If

 

a

 

GE

 

product

 

malfunctions,

 

please

 

verify

 

the

 

following:

 

1.

 

Software

 

version

 

resident

 

on

 

the

 

product

2.

 

System

 

configuration

3.

 

Electrical

 

connections

4.

 

Jumper

 

or

 

configuration

 

options

5.

 

Boards

 

are

 

fully

 

inserted

 

into

 

their

 

proper

 

connector

 

location

6.

 

Connector

 

pins

 

are

 

clean

 

and

 

free

 

from

 

contamination

7.

 

No

 

components

 

or

 

adjacent

 

boards

 

were

 

disturbed

 

when

 

inserting

 

or

 

remov

ing

 

the

 

board

 

from

 

the

 

chassis

8.

 

Quality

 

of

 

cables

 

and

 

I/O

 

connections

If

 

products

 

must

 

be

 

returned,

 

contact

 

GE

 

for

 

a

 

Return

 

Material

 

Authorization

 

(RMA)

 

Number.

 

This

 

RMA

 

Number

 

must

 

be

 

obtained

 

prior

 

to

 

any

 

return

 

from

  

Customer

 

Care.

GE

 

Customer

 

Care

 

is

  

available

 

at:

 

1

800

433

2682

 

in

 

North

 

America,

 

 

or

 

+1

780

401

7700

 

for

 

international

 

calls.

  

Or,

 

visit

 

our

 

website

 

www.ge

ip.com.

Maintenance Prints

User

 

level

 

repairs

 

are

 

not

 

recommended.

 

The

 

drawings

 

and

 

diagrams

 

in

 

this

 

manual

 

are

 

for

 

reference

 

purposes

 

only.

Содержание CompactPCI VMIACC-7055 Series

Страница 1: ...000 Rev D Installation Guide VMIACC 7055 ACC 7055RC CompactPCI Rear Transition Board for the VMICPCI 7055 CPCI 7055RC THE ACC 7055RC IS DESIGNED TO MEET THE EUROPEAN UNION EU RESTRICTION OF HAZARD OUS SUBSTANCE ROHS DIRECTIVE 2002 95 EC CURRENT REVISION ...

Страница 2: ...tered with an approved Producer Compliance Scheme PCS and subject to suitable contractual arrangements being in place will ensure WEEE is processed in accordance with the requirements of the WEEE Directive GE will evaluate requests to take back products purchased by our customers before August 13 2005 on a case by case basis A WEEE management fee may apply ...

Страница 3: ...DE Header 11 1 4 2 PIM Site Connector and Pinout J10 12 1 5 PIM Site Connector and Pinout J14 13 1 5 1 Serial Port Connectors and Pinouts P9 and P10 14 1 5 2 Jumper Configuration for Different Serial Modes 14 1 5 3 CompactFlash Connector and Pinout P6 15 1 5 4 CompactFlash Master and Slave Jumper E4 16 1 5 5 Gigabit LAN Port Connectors and Pinouts J6 and J7 16 1 5 6 J3 Connector Pinout 18 1 5 7 J5...

Страница 4: ...7055 ACC 7055RC 9 Figure 1 4 LED Definitions 10 Figure 1 5 P8 40 pin IDE Header Internal 11 Figure 1 6 PIM Site J10 Connector 12 Figure 1 7 PIM Site J14 Connector 13 Figure 1 8 Serial Port Connectors P9 and P10 14 Figure 1 9 Serial Header Signals 15 Figure 1 10 CompactFlash Connector P6 15 Figure 1 11 CompactFlash Master and Slave Jumper E4 16 Figure 1 12 Ethernet Connector 17 Figure 1 13 J3 Conne...

Страница 5: ...14 Connector Pinout 13 Table 1 4 Serial Port P9 P10 Pinout 14 Table 1 5 Jumper Configurations for Different Serial Modes 14 Table 1 6 CompactFlash P6 Pinout 15 Table 1 7 CompactFlash Master and Slave Jumper E4 16 Table 1 8 Ethernet Connectors LAN1 and LAN2 Pinouts 17 Table 1 9 J3 Connector Pinout 18 Table 1 10 J5 Connector Pinout 19 ...

Страница 6: ...unted in the rear I O area of the chassis and provides associated signals from the front mounted SBC The signals are routed to the backplane through the J3 and J5 connectors The J4 connector is used for alignment only and has no electrical connections The VMIACC 7055 ACC 7055RC boards are full 6U form factor boards with a CompactFlash connector an internal IDE header two COM ports two LAN ports op...

Страница 7: ...CC 7055RC Rear Transition Board LEDs 10 100 1000 Ethernet 2 10 100 1000 Ethernet 1 IDE Connector VMIACC 7055 J5 J4 J3 PIM Site J10 J14 LAN 1 LAN 2 COM 1 COM 2 CompactFlash IDE PMC1 I O Seconda r y IDE RS232 or RS422 485 1 RS232 or RS422 485 2 ACC 7055RC ...

Страница 8: ...2 Kbyte Flash 64 Mbyte Flash R TC 32 Kbyte NVRAM 10 100 1000 LAN Gbit PH Y T wo Single or One Double Wide PMC Site PMC Site 1 I O 64 bit Device Bus 64 bit 66 MHz PCI Bus RJ45 COM 0 RS232 IPMI U A RT RJ45 w mag RGMII T T L PCI PCI Secondary IDE RGMII RGMII Gbit PH Y Gbit PH Y Mag Mag PICMG 2 16 PICMG 2 16 64 bit 66 MHz PCI 32 bit 33 MHz 64 bit CPLD 64 bit 66 MHz PCI Bus Dev Bus PCI to PCI Bridge 32...

Страница 9: ...s on the VMIACC 7055 ACC 7055RC s PIM site using the J10 and J14 connectors Figure 1 3 Installing the PIM on the VMIACC 7055 ACC 7055RC V M I P I M 5 7 9 7 VM IAC C 7055 P8IDE 40 Pin Header J5 J4 J3 P9 COM1 P10 COM2 COM2 COM1 J14 J10 P I M J6 LAN 1 P6 CompactFlash E5 E6 E7 E8 E4 J7 LAN 2 ...

Страница 10: ...tes link speed Yellow LED indicates 100Base TX Green LED indicates 1000Base T and an unlit LED indicates 10Base T Ethernet Status Indicators All three Pwr LEDs should be illuminated Green once power is applied to the board When IDE is activated the IDE ACT LED flashes Otherwise LED is unlit Power and IDE Status Indicators Ethernet Serial ports ports PIM site Status Indicators ...

Страница 11: ...hem must be set as a slave See CompactFlash Master and Slave Jumper E4 on page 16 for instructions on how to set the CompactFlash as a master slave NOTE An 80 conductor cable is required for IDE interfaces above Ultra ATA 66 Figure 1 5 P8 40 pin IDE Header Internal Table 1 1 40 pin IDE Header Pinout Pin Signal Pin Signal 1 IDES_RESET 2 GND 3 IDES_ D 7 4 IDES_D 8 5 IDES_ D 6 6 IDES_D 9 7 IDES_D 5 8...

Страница 12: ...N C 2 N C 33 N C 34 GND 3 N C 4 N C 35 N C 36 N C 5 5 0VDC 6 N C 37 5 0VDC 38 N C 7 N C 8 N C 39 N C 40 N C 9 N C 10 3 3VDC 41 N C 42 3 3VDC 11 N C 12 N C 43 N C 44 N C 13 GND 14 N C 45 GND 46 N C 15 N C 16 N C 47 N C 48 N C 17 N C 18 GND 49 N C 50 GND 19 N C 20 N C 51 N C 52 N C 21 5 0VDC 22 N C 53 5 0VDC 54 N C 23 N C 24 N C 55 N C 56 N C 25 N C 26 3 3VDC 57 N C 58 3 3VDC 27 N C 28 N C 59 N C 60...

Страница 13: ...PMC1_IO 9 10 PMC1_IO 10 41 PMC1_IO 41 42 PMC1_IO 42 11 PMC1_IO 11 12 PMC1_IO 12 43 PMC1_IO 43 44 PMC1_IO 44 13 PMC1_IO 13 14 PMC1_IO 14 45 PMC1_IO 45 46 PMC1_IO 46 15 PMC1_IO 15 16 PMC1_IO 16 47 PMC1_IO 47 48 PMC1_IO 48 17 PMC1_IO 17 18 PMC1_IO 18 49 PMC1_IO 49 50 PMC1_IO 50 19 PMC1_IO 19 20 PMC1_IO 20 51 PMC1_IO 51 52 PMC1_IO 52 21 PMC1_IO 21 22 PMC1_IO 22 53 PMC1_IO 53 54 PMC1_IO 54 23 PMC1_IO 2...

Страница 14: ...ccordingly as well NOTE Defaults are in bold NOTE To configure the serial ports for loopback mode S1 on the VMICPCI 7055 CPCI 7055RC Product Manual Document Number 500 657055 000 for details will need pins 6 and 8 relating to COM 1 and COM 2 respectively placed in the ON position Table 1 4 Serial Port P9 P10 Pinout RS232 RS422 485 Pin Signal Name Pin Signal Name 1 DCD 1 RXD 2 RXD 2 RXD 3 TXD 3 TXD...

Страница 15: ...al Name Pin Signal Name Pin Signal Name 1 GND 14 GND 27 IDES_D 11 40 N C 2 IDES_D 3 15 GND 28 IDES_D 12 41 IDES_RESET 3 IDES_D 4 16 GND 29 IDES_D 13 42 IDES_IORDY 4 IDES_D 5 17 GND 30 IDES_D 14 43 IDES_DMARQ 5 IDES_D 6 18 IDES_DA2 31 IDES_D 15 44 IDES_DMACK 6 IDES_D 7 19 IDES_DA1 32 IDES_CS3 45 HD_ACTA 7 IDES_CS1 20 IDES_DA0 33 N C 46 IDES_CBLIO 8 GND 21 IDES_D 0 34 IDES_DIOR 47 IDES_D 8 9 GND 22 ...

Страница 16: ...ter and Slave Jumper E4 1 5 5 Gigabit LAN Port Connectors and Pinouts J6 and J7 Although the two Gigabit Ethernet connectors are available on the VMIACC 7055 ACC 7055RC they can only be used when the VMICPCI 7055 CPCI 7055RC has a value of ʹ1ʹ in the optionsʹ D field which allows for Ethernet via CompactPCI J3 not PICMG 2 16 compatible Table 1 7 CompactFlash Master and Slave Jumper E4 Master Slave...

Страница 17: ...ation 17 Figure 1 12 Ethernet Connector Table 1 8 Ethernet Connectors LAN1 and LAN2 Pinouts LAN1 and LAN2 Pin No Signal Name 1 MDI 0 2 MDI 0 3 MDI 1 4 MDI 2 5 MDI 2 6 MDI 1 7 MDI 3 8 MDI 3 Connector Opening Pin 1 Top View ...

Страница 18: ...BI_DD GND 16 LPB_BI_DA LPB_BI_DA2 GND LPB_BI_DC LPB_BI_DC GND 15 LPB_BI_DB LPB_BI_DB2 GND LPB_BI_DD LPB_BI_DD GND 14 GND GND GND GND GND GND 13 SP2_RTS SP1_RI SP2_DSR SP2_DCD SP2_CTS GND 12 SP1_RTS SP2_DTR VCC_5 0 SP1_CTS GND GND 11 SP2_TXB SP2_RXD SP1_DTR SP1_DCD LPA_BI_DC GND 10 SP1_TXB SP1_RXD SP1_DSR SP2_RI LPA_BI_DD2 GND 9 GND GND N C GND LPB_BI_DC2 GND 8 LPA_BI_DA2 LPA_BI_DA2 SP2_ACTIVE LPA_...

Страница 19: ... PMC1_IO 28 PMC1_IO 27 PMC1_IO 26 GND 16 PMC1_IO 35 PMC1_IO 34 PMC1_IO 33 PMC1_IO 32 PMC1_IO 31 GND 15 PMC1_IO 40 PMC1_IO 39 PMC1_IO 38 PMC1_IO 37 PMC1_IO 36 GND 14 PMC1_IO 45 PMC1_IO 44 PMC1_IO 43 PMC1_IO 42 PMC1_IO 41 GND 13 PMC1_IO 50 PMC1_IO 49 PMC1_IO 48 PMC1_IO 47 PMC1_IO 46 GND 12 PMC1_IO 55 PMC1_IO 54 PMC1_IO 53 PMC1_IO 52 PMC1_IO 51 GND 11 PMC1_IO 60 PMC1_IO 59 PMC1_IO 58 PMC1_IO 57 PMC1_...

Страница 20: ...cent boards were disturbed when inserting or remov ing the board from the chassis 8 Quality of cables and I O connections If products must be returned contact GE for a Return Material Authorization RMA Number This RMA Number must be obtained prior to any return from Customer Care GE Customer Care is available at 1 800 433 2682 in North America or 1 780 401 7700 for international calls Or visit our...

Страница 21: ...n evaluated to and have met the requirements for compliance to the following standards International Compliance EN55022 1998 CISPR 22 1997 IEC61000 4 2 IEC61000 4 3 IEC61000 4 4 IEC61000 4 5 IEC61000 4 6 European Union CE Mark BS EN55024 1998 w A1 01 A2 03 BS EN55022 Class A United States FCC Part 15 Subpart B Section 109 Class A Australia New Zealand AS NZS CISPR 22 2002 Class A Canada ICES 003 C...

Страница 22: ...nvironment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CAUTION Changes ...

Страница 23: ...S ARE PROVIDED AS IS WITH NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WHETHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTIES OF DESIGN MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ALL OTHER LIABILITY ARISING FROM RELIANCE UPON ANY INFORMATION CONTAINED HEREIN IS EXPRESSLY DISCLAIMED GE Intelligent Platforms Information Centers Americas 1 800 322 3616 or 1 256 880 0444 Asia Paci...

Отзывы: