Lights next to the touch pads on the air conditioner
control panel indicate the selected settings. 

Consumer Support

Tr

oubleshooting T

ips

Operating Instructions

Safety Instructions

Installation Instructions

TI

Use the 

Cool

mode with 

HIGH (F3), MED (F2)  

or

LOW (F1)

fan for cooling. Use the 

INCREASE 

▲ 

/

DECREASE 

▼ 

pads to set the desired temperature

between 60°F and 86°F in 1°F increments.

An electronic thermostat is used to maintain the
room temperature. The compressor will cycle on and
off to keep the room at the set level of comfort. Set
the thermostat at a lower number and the indoor air
will become cooler. Set the thermostat at a higher
number and the indoor air will become warmer.

NOTE:

If the air conditioner is off and is then turned on

while set to a 

Cool

setting or if turned from a fan setting

to a 

Cool

setting, it will take approximately 3 minutes for

the compressor to start and cooling to begin.

Cooling Descriptions

For Normal Cooling—

Select the 

Cool

mode and 

HIGH (F3)

or 

MED (F2) 

fan with a middle set

temperature.

For Maximum Cooling—

Select the 

Cool

mode 

and 

HIGH (F3)

fan with a lower set temperature.

For Quieter & Nighttime Cooling—

Select the 

Cool

mode and 

LOW (F1)

fan with a middle set

temperature.

NOTE:

If you switch from a 

Cool

setting to 

OFF

or to 

a fan setting, wait at least 3 minutes before switching
back to a 

Cool

setting.

Cool Mode

Use the fan at 

HIGH (F3), MED (F2) 

or

LOW (F1)

to

provide air circulation and filtering without cooling.
Since fan only settings do not provide cooling, 
a temperature setting will not be displayed.

Fan Speed Mode

The vent control is located beside the control
panel.

When set at 

CLOSE

, only the air inside the room 

will be circulated and conditioned. When set at

OPEN

, some inside air is exhausted outside.

Vent Control

To open the vent, pull the lever toward you.
To close it, push it in.

The side-to-side air direction is adjusted by moving
the lever to the left or right.

Air Direction—Side-to-Side

Fingertip pressure on the horizontal louvers
adjusts the air direction up or down.

Air Direction—Up and Down

Содержание AGW12AK

Страница 1: ...stallation Optional 13 Window Installation 8 12 Troubleshooting Tips 14 Normal Operating Sounds 15 Consumer Support Consumer Support 18 Warranty 17 3828A21031L 49 7565 11 06 JR Owner s Manual and Inst...

Страница 2: ...product with refrigerants check with the company handling disposal about what to do SAFETY PRECAUTIONS Do not under any circumstances cut or remove the third ground prong from the power cord For perso...

Страница 3: ...nst the use of an extension cord However if you must use an extension cord it is absolutely necessary that it be a UL listed 14 gauge 3 wire grounding type appliance extension cord having a grounding...

Страница 4: ...When the air conditioner is off it can be set to automatically come on in 1 to 12 hours at its previous setting Each touch will set the timer in hours OFF When the air conditioner is on it can be set...

Страница 5: ...iptions For Normal Cooling Select the Cool mode and HIGH F3 or MED F2 fan with a middle set temperature For Maximum Cooling Select the Cool mode and HIGH F3 fan with a lower set temperature For Quiete...

Страница 6: ...d regularly If they are clogged with dirt or soot they may be professionally cleaned Outdoor Coils The air filter behind the front grille should be checked and cleaned at least every 30 days or more o...

Страница 7: ...a 115 120 volt a c 60 Hz grounded outlet protected with a 15 amp time delay fuse or circuit breaker The 3 prong grounding plug minimizes the possibility of electric shock hazard If the wall outlet you...

Страница 8: ...t Right accordion panel Foam top window gasket Window sash seal Left accordion panel Type B 3 Type C 5 Bolt 2 Nut 2 Frame guide 2 Top mounting rail seal strip Top mounting rail PARTS INCLUDED Appearan...

Страница 9: ...TORM WINDOW REQUIREMENTS A storm window frame will not allow the air conditioner to tilt toward the outside and will keep it from draining properly To adjust for this attach a piece of wood to the sto...

Страница 10: ...ing and attach the seal to the underside of the window sash A 4 PREPARE THE WINDOW AND THE CASE CONT Carefully insert the plastic frame guides into the bottom of the case on each side Remove the backi...

Страница 11: ...n the sill Attach the sill supports to the case track hole in relation to the selected position using 2 type A screws in each support E D C B A 5 Window Installation Instructions Bolt Nut Sill support...

Страница 12: ...e Caulk or weather strip any gaps or openings to the outside to seal the installation D C B Window Installation Instructions INSTALL THE WINDOW LOCKING BRACKET AND THE FOAM TOP WINDOW GASKET Attach a...

Страница 13: ...ertain that a wall receptacle is available close to the hole location or make arrangements to install a receptacle Place the case in the wall opening and place wood support strips between the case bot...

Страница 14: ...When the air conditioner is first turned on you need to allow time for the room to cool down Cold air is escaping Check for open furnace floor registers and cold air returns Set the air conditioner s...

Страница 15: ...fficiency You may hear the thermostat click when the compressor cycles on and off Water will collect in the base pan during high humidity or on rainy days The water may overflow and drip from the outd...

Страница 16: ...16 Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Notes...

Страница 17: ...equential damage caused by possible defects with this air conditioner What Is Not Covered This warranty is extended to the original purchaser and any succeeding owner for products purchased for home u...

Страница 18: ...bilities check out our Website today For the hearing impaired please call 800 TDD GEAC 800 833 4322 Parts and Accessories ge com Individuals qualified to service their own appliances can have parts or...

Страница 19: ...ose para instalar el acondicionador de aire 7 Solucionar problemas 15 Sonidos normales de operaci n 16 Apoyo al consumidor Apoyo al consumidor 18 Garant a 17 3828A21031L 49 7565 11 06 JR Manual del pr...

Страница 20: ...de alg n producto que contenga refrigerantes p ngase en contacto con la compa a que se encarga de recoger su basura para que le indiquen qu hacer PRECAUCIONES DE SEGURIDAD Bajo ninguna circunstancia c...

Страница 21: ...co de extensi n es absolutamente necesario que el mismo est listado bajo UL sea calibre 14 del tipo de 3 tomas con conexi n a tierra para electrodom sticos y el ndice el ctrico debe ser de 15 amperios...

Страница 22: ...el acondicionador de aire est encendido puede ajustarse para que se apague autom ticamente dentro de 1 a 12 horas Cada toque ajustar el tiempo en horas Para cancelar el sincronizador presione la tecla...

Страница 23: ...ura de ajuste menor Para enfriamiento silencioso y enfriamiento nocturno Seleccione el modo de ventilador Cool y LOW F1 BAJO con una temperatura de ajuste media NOTA Si cambia de un ajuste Cool Fr o a...

Страница 24: ...tro de aire detr s de la rejilla frontal debe inspeccionarse y limpiarse por lo menos cada 30 d as o m s a menudo si fuese necesario Para retirarlo Abra la rejilla de entrada hacia abajo tirando de la...

Страница 25: ...leta y cuidadosamente IMPORTANTE Guarde estas instrucciones para uso del inspector local IMPORTANTE Observe todos los c digos y rdenes de ley Nota al instalador Aseg rese de dejar estas instrucciones...

Страница 26: ...l de acorde n izquierdo Tipo B 3 Tipo C 5 Tornillo 2 Tuerca 2 Gu a del marco 2 Cinta de sellado del riel de montaje superior Top mounting rail PARTES INCLUIDAS apariencia puede variar Instrucciones de...

Страница 27: ...TORMENTAS Un marco de ventana de tormentas no permitir que el acondicionador de aire se incline hacia el exterior y evitar que drene apropiadamente Para solucionar este problema adhiera un pedazo de...

Страница 28: ...la banda de sellado del riel de montura superior y nala al fondo del riel de montaje superior Instale el riel de montaje superior con 3 tornillos tipo A en el interior de la caja Inserte los marcos pa...

Страница 29: ...alejado en el umbral Una los soportes del umbral al agujero de trayectoria de la caja en relaci n con la posici n seleccionada usando dos tornillos tipo A en cada soporte E D C B A 5 Tornillo Tuerca S...

Страница 30: ...n localizada al lado del panel de control de la unidad como se muestra Una la parrilla del frente a la caja insertando las orejillas en la parrilla en las ranuras en el frente de la caja Empuje la pa...

Страница 31: ...buja Es necesaria una escuadra de lintel para dar soporte a los ladrillos o bloques que se encuentran por encima de la abertura Se necesitan tapajuntas que deben extenderse a lo largo de la abertura p...

Страница 32: ...ci n Coloque el acondicionador de aire hacia el interior de la caja Para instrucciones espec ficas refi rase a las Instrucciones para la instalaci n en una ventana 2 ngulo del lintel L nea del yeso Mo...

Страница 33: ...rese de que los registros de la calefacci n no est n abiertos y se encuentran retornando el aire fr o Coloque la ventanilla del acondicionador de aire en la posici n cerrada Las bobinas de enfriamien...

Страница 34: ...ora la eficiencia Quiz s escuche que el termostato hace clic cuando el compresor hace ciclo entre encendido y apagado El agua se acumula en la bandeja durante d as lluviosos o con mucha humedad El agu...

Страница 35: ...mayor Da os incidentales o consecuenciales causados por defectos posibles con este acondicionador de aire Lo que no est cubierto Esta garant a se extiende al comprador original y cualquier comprador...

Страница 36: ...on dificultades auditivas favor de llamar al 800 TDD GEAC 800 833 4322 Piezas y accesorios ge com Aquellos individuos con la calificaci n necesaria para reparar sus propios electrodom sticos pueden pe...

Отзывы: