background image

CGY366SELSS 

GE Café

 Series 36" All Gas Professional Range with 6 Burners (Natural Gas)

Specification Revised 10/17

DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)

All GE Appliances ranges are equipped 

with an Anti-Tip device. The installation 

of this device is an important, required 

step in the installation of the range.

Listed by 

Underwriters 

Laboratories

For answers to your GE Appliances product questions, visit our website 
at geappliances.com or call GE Answer Center

®

 Service, 800.626.2000.

NOTE:

 Professional ranges offer a number of choices 

in size and cooktop configurations. All Professional 
Ranges are factory set for natural gas.

NOTE:

 Conversion kits are included with the range. 

High Altitude kit, WB28K10553 for operation above 
6,000 feet (for Natural and LP gas models), is also 
available. The kits must be installed by a qualified 
service technician at additional cost.

INSTALLATION INFORMATION:

 Before 

installing, consult installation instructions packed 
with product or online at geappliances.com for 
current dimensional data.
A suitable 36" or wider vent hood is required 
for installation over ranges with a grill and 
recommended for all other ranges.

ADVANCE PLANNING:

 Refer to dimensional 

drawings for appropriate placement and necessary 

clearances when planning the installation.
-  Working areas adjacent to the range should have 

18" minimum clearance between countertop and 
cabinet bottom.

-  Clearance between range and side wall or 

combustible material must be at least 12" on 
each side.

-  Installation must conform with local codes. 

In the absence of local codes, the range must 
comply with the National Fuel Gas Code, 
ANSI Z223.1-1990.

ADDITIONAL CLEARANCES:
Allow 12" minimum clearance to an adjacent wall

on each side.
Working areas adjacent to the rangetop should have

18" minimum clearance between countertop and 

the bottom of the wall cabinet.

Non-Combustible

Material

13"

max.

18"

min.

36" min.

48" minimum

to combustibles

12" minimum

each side

12" minimum

to adjacent wall

WARNING:

 Installations without a hood require 

48" minimum to combustibles. A custom hood 
installation with exposed horizontal combustible 
surfaces must have an Auto-On feature. Refer to 
hood installation instructions for specific hood 
clearances.
The surface of the entire back wall above the range 
and below the hood must be covered with a non-
combustible material such as metal, ceramic tile, 
brick, marble or other stone.

35 7/8" width

28 1/4"

35 1/4"

to

36 3/4"

height

3 1/4"

to 4 3/4"

Toekick/leg

height

Depth

to front

of door

1 1/2"

Countertop

to Cooking

Surface

CGY366SELSS

C2Y366SELSS

Отзывы: