background image

Operating Instructions

Safety Instructions

Customer Service

Troubleshooting T

ips

5

Removing Collected Water

There are 2 ways to remove collected water:

Use the bucket.

When the bucket is full, 

the 

WATER FULL

indicator blinks and the

unit beeps 3 times and stops. Wait  a few
minutes before removing the bucket to
allow the water to stop dripping. 

To remove:

Tilt the bucket forward then 

lift carefully. After emptying, clean and
replace it.

Use a hose.

Water can be automatically 

emptied into a drain by attaching a length 
of thin-wall rubber or plastic tubing with an
inside diameter of 1/2 inch. Use a screwdriver
to remove the knockout at the back. Attach
the tubing to the connector through the hole.
The tubing should lead to the drain with no
sharp bends.

Cleaning the Grille and Case

Turn the dehumidifier off and remove the plug
from the wall outlet before cleaning.

Use water and a mild detergent to clean the inlet
and outlet grilles. Do not use bleach or abrasives.

Air filter

NOTE: 

The charcoal filter has been packed separately, in the

bucket, in the front of the unit. Remove the wrap and insert it
in the filter frame with the darker surface up.

The air filter is on the back of the dehumidifier. 
It should be checked and cleaned at least every 
2 to 3 weeks or more often if necessary.

To remove:

Turn the dehumidifier off and lift out

the filter on the back of the unit.

Vacuum the nylon filter or wash with water. 
Make sure it is dry before replacing it.

The charcoal filter should be replaced every 
3 to 6 months or when the inside surface has
changed from white to a dark color.

Call 800-626-2002 to order a replacement.

Nylon filter

Charcoal filter

Bucket

Содержание AHG20

Страница 1: ...ut from the receptacle Repair or replace immediately all electric service cords that have become frayed or otherwise damaged Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end Turn the humidity control to OFF and unplug your dehumidifier before making any repairs or cleaning NOTE We strongly recommend that any servicing be performed by a ...

Страница 2: ...r until a proper ground has been established Attaching the adapter ground terminal to a wall outlet cover screw does not ground the appliance unless the cover screw is metal and not insulated and the wall outlet is grounded through the house wiring You should have the circuit checked by a qualified electrician to make sure the outlet is properly grounded USE OF ADAPTER PLUGS READ AND FOLLOW THIS S...

Страница 3: ... you will find many helpful hints on how to use and maintain your dehumidifier properly Just a little preventive care on your part can save you a great deal of time and money over the life of your dehumidifier READ THIS MANUAL IF YOU NEED SERVICE You ll find many answers to common problems in the Before You Call For Service section If you review our chart of Troubleshooting Tips first you may not ...

Страница 4: ...l bucket is full or humidity is below 35 CLEAN AIR FAN ONLY The compressor is off but the fan runs Controls Operating Instructions Safety Instructions Customer Service Troubleshooting Tips DEHUMIDIFY WATER FULL 70 60 AUTOMATIC ON OFF OFF CLEAN AIR FAN ONLY CONTINUOUS RUN 60 50 AUTOMATIC ON OFF CURRENT HUMIDITY FUNCTION Choosing a Location The dehumidifier must be operated in an enclosed area to be...

Страница 5: ...drain with no sharp bends Cleaning the Grille and Case Turn the dehumidifier off and remove the plug from the wall outlet before cleaning Use water and a mild detergent to clean the inlet and outlet grilles Do not use bleach or abrasives Air filter NOTE The charcoal filter has been packed separately in the bucket in the front of the unit Remove the wrap and insert it in the filter frame with the d...

Страница 6: ...linds or furniture blocking the front or back of the dehumidifier Clean the filter The control may not Choose a lower humidity range or CONTINUOUS RUN be set correctly Doors and windows may not Check that all doors windows and other openings are be closed tightly securely closed Clothes dryer may be Install the dehumidifier away from the dryer The dryer blowing moisture laden should be vented to t...

Страница 7: ...ilities Failure of the product resulting from modifications to the product or due to unreasonable use including failure to provide reasonable and necessary maintenance In commercial locations labor necessary to move the unit to a location where it is accessible for service by an individual technician Replacement of house fuses or resetting of circuit breakers Failure due to corrosion on models not...

Страница 8: ...expires Parts and Accessories 800 626 2002 Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discover cards are accepted Instructions contained in this manual cover procedures to be performed by any user Other servicing generally should be referred to qualified service personnel Caution must be exercised since impro...

Отзывы: