Surface Lamps
The surface lamps are 120 VAC, 20 or 50 watt
(maximum) halogen bulbs (Part # WB08X10051).
To remove surface lamp assemblies:
1. Remove the Phillips-head screw from the
surface lens panel, then open the panel.
Note:
Do not touch the surface of a quartz halogen
bulb with bare
fi
ngers. The quartz surface will be
exposed to the salts and oils on the skin. This will
cause heat to concentrate in this area and lead to
premature lamp failure. If you happen to contact
the bulb with your
fi
ngers, carefully clean the quartz
surface with a gentle solvent, such as alcohol.
2. Carefully remove the defective halogen bulb(s),
then, using gloves or a cloth to hold it, carefully
replace the defective bulb(s).
Turntable Motor
The turntable motor is located on the bottom of the
microwave oven. The motor operates on 21 VAC.
To remove the turntable motor:
1. Remove 6 Phillips-head screws from the bottom
of the microwave oven cabinet.
2. Disconnect the turntable motor wiring harness.
3. Remove the single Phillips-head screw and twist
the motor slightly clockwise to release it from
the tab on the frame.
Tab
Disconnect
Turntable Coupling
To remove the turntable coupling:
Turn the turntable coupling, so the notch in the
coupling is facing the front of the microwave oven,
and lift coupling off motor shaft.
Notch
Содержание Appliances DVM1950
Страница 37: ... 37 Troubleshooting PCB ...
Страница 43: ... 43 Schematics and Wiring Diagrams Continued next page PVM2170 Schematic Diagram ...
Страница 44: ... 44 PVM2170 Wiring Diagram Continued next page ...
Страница 45: ... 45 DVM1950 JNM1951 JVM1950 PVM1970 PNM1971 Schematic Diagram Continued next page ...
Страница 46: ... 46 DVM1950 JNM1951 JVM1950 PVM1970 PNM1971 Wiring Diagram ...