BEFORE YOU BEGIN
Read these instructions completely and carefully.
Save these instructions for future use.
Installation Guide
ALB019
Risk of electrical shock. Turn power off before inspection, installation or
removal. Properly ground electrical enclosure.
Risk of fire.
Follow all NEC and local codes. Use only UL or IEC approved
wire for input/output connections. Minimum size 18 AWG.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including interference that may cause undesired operation. CAN ICES-005 (A) / NMB-005 (A)
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
Risgues de décharges électriques. Coupez l’alimentation avant d’inspecter,
installer ou déplacer le luminaire. Assurez-vous de correctement mettre à
la terre le boîtier d’alimentation électrique.
Risque d’incendie. Respectez tous les codes NEC et codes locaux.
N’utilisez que des fils approuvés par UL ou IEC pour les entrées/sorties de
connexion. Taille minimum 18 AWG.
WARNING/AVERTISSEMENT/ADVERTENCIA
Save These Instructions
Use only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer.
Prepare Electrical Wiring
Electrical Requirements
The LED driver must be supplied with 120-277 VAC or 347/480
VAC, 50/60 Hz per productlabel and connected to an individual
properlygrounded branch circuit, protected by a 15 or 20ampere
circuit breaker.
Grounding Instructions
The grounding and bonding of the overall system shall be done
in accordance with National Electric Code (NEC) Article 600 and
local codes.