background image

2 C

  

CUTOUT FOR DOUBLE OVENS (2 THERMAL OVENS)

NOTE:

 If the cabinet does not have a front frame and the sides are less than ¾” (1.9 cm) thick, shim 

both sides equally to establish the cutout width.

Dim.

Description

27” Double Oven

30” Double Oven with 

Pedestal

30” Double Oven 

without Pedestal

A

Cabinet Width

27” (68.6 cm)

30” (76.2 cm)

30” (76.2 cm)

B

Cutout Width

25” (63.5 cm) min.  

25

1

ø

4

” (64.1 cm) max.

28

1

ø

2

” (72.4 cm) min.  

28

5

ø

8

” (72.7 cm) max.

28

1

ø

2

” (72.4 cm) min.  

28

5

ø

8

” (72.7 cm) max.

C

Cutout Height

49

11

ø

16

” (126.2 cm) min.  

50

1

ø

8

” (127.3 cm) max.

51

13

ø

16

” (131.6 cm) min.  

51

15

ø

16

” (131.9 cm) max.

50 ¼” (127.64cm) 

D

Overlap of Oven 

Over Side Edges 

of Cutout

1” (2.5 cm)

11

ø

16

” (1.75 cm)

11

ø

16

” (1.75 cm)

E

Clearance to 

Adjacent Corners, 

Drawers, Walls, etc., 

When Door Is Open

23” (50.8 cm) min.

23” (53.3 cm) min.

23” (53.3 cm) min.

F

Overlap of Oven 

Top of Cutout

1” (2.5 cm) min.

1” (2.5 cm) min. 

(1

1

ø

4

” (3.2 cm) for PT9550, 

ZET2S and ZET2P)

1” (2.5 cm) min. 

(1

1

ø

4

” (3.2 cm) for PT9550, 

ZET2S and ZET2P)

G

Overlap of Oven 

Bottom of Cutout

1” (2.5 cm) min.

1

1

ø

4

” (3.2 cm)

1

1

ø

4

” (3.2 cm)

H

Junction Box 

Location 

8

3

ø

4

” (22.2 cm) max. 

right side only

9

1

ø

2

” (24.1 cm) max. 

right side only

9

1

ø

2

” (24.1 cm) max. 

right side only

J

Height to Bottom 

of Junction Box

44” (111.8 cm)

47” (119.4 cm)

47” (119.4 cm)

K

Recommended 

Cutout Location 

from Floor

13

1

ø

4

” (33.7 cm)

12” (30.5 cm)

12” (30.5 cm)

2 D

  

CUTOUT FOR INSTALLATION OVER A WARMING DRAWER

NOTE: 

Install the oven only with specific models listed on the label located on top of the oven.

NOTE: 

Additional clearances between cutouts may be required. Check to be sure the oven supports 

above the Warming Drawer location do not obstruct the required interior depth and height.
When installing a Warming Drawer below a single or double oven, a separate 120V, 60 HZ, properly 

grounded receptacle must be installed. Refer to installation instructions packed with  

the Warming Drawer for specific installation requirements.

Anti-Tip Block Against 

Rear Wall Per Warming 

Drawer Requirement

2" (5.1 cm) 

Min. 

Per Warming 

Drawer 

Requirement

Continue to Section 3 for DWO with Pedestal. Otherwise, continue to Section 4.

Continue to Section 3.

H

B

C

K

F

G

D

A

J

E

Junction 

Box 

Location 

(junction 

box may 

be located 

in adjacent 

cabinet)

Cutout Depth  

23-1/2”  

(59.7 cm) Min.

31-10979

07-14   GE

Содержание Cafe CKS70DP2NS1

Страница 1: ...m oven racks and heating elements Remove protective film and labels on the outer door and control panel Also remove plastic on trims and panel all tape around the oven and any shipping screws securing the oven to the base pad Open oven door and remove literature pack and oven racks Remove the bottom trim from the top of the oven It will be installed at the end of the installation process The trim ...

Страница 2: ...nly right side only 2 B CUTOUT FOR SINGLE OVENS UNDER COUNTER NOTE These ovens are only approved to be installed under the specific models as labeled on the unit Dimension Dimension Description 27 Single Oven 30 Single Oven A Cabinet Width 25 63 5 cm min 281ø2 72 4 cm min 251ø4 64 1 cm max 285ø8 72 7 cm max B Cutout Height 275ø8 70 2 cm min 271ø4 69 2 cm min 281ø8 71 4 cm max 275ø16 69 4 cm max C ...

Страница 3: ...unction Box Location 83ø4 22 2 cm max right side only 91ø2 24 1 cm max right side only 91ø2 24 1 cm max right side only J Height to Bottom of Junction Box 44 111 8 cm 47 119 4 cm 47 119 4 cm K Recommended Cutout Location from Floor 131ø4 33 7 cm 12 30 5 cm 12 30 5 cm 2 D CUTOUT FOR INSTALLATION OVER A WARMING DRAWER NOTE Install the oven only with specific models listed on the label located on top...

Страница 4: ...il on each cabinet runner or centered on opposite side of solid cabinet bottom flush with side of cabinet opening Locate each rail so that front of rail is behind front cabinet opening B Drill pilot holes and attach rails to runner or bottom of cabinet with provided hardware ...

Страница 5: ...ical Code requires that new construction not existing utilize a four conductor connection to an electric oven When installing an electric oven in new construction a mobile home recreational vehicle or an area where local codes prohibit grounding through the neutral conductor refer to the section on four conductor branch circuit connections Check with your local utilities for electrical codes which...

Страница 6: ...ral white or gray in color using a wire nut B Connect the oven red lead to the branch circuit red lead and the oven black lead to the branch circuit black lead in accordance with local codes using wire nuts C Install junction box cover Junction Box Conduit Bare Ground Red White Black Strain Relief Clamp not included Must Be Used at Junction Box Place Oven on a Support to Assist in Connecting Condu...

Страница 7: ... through the mounting holes top and bottom of the side trim for the 8 mounting screws provided B Secure the oven cabinet with the screws provided Mounting Hole Locations hole locations may vary 11 BOTTOM TRIM INSTALLATION With oven installed attach the bottom trim through its mounting holes in front vertical brace using two trim screws provided Bottom trim lip must be placed under flange of bottom...

Страница 8: ...nctionality F Close the oven door 14 FINAL INSTALLATION CHECKLIST Check to make sure the circuit breaker is closed RESET or the circuit fuses are replaced Be sure power is in service to the building Check that all packing material and tape have been removed Failure to remove these materials could result in damage to the appliance once the appliance has been turned on and surfaces have heated Remov...