Cabinetry

Built-In Speedcook Ovens

Prepare the
Opening

Order a 30" wide single oven cabinet or cut
the opening in a wall to dimensions shown.

The rough opening must be:
• Depth - 19" Min.
• Width - 28-1/2" Min.
• Height - 21" Min.
• 36-3/4" from the floor to the cutout is

required.

• These ovens require 3/4" overlap on each

side, top and bottom of the cutout.

• Oven overlaps will conceal cut edges on all

sides of the opening.

When installed over a single oven or a
warming drawer, allow at least 2" between the
two openings. This separation will provide
clearance for bottom overlap of the
Speedcook Oven and top overlap of the
single oven or warming drawer.

• Construct a solid oven floor of 3/8" min.

thick plywood supported by 2 x 4 or 1 x 2
runners on all sides.

• The support must be level and rigidly

mounted, flush with the bottom edge of the
cutout.

 For personal safety,

the mounting surface must be capable of
supporting the cabinet load, in addition
to the added weight of this approximate 100
pound product, plus, additional oven loads
of up to 50 pounds or a total weight of 150
pounds.

CAUTION

Single Speedcook Installation

Speedcook Oven Installed above a
GE/Monogram Built-In Wall Oven

*If you are replacing a GE/Monogram electric

double oven with the combined installation
of a Speedcook and single wall oven, use the
dimensions shown. The middle rail
separating the two openings may need to be
larger than the 2" min. shown.

•  Always maintain 36-3/4" min. distance from

the floor to the Speedcook oven cutout in
any installation combination.

Speedcook Oven Installed above a
GE/Monogram Warming Drawer

Note:

 

Additional clearance between the cutouts may be required.

Check to be sure the oven supports above the Warming Drawer
location does not obstruct the required interior 23-1/2" depth and
9-1/4" height. See installation instructions for details.

When installing the Speedcook oven over
a GE/Monogram electric warming drawer,
follow the product installation instructions.
• An anti-tip block must be installed at the rear

of the warming drawer opening. Again, see
installation instructions for complete details.

*45-1/4"

30"

24"

Min.

Construct Solid 
Bottom Min. 3/8" 
Plywood
Supported by
2 x 4 or 1 x 2
Runners, all
Four Sides

2" Min.

Per Oven
Requirement

28-1/2"

21"

36-3/4" Min.

Required

 30"

19"

Min

Construct Solid
Bottom Min. 3/8" 
Plywood
Supported by
2 x 4 or 1 x 2
Runners, all
Four Sides

28-1/2"

21"

36-3/4" Min.

30"

24"

Min.

Construct Solid 
Bottom Min. 3/8" 
Plywood
Supported by
2 x 4 or 1 x 2
Runners, all
Four Sides

2" Min.

Install 2 x 4 
or 2 x 2
Runners or
Solid Bottom,
Must Support
100 lbs.

28-1/2"

21"

9-1/4"

Содержание Advantium SCB2000

Страница 1: ...AdvantiumTM Built In Speedcook Ovens Installation Instructions SCB2000 SCB2001 ZSC2000 ZSC2001...

Страница 2: ...444 1845 For Monogram service in Canada call 1 888 880 3030 For Monogram Parts and Accessories call 1 800 626 2002 Use this appliance only for its intended purpose CAUTION This oven should be install...

Страница 3: ...For personal safety this oven cannot be installed in a cabinet arrangement such as an island or peninsula Cabinets installed adjacent to wall ovens must have an adhesion spec of at least 194 F tempera...

Страница 4: ...l Oven If you are replacing a GE Monogram electric double oven with the combined installation of a Speedcook and single wall oven use the dimensions shown The middle rail separating the two openings m...

Страница 5: ...e must remain grounded to the oven If cold water pipe is interrupted by plastic non metallic gaskets union connections or other insulating materials DO NOT use for grounding DO NOT ground to a gas pip...

Страница 6: ...ot get pinched between the back of the oven and the cabinet wall Slide oven into the cabinet opening Drill 3 32 pilot holes into the cabinet frame through the 4 mounting holes in the oven front frame...

Страница 7: ...ven red lead to branch circuit red lead Connect oven black lead to branch circuit black lead Connect oven green ground lead and white lead to branch circuit neutral white or gray grounding terminal or...

Страница 8: ...Pub No 49 40103 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE DWG NO 164D3370P101 N D 530 2 00 Printed in Korea LG P N 3828W5U0080...

Отзывы: