Condenser Fan Not Running
Note:
•
Compressor and condensor fan should always operate at the same time.
• When no voltage at main control board, make certain to check for shorted fan motor (less
than 1k ohm between white and red or white and yellow). A shorted fan motor will
damage the replacement main board.
Check fan for obstruction.
Unplug the refrigerator to
reset main control board.
Warm freezer thermistor
to 70 F. Reconnect
power and set
temperature controls to 5
and 5. Recheck voltage.
Is voltage correct?
Replace condenser
fan motor.
Repair wiring between
main control board and
condenser fan motor.
Unplug J2
connector on the
main control board.
Check for 13 VDC
between pins J2-3
and J2-5 and 11-13
VDC between pins
J2-3 and J2-8.
Is voltage correct for
both?
At the condenser
fan connector,
check for 13 VDC
from the red to
white wire and 11-
13 VDC from white
to yellow wire.
Is voltage correct
for both?
YES
Replace main
control board.
YES
NO
NO
NO
Adjust settings and allow
24 hours to stabilize.
YES