© 2019 Baker Hughes, a GE company, LLC. All rights reserved.
50
|
BHGE
Mounting the SVI FF on Rotary Valves
This procedure is used to mount the SVI FF on rotary control valves that have less than 60°
rotation, such as a Camflex or a Varimax
.
For valves that have rotation greater than 60° refer
Required Tools
The following tools are needed to complete the rotary valve installation:
3
⁄
16" Hex Key with tee handle
5
⁄
32" Hex Key
3 mm, 4 mm, 5 mm Hex Key
7
⁄
16" Wrench
To mount the SVI FF:
1. Attach the SVI FF rotary mounting bracket to the valve actuator using two (2) 5
⁄
16 - 18
UNC flat-head cap screws. Mount the SVI FF as shown in Figure 19, ATO or in Figure 20 on
page 51, ATC. In the preferred mounting position, the long end of the mounting bracket is
on your left when facing the actuator, for any position of the valve and actuator.
Figure 19 Camflex Air-To-Open Mounting (Front View)
Содержание Baker Hughes Masoneilan SVI FF
Страница 12: ...This page intentionally left blank ...
Страница 72: ...This page intentionally left blank ...
Страница 82: ...This page intentionally left blank ...
Страница 94: ...This page intentionally left blank ...
Страница 108: ...This page intentionally left blank ...
Страница 198: ...This page intentionally left blank ...
Страница 206: ...This page intentionally left blank ...
Страница 224: ...This page intentionally left blank ...
Страница 228: ...This page intentionally left blank ...
Страница 230: ...This page intentionally left blank ...
Страница 250: ...This page intentionally left blank ...
Страница 262: ...This page intentionally left blank ...
Страница 263: ......