20
May 2015
K0582 Revision B
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
K
P(
IJ
)
[7..0]
R/W-X
Bit 31–0
K
P(
IJ
)
[31..0]: Read only
0x
n..n
Number
type
float
Addresses 158-187 - Temperature coefficients
3.3.31
The temperature coefficient registers contain a total of (
I
+1)*(
J
+1) contiguous temperature
coefficients where
I
and
J
represent the values of the TP_FIT(7..0] and TT_FIT[7..0] bits of the
COEF_DIM register (address 67). Each coefficient register is bit mapped as follows:
Bit 31
Bit 30
Bit 29
Bit 28
Bit 27
Bit 26
Bit 25
Bit 24
K
T(
IJ
)
[31..24]
R/W-X
Bit 23
Bit 22
Bit 21
Bit 20
Bit 19
Bit 18
Bit 17
Bit 16
K
T(
IJ
)
[23..16]
R/W-X
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
K
T(
IJ
)
[15..8]
R/W-X
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
K
T(
IJ
)
[7..0]
R/W-X
Bit 31–0
K
T(
IJ
)
[31..0]: Read only
0x
n..n
Number
type
float
4
Operational description
Operational states
4.1
The basic operational states of the DPS 5000 sensor are shown in Figure 6.
Figure 6 Operational states
When power is first applied, the sensor enters the power-up state. Whilst in this
state the sensor is unresponsive to I
2
C-bus activity and user interaction with the
sensor is not possible. After the power-up checks have been completed the sensor
automatically enters the acquire state in which the sensor obtains pressure and
temperature data. User interaction with the sensor is now possible but the pressure
and temperature data will not be available until after the sensor acquisition time
and the sensor enters the stand-by state. The sensor will remain in the standby
state until either: