TOOLS YOU MAY NEED

13

GE KIT NUMBERS

  

Power cord may include a current interrupter device. 

A test and reset button is provided on the plug case.  

The device should be tested on a periodic basis by first 

pressing the 

TEST

 button and then the

 RESET

 button. 

If the

 TEST

 button does not trip or if the 

RESET

 button 

will not stay engaged, discontinue use of the air 

conditioner and contact a qualified service technician.

Installation Instructions

    USE GE 

 

   KIT NUMBER: 

FOR: 

DESCRIPTION:

 

RAB46A, 47A 

 

Use these kits for all GE 

Standard wall case for “J” model chassis. RAG13 stamped 

  & 48A

 

models and other brands  

aluminum exterior grille included. Remove the existing case 

   

not listed 

and replace.

  RAK65A1

 

All GE Models 

Kit for window installation.

 

RAK56A100

 

GE RAB13, 14 & 15 

Fits all GE wall cases 26

W x 18

H x 24

D.

   

(ACLB & RCL Chassis)

  RAK1072

 

Hotpoint ACXB10 & 11 

Adapts an older Hotpoint wall case to a “J” model chassis.

   

(ACTB Chassis) 

Fits Hotpoint wall cases 25

3

4

W x 16

7

8

H x 18

5

8

D.

  RAK1082

 

Whirlpool Type 23W 

Adapts Whirlpool wall case to a “J” model chassis.

   

Wall Case 

Fits Whirlpool wall cases 25

7

8

W x 16

1

2

H x 23

1

8

D.

  RAK1102

 

GE RAB30 

Adapts GE wall case to a “J” model chassis.

   

(“F” models) 

Fits the RAB 30 wall case 26

W x 18

H x 24

D.

 

RAK123A64

 

Fedders Wall Case “A” 

Adapts Fedders wall case to a “J” model chassis.

   

 

Fits Fedders wall cases 27

W x 16

3

4

H x 16

3

4

D.

  RAK126

 

Westinghouse Wall Case 

Adapts Westinghouse wall case to a “J” model chassis.

   

(Type 2626D73H01) 

Fits Westinghouse wall cases 25

7

8

W x 15

7

16

H x 16

D.

 

RAB46, 47 & 48

  Use these kits for all 

Standard wall case for “J” model chassis. RAG13 stamped

   

other brands not listed. 

aluminum exterior grille included. Remove the existing case  

   

 

and replace.

  RAK690

 

RAB36, 37, 38, 46, 47 or 48  If you attach a custom architectural outdoor grille, use this kit

   

(J-Chassis) 

to ensure proper airflow. 

  RAG13

 

RAB36, 37, 38, 46, 47 or 48  Standard aluminum exterior grille (included with RAB46, 47

   

(J-Chassis) 

and 48 wall cases).

 

RAG14E

 

RAB36, 37, 38, 46, 47 or 48  Architectural louvered exterior grille.

   

(J-Chassis)

Adjustable Wrench

Level

Phillips-head  

screwdriver

Hand or Saber Saw

Drill

Pencil

Ruler or Tape Measure

Scissors or knife

Read these instructions completely and carefully.

Содержание AJCM08ACD

Страница 1: ...ling a J Model in an Existing Wall Case 14 Through the Wall Installation 15 Window Installation Optional 16 21 Troubleshooting Tips 22 Normal Operating Sounds 22 Consumer Support Consumer Support Back...

Страница 2: ...with refrigerants check with the company handling disposal about what to do SAFETY PRECAUTIONS WARNING Risk of electric shock Can cause injury or death This appliance must be properly grounded Do not...

Страница 3: ...properly grounded 2 prong wall outlet by use of a UL listed adapter available at most local hardware stores n The larger slot in the adapter must be aligned with the larger slot in the wall outlet to...

Страница 4: ...cally turn off in half an hour to 24 hours Each touch will set the time in half hours up to 10 and then in hours up to 24 To cancel the Off Timer press the OFF pad until the display time disappears SL...

Страница 5: ...umber and the indoor air will become warmer NOTE If the air conditioner is off and is then turned on while set to COOL it will take approximately 3 minutes for the compressor to start and cooling to b...

Страница 6: ...the On Timer press the ON pad until the display time disappears OFF When the air conditioner is on it can be set to automatically turn off in half an hour to 24 hours Each touch will set the time in...

Страница 7: ...circulation and filtering without cooling or heating Since fan only settings do not provide cooling or heating a temperature setting will not be displayed Remote Control Press FAN pad Press LOW or HIG...

Страница 8: ...CLOSE position Mesh end toward front Locating hole Screw hole The unit leaves the factory set at the CLOSE position The auxiliary dip switch controls are located behind the room cabinet as shown in t...

Страница 9: ...sult from improper connections Special care must be used in connecting the wires No line voltage connections should be made to any circuit Isolate all wires in building from line voltage Terminal Conn...

Страница 10: ...Hook the tabs on the front grille even with the tabs on the case and snap into place Replace the screws and filter Front Grille Outdoor Coils The coils on the outdoor side of the air conditioner shou...

Страница 11: ...onditioner is to clean the filter at least every 30 days A clogged filter reduces cooling heating and air flow Keeping the air filter clean will n Decrease cost of operation n Save energy n Prevent cl...

Страница 12: ...pliances com Installation Air Conditioner Instructions 12 ELECTRICAL REQUIREMENTS cont Some models require 230 208 volt a c protected with a time delay fuse or circuit breaker These models should be i...

Страница 13: ...apts Whirlpool wall case to a J model chassis Wall Case Fits Whirlpool wall cases 257 8 W x 161 2 H x 231 8 D RAK1102 GE RAB30 Adapts GE wall case to a J model chassis F models Fits the RAB 30 wall ca...

Страница 14: ...STALLING A J MODEL IN AN EXISTING WALL CASE Read these instructions completely and carefully Remove shipping pads if present CAREFULLY SLIDE AIR CONDITIONER BACK INTO CASE Make sure that the tubing on...

Страница 15: ...the opening should be structural wall members Lintel Use a lintel in brick veneer and brick and block types of wall to support the bricks or blocks above the opening Do not allow the wall case to be u...

Страница 16: ...d right hand Case side gasket 2 Vinyl window gasket Bottom window gasket Case top gasket Foam top window gasket B Right side A Left side holes are on the left holes are on the right WINDOW REQUIREMENT...

Страница 17: ...pressure on the grille until it fits flush with the bottom of the case 17 STORM WINDOW REQUIREMENTS A storm window frame will not allow the air conditioner to tilt towards the outside and will keep it...

Страница 18: ...require a longer adjusting bolt than the standard hex head bolt provided On wood sills use the large washer between the bolt head and the sill This prevents the bolt from digging into the wood PREPAR...

Страница 19: ...and attach it to the angle Push a pencil point through the gaskets to locate the holes in the angles Install the panels in the window Place the spring clips 3 from the top and the bottom Squeeze and...

Страница 20: ...With the window closed mark where the window sash meets the case Peel off the backing from the case top gasket Hold on to the case open the window and place the gasket along the mark on the case Place...

Страница 21: ...e front grille An opening for the power cord is on the bottom of the front grille Fill holes and cracks with caulking provided by the installer INSTALL WINDOW GASKET AND LOCKING BRACKET Cut the foam t...

Страница 22: ...of the air conditioner and contact a qualified service technician Air conditioner does Airflow is restricted Make sure there are no curtains blinds or furniture blocking not cool or heat some the fro...

Страница 23: ...Replacement of house fuses or resetting of circuit breakers n Failure due to corrosion on models not corrosion protected n Damage to the product caused by improper power supply voltage accident fire f...

Страница 24: ...while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your warranty expires...

Отзывы: