulk or sealant For holes greater than 0 5 in 13 mm use an aluminum or zinc coated steel patch with rivets and sealant G...

Страница 3: ...D per foot Tetra Strip If you change the dipswitch setting and flip 2 switch to the ON position the power supply can support up to 80 ft 24 4m of Tetra Strip The footage guidelines vary based on the type of Tetra Strip being used The charts below provide the footage requirements for each Tetra Strip type CAUTION Avoid setting the dip switch to the ON position with any setting not listed in the cha...

Страница 4: ...nections in accordance with local state or country regulations NOTE The grounding and bonding of the power supply and overall sign shall be done in accordance with National Electric Code NEC Article 600 SIGNXXX R071514 GE Lighting Solutions 1 888 MY GE LED www gelighting com 1 8 8 8 6 9 4 3 5 3 3 GE Lighting Solutions LLC is a subsidiary of the General Electric Company Tetra is a trademark of GE L...

Отзывы: