– 25 –
Aux Set
Aux Set - Press the Red AU
;
SET Button
Z
hen in the STOP Mode
This menu allows the user to set up various con
¿
gurations. The display has a number 0 in the left digit, and
the setting in the right digit. The heat and cool LED's are also used.
On entry, the display shows AU. Pressing MODE steps through the entries, and pr/- changes the
value. AUX saves and exits the set up.
Press "AUX SET"
First Digit
Second Digit
Press "Mode"
Press + / -
Smart Fan
- Cycle
- Cont
Temperature
Display
Sentinel
- O
ȹ
- On
Constant Fan
- O
ȹ
- On
Temperature
COOL
HEAT
0: 60°F - 85°F
0: 60°F - 65°F
Limit
1: 64°F - 85°F
1: 60°F - 70°F
Class 2
Mode
2: 66°F - 85°F
2: 60°F - 72°F
3: 68°F - 85°F
3: 60°F - 74°F
Duct Mode
4: 70°F - 85°F
4: 60°F - 76°F
5: 72°F - 85°F
5: 60°F - 78°F
All I2R Mode
(AZ65 Only)
6: 74°F - 85°F
6: 60°F - 80°F
7: 76°F - 85°F
7: 60°F - 85°F
Boost Heat
(AZ65 Only)
- O
ȹ
- On
* Factory defaults
Содержание AZ45E07DA Series
Страница 30: ...30 Service Main Board Service Main Board Continued next page...
Страница 53: ...53 Sealed System Refrigerant FloZ Cooling...
Страница 54: ...54 Sealed System Refrigerant FloZ Heating...