Troubleshooting Guide

Trouble

Probable Cause

Suggested Remedy

1. Fan does not operate when the switch is on.

1a. A fuse may be blown or a circuit tripped.

1a. Replace fuse or reset circuit breaker.

1b. Connector plug from motor is not plugged in.

1b. Turn off power to unit. Remove Grill and plug motor into

receptacle in housing. Restore power to unit.

1c. Wiring is not connected properly.

1c. Turn off power to unit. Check that all wires are connected.

2. Fan is operating, but air moves slower than normal.

2.

Obstruction in the exhaust ducting.

2.

Check for any obstructions in the ducting. The most common

are bird nests in the roof cap or wall cap where the fan
exhausts to the outside.

3. Fan is operating louder than normal.

3a. Motor is loose.

3a. Turn off power to unit. Remove grill and check that all screws

are fully tightened. Restore power to unit.

3b. Fan blade is hitting housing of unit.

3b. Call your dealer for service.

210572107 Rev. C 1-08

SECTION 7

Use and Care

CAUTION:

 

MAKE SURE POWER IS SWITCHED

OFF AT SERVICE PANEL BEFORE SERVICING THE UNIT.

1.

Cleaning the Grill:

 Refer to instructions in 

Section 6

Completing the Installation, to remove grill and glass
light lens. Use a mild detergent, such as dishwashing
liquid, and dry with a soft cloth. NEVER USE ANY
ABRASIVE PADS OR SCOURING POWDERS.
Completely dry all parts before reinstalling. Refer to
instructions in 

Section 6

 

Completing the Installation,

to reinstall grill and glass light lens.

2.

Cleaning the Fan Assembly:

 Wipe all parts with a

dry cloth or gently vacuum the fan. NEVER IMMERSE
ELECTRICAL PARTS IN WATER.

CAUTION:

 

ALLOW BULB TO COOL BEFORE

REPLACING.

3.

Changing the Light Bulb:

 Disconnect power to the

unit. Remove glass light lens from grill by pulling the
tension springed hook outward and sliding the glass
out of the hooks 

(Figure 13)

. Replace with a 100 watt

maximum, type A19 medium base incandescent bulb.
Refer to instructions in 

Step 6 of 

Section 6

 

Completing

the Installation, to reinstall the light lens.

5 of 8

CAUTION:

 

FAILURE TO SECURE THE GRILL MAY

RESULT IN A RATTLING OR HUMMING NOISE.

5. Install 1 - 100 watt maximum, type A19 medium base

incandescent bulb (not included).

6. The base installed in 

Step 4 has a set of mounting

hooks for the glass light lens. One of the hooks is in
a fixed position while the other has a tension spring.
The light lens has a notch on either side of the lens.
Slide one of the notches into the fixed position hook.
Then pull the other hook out until the lens is able to
fit into position and carefully release the hook to
slide the lens into the second notch. Make sure the
glass is held securely in place (

Figure 13)

.

7. Restore power and test your installation.

www.geelectrical.com

Lens

Figure 13

Lens

Hook

Tension

Spring

Notch

Содержание BFL85ADW

Страница 1: ...Read all instructions before installing or using exhaust fan 2 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer 3 Before servicing or cleaning the unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on SAVE THESE INSTRUCTIONS IMPORTANT INSTRUCTIONS OPERATING MANUAL accidenta...

Страница 2: ...mper Assembly attached 2 8 Screws 2 Lockwashers 4 Mounting Rails 1 Instruction Safety Sheet 2 Choose the location for your fan To ensure the best air and sound performance it is recommended that the length of ducting and the number of elbows be kept to a minimum and that insulated hard ducting be used Larger duct sizes will reduce noise and airflow restrictions This fan will require at least 6 of ...

Страница 3: ...er detaches from unit reattach by snapping the collar back onto the unit It is designed to only fit one way SECTION 5 Wiring CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION CAUTION ALL ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE WITH LOCAL CODES ORDINANCES OR NATIONAL ELECTRICAL CODE IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING SECU...

Страница 4: ...electrical connector Make sure you leave enough wiring in the box to make the connection to the fan s receptacle 3b From where you have access to inside the fan s junction box connect the one white wire from the house to both the white wire from the fan s light receptacle and the white wire from the fan s exhaust receptacle Connect the black wire from the wall switch to both the red wire from the ...

Страница 5: ...IVE PADS OR SCOURING POWDERS Completely dry all parts before reinstalling Refer to instructions in Section 6 Completing the Installation to reinstall grill and glass light lens 2 Cleaning the Fan Assembly Wipe all parts with a dry cloth or gently vacuum the fan NEVER IMMERSE ELECTRICAL PARTS IN WATER CAUTION ALLOW BULB TO COOL BEFORE REPLACING 3 Changing the Light Bulb Disconnect power to the unit...

Страница 6: ...llation problem contact your dealer or installer You are responsible for providing adequate electrical exhausting and other connecting facilities See the Installation Instructions provided with this product for electrical exhaust and connection details Replacement of house fuses or resetting of circuit breakers Failure of the product if it is used for something other than the intended purpose of m...

Страница 7: ... Cover 5S2234001 7 1 8 B Screw 5S1299007 8 2 6 B Screw 5S1999010 9 1 Polarized Connector 5S1299008 10 1 Receptacle 5S1999001 1 14 2 3 5 6 7 15 13 12 Qty Description Replacement Part 11 1 Motor 5S2234002 12 3 Motor Mounting Screw 5S2234003 13 1 Blower Wheel 5S2234004 14 1 Cap Screw 5S2234005 15 1 Blower Housing 5S2234006 16 1 10 B Screw 5S1299009 17 1 Base 5S5234001 18 1 Mounting Screw 5S5204004 19...

Страница 8: ...210572107 Rev C 1 08 8 of 8 www geelectrical com ...

Отзывы: