Terminal Block
Cover
• This luminaire has been packed to ensure no damage
during transit. Inspect to confirm.
• Do not impact or stack luminaire after unpacking.
UNPACKING/HANDLING
1
• This luminaire is provided with means for mounting on
2-3/8 inch (60mm) to 3 inch (76mm) outside diameter
pole tops.
• Feed the power supply leads through the slipfitter
wire access hole as the fixture is installed on the pole.
• Orient canopy screw or latch toward street and level
luminaire by adjusting the 3 mounting screws, and
tighten.
•
CAUTION: Tighten mounting screws to 15-20 ft-lbs.
(20-27 N-m).
• Remove shipping ties from wire way in the rear upright.
MOUNTING
2
WIRING
3
•
NOTE: Make all electrical connections in accordance
with the National Electrical Code and any applicable
local code requirements including grounding.
•
NOTE: Verify that supply voltage is correct by comparing
it to nameplate.
• Remove cover at base of unit.
• Connect all 3 power leads to the terminal block as
noted in table 1. Torque to 35 in-lbs
• Replace cover.
TABLE 1. Terminal Board Connections
Terminal Board Position
Supply Lead
L1
High Line
G
Ground
N/L2
Low Line/Neutral
Risk of injury or damage. Unit will fall if not installed
properly. Follow installation instructions.
Shipping Ties
Cupola
Mounting Screws
DO NOT torque bolts greater than 20 ft-lbs. Damage
may occur.
WARNING
WARNING
Risk of injury. LED light source achieves full intensity
immediately upon being powered on. Do not look directly
at LED light source while energized during install.
WARNING