![GE CDT865SxJ0 Series Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/ge/cdt865sxj0-series/cdt865sxj0-series_technical-service-manual_4154270048.webp)
– 48 –
Diagnostics are aided with the addition of a green
Service LED on the machine control board that
indicates the status of the control board. To view the
LED, disconnect power and place the main control
in service position (under To Access Main Control
Board, found on the next page), then repower the
dishwasher to view the Service LED.
Diagnosing the main control and UI control are
covered in this section. Many components can
be checked from the main control, which can be
accessed with the door on or removed, if needed.
Some connectors are located through the bottom
cover to allow easy access to AC supply connector,
door harness and RJ45 connector.
WARNING: GE Factory Service Technicians are
REQUIRED to follow Lockout / Tagout (LOTO) 6
Step Process prior to beginning repair.
Single Speed Motor Main Control
Variable Speed Motor Main Control
Heat
Connector
AC Power Connector (backside of board)
DC Power
Connector
Service
LED
Drain & Circ. Connector
Personality
Jumper
Blink Pattern
Meaning
1x per 3 seconds Dishwasher in not running a
cycle, select a cycle and press
Start.
2x per 3 seconds Dishwasher is in Delay Start
and waiting to start a cycle.
The cycle will begin once the
delay expires.
3x per 3 seconds Dishwasher is running a cycle.
4x per 3 seconds Dishwasher is paused, close
the door and press Start to
resume the cycle.
5x per 3 seconds Dishwasher has completed a
cycle and the Clean Light is on
(door has not been opened).
6x per 3 seconds Dishwasher is in Demo Mode.
To exit Demo Mode, press and
hold Start and Heated Dry for
5 seconds.
7X per 3 seconds Current Sense Module is
tripped. See the CSM section of
this guide.
1x per second
Communications lost between
control boards. Check
connections, replace UI or MC
as needed.
Flashing rapidly
(4x per second)
Software error, replace MC.
6WHDG\RȺ
Dishwasher is not powered,
check supply voltage, replace
MC as needed.
Steady On
UI personality not set,
communications lost between
UI and MC.
Diagnosing Electronic Control Boards
Main Control Diagnostics
DC Power Connectors
Service LED
(
Continued next page
)
Содержание CDT865SxJ0 Series
Страница 18: ...18 Inside Tub Trim Third Rack Upper Rack Main Conduit Silverware Basket Lower Rack Detergent Module Door Strike...
Страница 60: ...60 Diagnostics Strip Circuit...
Страница 90: ...90 Schematics CDT835SxJ0xx PDT825SxJ0xx and PDT835SxJ0xx...
Страница 91: ...91 CDT835SxJ0xx PDT825SxJ0xx and PDT825SxJ0xx...
Страница 92: ...92 ZDT915SxJ0xx and ZDT915SxJ0xx...