“A - Disc”
Close PB Operation Remote Charge
(See Note 3 Below)
(E/O only)
Counter
Indicator
Code
No
No
No
No
X
No
No
No
Yes (N.O.)
A
No
No
Yes
No
B
No
No
Yes
Yes (N.O.)
C
No
Yes
No
No
D
No
Yes
No
Yes (N.O.)
E
No
Yes
Yes
No
F
No
Yes
Yes
Yes (N.O.)
G
Yes
No
No
No
H
Yes
No
No
Yes (N.O.)
J
Yes
No
Yes
No
K
Yes
No
Yes
Yes (N.O.)
L
No
No
No
Yes (N.C.)
R
No
No
Yes
Yes (N.C.)
S
No
Yes
No
Yes (N.C.)
T
No
Yes
Yes
Yes (N.C.)
V
Yes
No
No
Yes (N.C.)
W
Yes
No
Yes
Yes (N.C.)
Y
Note 3: ”A-Disconnect” (A-Disc) — the 36 point A-Disc is automatically
supplied whenever any of the following accessories/features are ordered:
zone selective interlock, shunt trip, auxiliary switch, bell alarm, under-
voltage, electric lockout, E/O, MVT PM.
S
elect the A-Disc if 4-wire GF is
required or if a breaker is to be "PM Ready" and none of the above
accessories/features are ordered.
"PM Ready" wiring includes inputs for
24vDC auxiliary power, communications, and 3 phase voltage.
Operation
Charge & Close
Code
manual
X
manual with remote
close
¬
Close voltage
120v-60Hz
1
240v-60Hz
3
120v-50Hz
4
240v-50Hz
6
48v -DC
A
110v-DC
B
125v-DC
C
250v-DC
D
electrical
¬
Charge / Close
48v-DC
E
120v-60Hz
F
120v-50Hz
H
120v-50
/
60
/
48v-DC N
110v-DC
P
125v-DC
Q
250v-DC
R
240v-60Hz
T
240v-50Hz
W
¬
(Requires min 4 stage auxil-
iary switch and shunt trip)
Shunt Trip-1
Code
none
X
120VAC, 60Hz
¬
1
208VAC, 60Hz
2
240VAC, 60Hz
¬
3
70VAC, 60Hz
4
120VAC, 50Hz
5
208VAC, 50Hz
6
240VAC, 50Hz
7
Code
24VDC
¬
B
48VDC
D
110 / 125VDC
¬
E
250VDC
¬
F
¬
Coil ratings available
for Shunt Trip-1 or
Shunt Trip-2. All
other ratings apply
to Shunt Trip-1 only.
Undervoltage (UV) or Electric Lockout (ELO)
(See Note 2 Below)
Code
UV
UV w/TD
ELO
none
X
X
X
120V-50/60Hz
1
4
208V-50/60Hz
3 (TAKYUVT-5)
240V-50/60Hz
2
3 (TAKYUVT-4)
5
24VDC
A
G
48VDC
B
H
110VDC
C
J
125VDC
C
E (TAKYUVT-1)
J
250VDC
D
F (TAKYUVT-2)
K
Note 2: Order Static Time Delay Unit (TAKYUVT-1,2,4,5) separately
AccessoryCode
none
X
Aux switch
4 stages
A
Aux switch
7 stages
B
Accessory Accessory Code
Bell Alarm
Push Button Cover
no no X
yes no A
yes, with lockout no
B
no
CLOSE pb
C
yes
CLOSE pb
D
yes, with lockout CLOSE pb
E
no
OPEN pb
F
yes
OPEN pb
G
yes, with lockout OPEN pb
H
no
CLOSE & OPEN pb J
yes
CLOSE & OPEN pb K
yes, with lockout CLOSE & OPEN pb L
Future use
Breaker Operation
& Control Voltages
Breaker Mounted Accessories
(Requires 4 or 7 stage aux. switch)
Accessory
Code
none
X
Shunt Trip-2
n (See “Shunt Trip-1”
(Requires 7 stage aux. switch)
codes—only those
marked
¬
are
available for 2nd
shunt trip)