210572107 Rev. C 1-08

8 of 8

www.geelectrical.com

Содержание BFL85ADW

Страница 1: ...Read all instructions before installing or using exhaust fan 2 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer 3 Before servicing or cleaning the unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on SAVE THESE INSTRUCTIONS IMPORTANT INSTRUCTIONS OPERATING MANUAL accidenta...

Страница 2: ...mper Assembly attached 2 8 Screws 2 Lockwashers 4 Mounting Rails 1 Instruction Safety Sheet 2 Choose the location for your fan To ensure the best air and sound performance it is recommended that the length of ducting and the number of elbows be kept to a minimum and that insulated hard ducting be used Larger duct sizes will reduce noise and airflow restrictions This fan will require at least 6 of ...

Страница 3: ...er detaches from unit reattach by snapping the collar back onto the unit It is designed to only fit one way SECTION 5 Wiring CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION CAUTION ALL ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE WITH LOCAL CODES ORDINANCES OR NATIONAL ELECTRICAL CODE IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING SECU...

Страница 4: ...electrical connector Make sure you leave enough wiring in the box to make the connection to the fan s receptacle 3b From where you have access to inside the fan s junction box connect the one white wire from the house to both the white wire from the fan s light receptacle and the white wire from the fan s exhaust receptacle Connect the black wire from the wall switch to both the red wire from the ...

Страница 5: ...IVE PADS OR SCOURING POWDERS Completely dry all parts before reinstalling Refer to instructions in Section 6 Completing the Installation to reinstall grill and glass light lens 2 Cleaning the Fan Assembly Wipe all parts with a dry cloth or gently vacuum the fan NEVER IMMERSE ELECTRICAL PARTS IN WATER CAUTION ALLOW BULB TO COOL BEFORE REPLACING 3 Changing the Light Bulb Disconnect power to the unit...

Страница 6: ...llation problem contact your dealer or installer You are responsible for providing adequate electrical exhausting and other connecting facilities See the Installation Instructions provided with this product for electrical exhaust and connection details Replacement of house fuses or resetting of circuit breakers Failure of the product if it is used for something other than the intended purpose of m...

Страница 7: ... Cover 5S2234001 7 1 8 B Screw 5S1299007 8 2 6 B Screw 5S1999010 9 1 Polarized Connector 5S1299008 10 1 Receptacle 5S1999001 1 14 2 3 5 6 7 15 13 12 Qty Description Replacement Part 11 1 Motor 5S2234002 12 3 Motor Mounting Screw 5S2234003 13 1 Blower Wheel 5S2234004 14 1 Cap Screw 5S2234005 15 1 Blower Housing 5S2234006 16 1 10 B Screw 5S1299009 17 1 Base 5S5234001 18 1 Mounting Screw 5S5204004 19...

Страница 8: ...210572107 Rev C 1 08 8 of 8 www geelectrical com ...