2-6
D30 Line Distance Protection System
GE Multilin
2.1 INTRODUCTION
2 PRODUCT DESCRIPTION
2
The order codes for the reduced size vertical mount units with the process bus module are shown below.
MOUNT/COATING
H
|
|
|
|
|
|
|
|
Horizontal (19” rack)
A
|
|
|
|
|
|
|
|
Horizontal (19” rack) with harsh environmental coating
FACEPLATE/ DISPLAY
C
|
|
|
|
|
|
|
English display
D
|
|
|
|
|
|
|
French display
R
|
|
|
|
|
|
|
Russian display
A
|
|
|
|
|
|
|
Chinese display
P
|
|
|
|
|
|
|
English display with 4 small and 12 large programmable pushbuttons
G
|
|
|
|
|
|
|
French display with 4 small and 12 large programmable pushbuttons
S
|
|
|
|
|
|
|
Russian display with 4 small and 12 large programmable pushbuttons
B
|
|
|
|
|
|
|
Chinese display with 4 small and 12 large programmable pushbuttons
K
|
|
|
|
|
|
|
Enhanced front panel with English display
M
|
|
|
|
|
|
|
Enhanced front panel with French display
Q
|
|
|
|
|
|
|
Enhanced front panel with Russian display
U
|
|
|
|
|
|
|
Enhanced front panel with Chinese display
L
|
|
|
|
|
|
|
Enhanced front panel with English display and user-programmable pushbuttons
N
|
|
|
|
|
|
|
Enhanced front panel with French display and user-programmable pushbuttons
T
|
|
|
|
|
|
|
Enhanced front panel with Russian display and user-programmable pushbuttons
V
|
|
|
|
|
|
|
Enhanced front panel with Chinese display and user-programmable pushbuttons
W
|
|
|
|
|
|
|
Enhanced front panel with Turkish display
Y
|
|
|
|
|
|
|
Enhanced front panel with Turkish display and user-programmable pushbuttons
POWER SUPPLY
(redundant supply must
be same type as main supply)
H
|
|
|
|
|
|
125 / 250 V AC/DC power supply
H
|
|
|
|
|
RH
125 / 250 V AC/DC with redundant 125 / 250 V AC/DC power supply
L
|
|
|
|
|
|
24 to 48 V (DC only) power supply
L
|
|
|
|
|
RL
24 to 48 V (DC only) with redundant 24 to 48 V DC power supply
PROCESS BUS MODULE
|
81
|
|
|
|
Standard 4CT/4VT
DIGITAL INPUTS/OUTPUTS
XX
XX
XX
XX
XX
No Module
4A
4A
|
4 Solid-State (no monitoring) MOSFET outputs
4B
4B
|
4 Solid-State (voltage with optional current) MOSFET outputs
4C
4C
|
4 Solid-State (current with optional voltage) MOSFET outputs
4D
4D
|
16 digital inputs with Auto-Burnishing
4L
4L
|
14 Form-A (no monitoring) Latching outputs
67
67
|
8 Form-A (no monitoring) outputs
6A
6A
|
2 Form-A (voltage with optional current) and 2 Form-C outputs, 8 digital inputs
6B
6B
|
2 Form-A (voltage with optional current) and 4 Form-C outputs, 4 digital inputs
6C
6C
|
8 Form-C outputs
6D
6D
|
16 digital inputs
6E
6E
|
4 Form-C outputs, 8 digital inputs
6F
6F
|
8 Fast Form-C outputs
6G
6G
|
4 Form-A (voltage with optional current) outputs, 8 digital inputs
6H
6H
|
6 Form-A (voltage with optional current) outputs, 4 digital inputs
6K
6K
|
4 Form-C and 4 Fast Form-C outputs
6L
6L
|
2 Form-A (current with optional voltage) and 2 Form-C outputs, 8 digital inputs
6M
6M
|
2 Form-A (current with optional voltage) and 4 Form-C outputs, 4 digital inputs
6N
6N
|
4 Form-A (current with optional voltage) outputs, 8 digital inputs
6P
6P
|
6 Form-A (current with optional voltage) outputs, 4 digital inputs
6R
6R
|
2 Form-A (no monitoring) and 2 Form-C outputs, 8 digital inputs
6S
6S
|
2 Form-A (no monitoring) and 4 Form-C outputs, 4 digital inputs
6T
6T
|
4 Form-A (no monitoring) outputs, 8 digital inputs
6U
6U
|
6 Form-A (no monitoring) outputs, 4 digital inputs
6V
6V
|
2 Form-A outputs, 1 Form-C output, 2 Form-A (no monitoring) latching outputs, 8 digital inputs
INTER-RELAY
COMMUNICATIONS
(select a maximum of 1 per unit)
2A
C37.94SM, 1300nm single-mode, ELED, 1 channel single-mode
2B
C37.94SM, 1300nm single-mode, ELED, 2 channel single-mode
2E
Bi-phase, single channel
2F
Bi-phase, dual channel
2G
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 1 Channel
2H
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 2 Channels
72
1550 nm, single-mode, LASER, 1 Channel
73
1550 nm, single-mode, LASER, 2 Channel
74
Channel 1 - RS422; Channel 2 - 1550 nm, single-mode, LASER
75
Channel 1 - G.703; Channel 2 - 1550 nm, Single-mode LASER
76
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 1 Channel
77
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 2 Channels
7A
820 nm, multi-mode, LED, 1 Channel
7B
1300 nm, multi-mode, LED, 1 Channel
7C
1300 nm, single-mode, ELED, 1 Channel
7D
1300 nm, single-mode, LASER, 1 Channel
7E
Channel 1 - G.703; Channel 2 - 820 nm, multi-mode
7F
Channel 1 - G.703; Channel 2 - 1300 nm, multi-mode
7G
Channel 1 - G.703; Channel 2 - 1300 nm, single-mode ELED
7H
820 nm, multi-mode, LED, 2 Channels
7I
1300 nm, multi-mode, LED, 2 Channels
7J
1300 nm, single-mode, ELED, 2 Channels
7K
1300 nm, single-mode, LASER, 2 Channels
7L
Channel 1 - RS422; Channel 2 - 820 nm, multi-mode, LED
7M
Channel 1 - RS422; Channel 2 - 1300 nm, multi-mode, LED
7N
Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, ELED
7P
Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, LASER
7Q
Channel 1 - G.703; Channel 2 - 1300 nm, single-mode LASER
7R
G.703, 1 Channel
7S
G.703, 2 Channels
7T
RS422, 1 Channel
7W
RS422, 2 Channels
Table 2–6: D30 ORDER CODES (REDUCED SIZE VERTICAL UNITS WITH PROCESS BUS)
D30
-
*
**
- *
*
* - F
**
- H
**
- M
**
-
P/R
**
Reduced Size Vertical Mount (see note regarding P/R slot below)
BASE UNIT
D30
|
|
|
|
|
|
|
|
|
Base Unit
CPU
T
|
|
|
|
|
|
|
|
RS485 and Three Multi-mode fiber 100Base-FX (SFP with LC)
U
|
|
|
|
|
|
|
|
RS485 with 1 100Base-T Ethernet, SFP RJ-45 + 2 100Base-FX Ethernet, multimode, SFP with LC
V
|
|
|
|
|
|
|
|
RS485 with 3 100Base-T Ethernet, SFP with RJ-45
SOFTWARE
00
|
|
|
|
|
|
|
No Software Options
03
|
|
|
|
|
|
|
IEC 61850; not available for Type E CPUs
A0
|
|
|
|
|
|
|
CyberSentry Lvl 1
A3
|
|
|
|
|
|
|
CyberSentry Lvl 1 and IEC 61850
B0
|
|
|
|
|
|
|
IEEE 1588
B3
|
|
|
|
|
|
|
IEEE 1588 and IEC 61850
D0
|
|
|
|
|
|
|
IEEE 1588 and CyberSentry Lvl 1
D3
|
|
|
|
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and IEC 61850
MOUNT/COATING
V
|
|
|
|
|
|
Vertical (3/4 rack)
B
|
|
|
|
|
|
Vertical (3/4 rack) with harsh environmental coating
FACEPLATE/ DISPLAY
F
|
|
|
|
|
English display
D
|
|
|
|
|
French display
R
|
|
|
|
|
Russian display
A
|
|
|
|
|
Chinese display
K
|
|
|
|
|
Enhanced front panel with English display
M
|
|
|
|
|
Enhanced front panel with French display
Q
|
|
|
|
|
Enhanced front panel with Russian display
U
|
|
|
|
|
Enhanced front panel with Chinese display
L
|
|
|
|
|
Enhanced front panel with English display and user-programmable pushbuttons
N
|
|
|
|
|
Enhanced front panel with French display and user-programmable pushbuttons
T
|
|
|
|
|
Enhanced front panel with Russian display and user-programmable pushbuttons
V
|
|
|
|
|
Enhanced front panel with Chinese display and user-programmable pushbuttons
W
|
|
|
|
|
Enhanced front panel with Turkish display
Y
|
|
|
|
|
Enhanced front panel with Turkish display and user-programmable pushbuttons
Table 2–5: D30 ORDER CODES (HORIZONTAL UNITS WITH PROCESS BUS)
D30
-
*
**
- *
*
* - F
**
- H
**
- M
**
- P
**
- U
**
- W/X
**
Full Size Horizontal Mount
Содержание D30D00HCHF8AH6AM6BP8BX7A
Страница 10: ...x D30 Line Distance Protection System GE Multilin TABLE OF CONTENTS...
Страница 52: ...2 22 D30 Line Distance Protection System GE Multilin 2 2 SPECIFICATIONS 2 PRODUCT DESCRIPTION 2...
Страница 96: ...3 44 D30 Line Distance Protection System GE Multilin 3 3 DIRECT INPUT OUTPUT COMMUNICATIONS 3 HARDWARE 3...
Страница 126: ...4 30 D30 Line Distance Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4...
Страница 374: ...5 248 D30 Line Distance Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5...
Страница 398: ...6 24 D30 Line Distance Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6...
Страница 410: ...7 12 D30 Line Distance Protection System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7...
Страница 444: ...9 24 D30 Line Distance Protection System GE Multilin 9 5 FAULT LOCATOR 9 THEORY OF OPERATION 9...
Страница 576: ...B 102 D30 Line Distance Protection System GE Multilin B 4 MEMORY MAPPING APPENDIX B B...
Страница 616: ...D 10 D30 Line Distance Protection System GE Multilin D 1 IEC 60870 5 104 PROTOCOL APPENDIX D D...
Страница 628: ...E 12 D30 Line Distance Protection System GE Multilin E 2 DNP POINT LISTS APPENDIX E E...
Страница 636: ...F 8 D30 Line Distance Protection System GE Multilin F 3 WARRANTY APPENDIX F F...
Страница 646: ...x D30 Line Distance Protection System GE Multilin INDEX...