BEFORE YOU BEGIN

Installation  

Range Hood 

 

Instructions

 

 

Read these instructions completely and carefully.

‡

 

IMPORTANT –

 

Save these instructions for 

local inspector’s use.

‡

 

IMPORTANT –

 

Observe all governing 

codes and ordinances.

‡

Note to Installer –

 

Be sure to leave these 

instructions with the Consumer.

‡

Note to Consumer –

 

Keep these instructions 

for future reference.

‡ 6NLOOOHYHO²

 Installation of this appliance requires 

basic mechanical and electrical skills.

‡ &RPSOHWLRQWLPH²

 30 minutes–3 hours

‡

  Proper installation is the responsibility of the installer. 

‡

  Product failure due to improper installation is not 

covered under the Warranty.

NOTE: 

5HDGWKHGXFWZRUNVHFWLRQVRQO\LI\RXGRQRW

KDYHH[LVWLQJGXFWZRUN,I\RXKDYHH[LVWLQJGXFWZRUN
VNLSWRWKH´'DPDJHµVHFWLRQDQGSURFHHG

WARNING – 

725('8&(7+(5,6.2)),5($1'

723523(5/<(;+$867$,5%(685(72'8&7$,52876,'(³
'21279(17(;+$867$,5,17263$&(6:,7+,1:$//625
&(,/,1*625,172$77,&6&5$:/63$&(625*$5$*(6

The venting system must exhaust to the outside.
This hood can be vented vertically through upper cabinets or 

horizontally through an outside wall. Ductwork is not included.

([KDXVWFRQQHFWLRQ

The hood exhaust has been designed to mate with 

standard 3

1

ø

4

s

 x 10

s

 rectangular ducting or 7

s

 diameter 

round ducting.
If a 6

s

 round duct is required, a rectangular-to-round 

transition adaptor must be used*. 

Do not use less than a 

6

s

 diameter duct.

0D[LPXPGXFWOHQJWK

For satisfactory air movement, the total duct length 

of a 3

1

ø

4

s

 x 10

s

 rectangular, 6

s

 or 7

s

 diameter round 

duct 

VKRXOGQRWH[FHHGHTXLYDOHQWIHHW6HH

WKH:25.6+((7²&$/&8/$7(727$/(48,9$/(17

'8&7:25./(1*7+VHFWLRQ

NOTE: 

It is important that ducting be installed using the 

most direct route and with as few elbows as possible. 

This ensures clear venting of exhaust and helps prevent 

blockages. Also, make sure dampers swing freely and 

nothing is blocking the ducts. When applicable, install any 

makeup (replacement) air system in accordance with local 

building code requirements. Visit 

GEAppliances.com

 for 

available makeup air solutions.

(OERZVWUDQVLWLRQVZDOODQGURRIFDSVHWF

 

present additional resistance to airflow and are equivalent 

to a section of straight duct longer than their actual 

physical size. When calculating the total duct length, add 

the equivalent lengths of all transitions and adaptors plus 

the length of all straight duct sections. The charts on the 

following pages show you how to calculate total equivalent 

ductwork length using the approximate feet of equivalent 

length of some typical ducts.

'8&7:25.5(48,5(0(176

WARNING –

 

Before beginning the 

installation, switch power off at service panel and  

lock the service disconnecting means to prevent power  

from being switched on accidentally. When the service 

disconnecting means cannot be locked, securely fasten 

a prominent warning device, such as a tag, to the 

service panel.

)25<2856$)(7<

Questions?

 

Call 800.GE.CARES (800.432.2737)

 

RUYLVLWRXU:HEVLWHDW

 

GEAppliances.com

An optional Power Cord Connection Kit, model JXHC1,  

is available at extra cost from your GE supplier for 

installation using a standard 3-prong, grounded wall 

outlet. Follow the Installation Instructions packed with 

the kit to connect the power cord to the range hood.

OPTIONAL POWER CORD KIT JXHC1

6

*

 

 IMPORTANT: 

If a rectangular-to-round 

transition adaptor is used, the bottom 

corners of the damper will have to be 

cut to fit, using the tin snips, in order  

to allow free movement of the damper.  

Equivalent lengths of duct pieces  

are based on actual tests and reflect 

requirements for good venting 

performance with any hood.

Содержание AV447

Страница 1: ...47 Vent Recirculation options JV248 Vent Recirculation options JN327 Recirculation only JV338 Vent options only JV347 Vent Recirculation options JV348 Vent Recirculation options JV367 Vent Recirculation options RN328 Recirculation only AV447 Vent Recirculation options Owner s Manual and Installation Instructions Write the model and serial numbers here Model __________________________ Serial ______...

Страница 2: ...ever leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings B Always turn hood ON when cooking on high heat or when flambéing food i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flambé C Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter D Use proper pan...

Страница 3: ...température élevée Le bouillonnement occasionne des débordements fumants et graisseux qui peuvent prendre feu Chauffez à feu doux les substances huileuses avec un réglage bas ou moyen B ALLUMEZ toujours la hotte en cas de cuisson à feu élevé ou lorsque vous faites flamber des aliments par exemple crêpes Suzette cerises jubilées bœuf au poivre flambé C Nettoyez les mécanismes de ventilation fréquem...

Страница 4: ...re cool before cleaning or servicing any part of the vent hood The efficiency of your hood depends on a clean filter Frequency of cleaning depends on hood use and the type of cooking you do However the grease filter should be cleaned at least once a month To remove Pull down on the center of the front edge of the filter The filter will then slip out of the retaining tabs on the back To replace Sli...

Страница 5: ...e up until it snaps into place KDUFRDO LOWHU 5HFLUFXODWLQJ QVWDOODWLRQV 2QO Do not use steel wool pads or other abrasive cleaners They will scratch the surface Clean grease laden surfaces of the hood frequently To clean the hood surface use a hot damp cloth with a mild detergent suitable for painted surfaces About one tablespoon of ammonia may be added to the water Use a clean hot damp cloth to re...

Страница 6: ...ws as possible This ensures clear venting of exhaust and helps prevent blockages Also make sure dampers swing freely and nothing is blocking the ducts When applicable install any makeup replacement air system in accordance with local building code requirements Visit GEAppliances com for available makeup air solutions OERZV WUDQVLWLRQV ZDOO DQG URRIFDSV HWF present additional resistance to airflow ...

Страница 7: ...lbow 7s Round 28 Ft x Ft wall cap 21 ft w o with damper x Ft damper 7s Round 39 Ft x Ft roof cap 7s Round 1 Ft x Ft to 31ø4sx 10s rect transition 7s Round 5 Ft x Ft to 31ø4sx 10s rect transition 90 elbow Subtotal column 2 Ft Subtotal column 1 Ft Total ductwork Ft Installation Instructions MAXIMUM DUCT LENGTH For satisfactory air movement the total duct length of a 31ø4s x 10s rectangular 7s diamet...

Страница 8: ...de by arrangement between customer and installer 0 6 30 17 167 7 21 3 576 1 8 02817 1 63 127 6 Hood width may be greater than the width of the range or cooktop but it may not be smaller Ensure the range or cooktop is installed per manufacturer s installation instructions If you are going to vent your range hood to the outside see the Ducting Requirements section for exhaust duct preparation 66s or...

Страница 9: ...t your installation will require and that is available for your model from the below choices 1 03257 17 I WKH KRRG LV WR EH LQVWDOOHG LQ D UHFLUFXODWLQJ QRQ YHQWHG GXFWOHVV PDQQHU GR QRW NQRFN RXW DQ YHQW RSHQLQJV LQ WKH KRRG 2QO DQ HOHFWULFDO DFFHVV KROH ZLOO EH NQRFNHG RXW RI WKH KRRG JV338 JV247 JV248 JV347 JV348 JV367 AV447 JV338 JV247 JV248 JV347 JV348 JV367 AV447 JV338 JV247 JV248 JV347 JV34...

Страница 10: ...fle should be inside the hood REMOVE WIRING COVER Remove the ZLULQJ FRYHU from inside the hood Set the cover and its mounting screws aside Wiring cover 5 029 5 1 12 287 Remove either the top or the back wiring knockout as needed and install an approved VWUDLQ UHOLHI FODPS 2 3 4 6 Metal grease filter Installation Instructions VENTED is visible Strain relief clamp Back knockout Top knockout Strain r...

Страница 11: ...ion Pivot depending on installation FOR 7s ROUND VERTICAL DUCTED 6 5 167 7 216 21 Bend up the duct alignment ears in preparation for later attachment of the 7s duct 9 Installation Instructions Exhaust adaptor damper horizontal discharge position Attachment ear tabs 25 5 66 27720 1 76 ONLY Wood shims minimum thickness 3 8s I WKH FDELQHWV KDYH IURQW VLGH RU EDFN WULP PDNH 2 wood shims a minimum of 3...

Страница 12: ...ou can move the duct freely when installing the hood It may also ease installation by cutting the hole 101ø2s instead of 10s 12 0 5 2 6 Select the vent option that your installation will require and proceed to that section Hood mounting screws 4 103ø4s 24s hood 133ø4s 30s hood 163ø4s 36s hood 103ø4s 24s hood 133ø4s 30s hood 163ø4s 36s hood Cabinet front Center line Electrical access hole in cabine...

Страница 13: ...y excess length of cord and tie away with a suitable tape or tie Cabinet 73ø4s 3 prong wall outlet if using cord connection 11ø4s 13ø4s dia clearance hole for optional power supply location C L 1 5 6 Lift the hood into position and feed the house wiring through the wiring knockout 16 6 85 22 Slide the hood back against the wall Tighten the mounting screws Be sure the screw heads are in the narrow ...

Страница 14: ...htly in the center into a dome shape to allow fan clearance Reinstall and adjust as needed The fan does not work but the lights do Switch power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Check...

Страница 15: ...not available you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Service Location for service In Alaska the warranty excludes the cost of shipping or service calls to your home Some states do not allow the exclusion or limitation of incidental or consequential damages This warranty gives you specific legal rights and you may also have other rig...

Страница 16: ...t are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your warranty expires Parts and Accessories GEApplianceParts com Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discover ...

Отзывы: