GE Dresser Series B3 Скачать руководство пользователя страница 5

 

5

JP2

JP4

A

B

C

E

F

D

1 2 3 4 5

1 2 3 4

P1+

P1-

P2+

P2-

DRAIN

A

B

C

E

F

D

ISOL

A

TION AMPLIFIER

     ISO-2

1

4

7

10

8

9

11

12

CIRCULAR  CONNEC

TO

R

+1

-1

+2

-2

Open collector 

independant output 

channels. May be used as 

PULL UP and or

, PULL 

down. FORM A and or

FORM B r

espectively.

0 to 30VDC

0 to 50MADC

P

OWER SUPPL

Y INPUT FOR 

ISOL

A

TION

AMPLIFIERS

.

20 to 250V

A

C

20 to 125VDC

3 w

atts

8.2V

10ma max

8.2V

10ma max

+

-

  

HA

ZARDOUS  ARE

A

NON HA

ZARDOUS ARE

A

     TUR

CK

   IM1-12Ex-T

     (shown)

FORM A pulse  connections  transmitted to Isolation  Amplifiers. S

tandar

d BL

UE WIRE 

Intrinsic safety  connections.

All intrinsically safe wiring 

must be seperated fr

om 

any other safe zone wiring 

by at least 2 inches in a 

separate panduit

.

Use TUR

CK IM1-12Ex-T single 

channel, IM1-22 E

X-R Dual channel 

Isolation Amplifiers or

, equiv

alent 

which ar

e capable of high speed 

switching r

esponse.

HA

ZARDOUS ARE

A INST

ALL

A

TIONS IN 

CANAD

A MUST BE INST

ALLED IN 

A

C

C

ORD

ANCE WITH THE CANADIAN 

ELECTRICAL C

ODE (CEC) P

A

R

T 1. 

HA

ZARDOUS ARE

A INST

ALL

A

TIONS IN 

THE UNITED ST

A

TES MUST BE 

INST

ALLED IN A

C

C

ORD

ANCE WITH THE 

NA

TIONAL ELECTRIC C

ODE (NEC).

Either Normally open or Normally  closed output may be selected 

with the, "NO/NC" ISO-AMP 

switch in the fr

ont of these unts. 

Pulse form may be selected per 

requir

ements of the logging 

system used.

ISOL

A

TION AMPLIFIER

     ISO-1

1

4

7

10

8

9

11

12

+1

-1

+2

-2

Open collector 

independant output 

channels. May be used as 

PULL UP and or

, PULL 

down. FORM A and or

FORM B r

espectively.

0 to 30VDC

0 to 50MADC

P

OWER SUPPL

Y INPUT FOR 

ISOL

A

TION

AMPLIFIERS

.

20 to 250V

A

C

20 to 125VDC

3 w

atts

+

-

     TUR

CK

   IM1-12Ex-T

     (shown)

P

O-1(+)

P

O-1(-)

P

O-2(+)

P

O-2(-)

ES3

INTRINSIC

S

AFE

T

Y

 

GR

OUND

BUSS

Figur

e 5

 - W

iring Diagram for hazar

dous locations.

Содержание Dresser Series B3

Страница 1: ...GE Oil Gas Dresser Series B3 Meter with ES3 Electronic Temperature Compensator Circular Pulse Output Connector Installation Supplement imagination at work ...

Страница 2: ... screen is either Compensated Volume or Non Compensated Volume depending on customer configuration a This parameter is the home default screen b After a time out of approximately 30 seconds the home screen always will appear 2 Repeat the swiping motion of the magnet across the words Roots ES3 Index and the screens will appear in sequential order as shown in Table 1 Note Using the Dresser MeterWare ...

Страница 3: ...der to arrive at compensated volume COMPENSATED RESIDUAL Compensated Residual Shows extended compensated volume data beyond the value shown in the compensated volume screen NON COMPENSATED RESIDUAL Non compensated Residual Shows extended non compensated volume data beyond the value shown in the non compensated volume screen BASE T Base Temperature Displays base temperature as entered by the user B...

Страница 4: ...ed a Vout 30V b Iout 50ma Refer to Figure 5 for proper wiring in hazardous locations WARNING Ensure properly licensed trained professionals are used to install equipment if installed in hazardous locations containing explosive atmospheres All local codes and standards shall be maintained during installation WARNING Products certified as intrinsically safe installations shall be Installed put into s...

Страница 5: ...X R Dual channel Isolation Amplifiers or equivalent which are capable of high speed switching response HAZARDOUS AREA INSTALLATIONS IN CANADA MUST BE INSTALLED IN ACCORDANCE WITH THE CANADIAN ELECTRICAL CODE CEC PART 1 HAZARDOUS AREA INSTALLATIONS IN THE UNITED STATES MUST BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE NEC Either Normally open or Normally closed output may be selected ...

Страница 6: ...able on the Advanced screen as shown in Figure 7 Figure 7 Advanced screen in Dresser MeterWare software After clicking Test Pulse Outputs a screen appears as shown in Figure 8 Click Yes to proceed with the pulse output test For further information refer to the Dresser MeterWare Manual Figure 8 Send test Pulses screen in Dresser MeterWare software GEA19694 IS B3E 2 12 GE Oil Gas 16240 Port Northwes...