GE Ericsson MASTR II Скачать руководство пользователя страница 4

ALIGNMENT PROCEDURE

STEP

METER

POSITION

TUNING

CONTROL

METER

READING

PROCEDURE

100 WATT PA

13.

Terminate the output power J2 with a 50 ohm watt
meter capable of reading 150 watts.

14.

Key the transmitter and set R11 (control board) for
100 watt output.

15.

Read and record the DC voltage at feed through
cap C5. This reading can be used for future output
checks.

DO NOT EXCEED 100 watts of output power.

16.

Using the test set connected to the Exciter
metering jack and the transmitter keyed, detune
Z102 10 percent from its peak reading. The output
PWR should remain constant at 100 watts. This
check insures ample operating margin.

17.

Tune Z102 back to a peak reading on the test set.

Under no conditions should the Exciter be
tuned using the PA output as a level indicator.
The PA control circuits mask Exciter tuning
procedures.

NOTE

851-870 MHz, 100 WATT TRANSMITTER

Issue 2

ALIGNMENT PROCEDURE

STEP

METER

POSITION

TUNING

CONTROL

METER

READING

PROCEDURE

EXCITER

1.

B

(PHASE MOD)

L103, T101

See Procedure

Tune L103 for maximum meter reading. Then tune
T101 for a dip (small) in meter reading.

2.

C

(MULT-1)

T102 and T103

See Procedure

Tune T102 for maximum meter reading, then tune

T103 for a dip in meter reading.

3.

D

(MULT-2)

T104 and T105

See Procedure

Tune T104 for maximum meter reading and then

tune T105 for a dip in meter reading.

4.

F

(MULT-3)

T106 and C157

See Procedure

Tune T106 for maximum meter reading and then
tune C157 for a dip in meter reading.

5.

G

(MULT-4)

C159 and Z101

See Procedure

Tune C159 for maximum meter reading, and then
tune Z101 for a dip in meter reading.

6.

A

(REL OUTPUT)

Z102

Maximum

Tune Z102 for maximum meter reading.

7.

B

(PHASE MOD)

L103

Maximum

Tune L103 for maximum meter reading.

8.

C

(MULT-1)

T101 and T102

Maximum

In order, tune T101 and T102 for maximum meter
reading.

9.

D

(MULT-2)

T103 and T104

Maximum

Tune T103 and then T104 for maximum metering

reading.

10.

F

(MULT-3)

T105 and T106

Maximum

Tune T105 and then T106 for maximum meter

reading.

11.

G

(MULT-4)

C157 and C159

Maximum

Tune C157 and then C159 for maximum meter

reading.

12.

D

(INPUT DRIVE)

Z101, Z102

Maximum

Test set connected to Exciter metering jack. Then
alternately tune Z101 and Z102 for maximum
meter reading.

When aligning transmitter, proceed as in-
structed below. DO NOT retune a previously
tuned control unless specifically directed to
do so.

NOTE

LBI-31985

LBI-31985

3

Содержание Ericsson MASTR II

Страница 1: ...multipliers to provide the station operating frequency The PA assembly uses 3 RF amplifier stages to drive a two transistor power output circuit Each stage employs matching networks consisting of discrete components and strip line technology The RF output power is fed to the an tenna through a circulator containing a low pass filter The PA assembly includes a power control module The power control...

Страница 2: ...or thereby preventing overmodu lation while preserving intelligibility TEST EQUIPMENT 1 An audio oscillator GE Model 4EX6A10 2 A frequency modulation monitor 3 Voltmeter 4 GE Test Set Model 4EX3A11 or 4EX8K12 5 Frequency Counter 6 Oscilloscope 7 50 ohm Wattmeter PROCEDURE 1 Connect the audio oscillator and the meter across audio input terminals J10 Green Hi and J11 Black Lo on GE Test Set and conn...

Страница 3: ...t 875 MHz 1 PPM is 875 Hz With an operating frequency of 851 MHz set the oscilla tor for a reading of 374 Hz 0 44 x 851 Hz higher than the licensed operating frequency If a negative correction factor is obtained at temperatures above 27 5 C set the oscillator for the indicated PPM lower than the licensed operating fre quency TRANSMITTER ALIGNMENT EQUIPMENT REQUIRED 1 GE Test Set Model 4EX3A11 or T...

Страница 4: ...er reading 2 C MULT 1 T102 and T103 See Procedure Tune T102 for maximum meter reading then tune T103 for a dip in meter reading 3 D MULT 2 T104 and T105 See Procedure Tune T104 for maximum meter reading and then tune T105 for a dip in meter reading 4 F MULT 3 T106 and C157 See Procedure Tune T106 for maximum meter reading and then tune C157 for a dip in meter reading 5 G MULT 4 C159 and Z101 See P...

Страница 5: ...103 T101 Q102 Q103 T101 ICOM Q102 Q103 T101 ICOM C MULT 1 Q104 T103 T101 T102 Q104 T101 T102 Q104 T103 D MULT 2 Q105 T105 T103 T104 Q105 T103 T104 Q105 T105 F MULT 3 Q106 C155 Q106 T105 T106 Q106 T105 T106 L105 G MULT 4 Q107 Z101 Z102 Q107 C159 C157 Q107 C159 C157 Z101 Z102 A REL OUTPUT Q107 Q107 C174 CR102 R154 R153 851 870 MHz 100 WATT TRANSMITTER Issue 1 LBI 31985 LBI 31985 4 ...

Страница 6: ...This page intentionally left blank LBI 31985 LBI 31985 5 ...