Table 5: 8RP Board address settings  

 

SW 1- 

SW 2- 

Board 

type 

5 6 7 8 1 2 3 4 5 6 7 8 

Board 

[1] 

N/A N/A OFF ON ON OFF ON OFF ON OFF ON OFF 

Board 

[2] N/A N/A OFF ON  ON  ON  OFF OFF OFF ON  OFF ON 

[1]  The first 8 readers out of 16. 
[2]  The second 8 readers out of 16. 

 

Wiring  

It is recommended that 20 AWG shielded cable be used 
for wiring reader DOs and DIs. Use plenum-rated cable 
for applications where cable is to be run above the false 
(suspended) ceiling in the air circulation space. 

Allow some slack wire for servicing the cables and for 
plugging the cable into an adjacent slot for 
troubleshooting. 

Wiring the readers 

1.  Install the reader in accordance with the 

manufacturer’s instructions. 

2.  Run the appropriate cable from the reader to the 

controller. Bring each reader cable through the 
appropriate knockout hole in the controller cabinet. 

3.  Remove eight inches of insulating material from the 

cable. Unwrap shielding and tie all shields together. 
Connect the communications cable shield to the 
ground nut adjacent to the cable entrance knockout 
of the cabinet enclosure. For more details, see Figure 
2. 

Caution: 

The 8RP Board has built-in pull-up resistors. Do 

not install the external pull-up resistors supplied with the 
GE Proximity Readers. 

4.  Depending on your configuration, attach the 

appropriate wires to the appropriate screw terminal 
on the 8RP Board as shown in Figure 3, Figure 4, and 
Figure 5. Refer to Table 6 for connector pinouts. 

Pairing of cables is very important. Refer to the 
examples in Table 6. 

5.  To ensure proper function when using two 8RP 

Boards in the M5 and M3000 controllers, the second 
8RP Board should be wired directly to the Power 
Communication Board, as shown in Figure 4 

6.  Label each cable end with the controller address 

number and the device or reader number.  

Figure 2: Typical installation using shielded cable/drain wire inside 
and outside of the enclosure 

 

Table 6: J2/J3/J4/J5 reader connector pinouts and typical pairing 

Reader port 

Pin 

Signal name 

Typical wire color 

1/3/5/7 1 

+12 

VDC 

Red 

 2 

Ground 

Black 

 3 

Reader 

data 

Green 

 

Door DO (reader LED) 

White 

2/4/6/8 5 

+12 

VDC 

Red 

 6 

Ground 

Black 

 7 

Reader 

data 

Green 

 

Door DO (reader LED) 

White 

Содержание 8RP Board

Страница 1: ...ded use only GE supervised F 2F keypad readers or Wiegand Interface Units WIU 2 WIU 4 Each reader reader based DI input point and reader based exit DI on the 8RP Board is addressed differently depending on the host system you are using The 8RP Board provides one digital output reader LED per reader port 12 VDC 100 mA maximum per output point Verify contents Caution While the 8RP has been designed ...

Страница 2: ...r 11 and 12 Reader 13 and 14 Reader 15 and 16 Picture Perfect board number 5 6 7 8 Readers 0 and 1 0 and 1 0 and 1 0 and 1 Door DIs 0 and 1 0 and 1 0 and 1 0 and 1 Exit DIs 8 and 9 8 and 9 8 and 9 8 and 9 Door DOs 0 and 1 0 and 1 0 and 1 0 and 1 1 The second 8 readers out of 16 See Table 5 for board type settings Facility Commander Wnx and Secure Perfect The Facility Commander Wnx and Secure Perfe...

Страница 3: ...ions cable shield to the ground nut adjacent to the cable entrance knockout of the cabinet enclosure For more details see Figure 2 Caution The 8RP Board has built in pull up resistors Do not install the external pull up resistors supplied with the GE Proximity Readers 4 Depending on your configuration attach the appropriate wires to the appropriate screw terminal on the 8RP Board as shown in Figur...

Страница 4: ...all a protection diode across the relay and the door strike Use 1N4002 1N4003 1N4004 or equivalent diodes for DC door strikes and Metal Oxide Varistors MOV for AC door strikes See Figure 3 4 Protection diode or MOV and blocking diode are required at all electronic door locks 5 Install a blocking diode on the door DO Reader LED line between the reader and the door strike relay Use 1N5817 diode whic...

Страница 5: ...P N 460235001J ISS 21MAR08 5 of 6 Figure 4 Powering two 8RP Boards Figure 5 Wiring 8RP to WIU 4 Wiegand readers ...

Страница 6: ... AWG shielded pairs Operating environment Temperature Humidity 35 to 122 F 2 to 50 C 5 to 95 RH noncondensing at 90 F 32 C Contacting customer support You can reach customer support by phone from 8 a m to 7 p m EST Monday through Friday GE Security United States 1 888 GE SECURITY 1 888 437 3287 Asia 852 2907 8108 Australia 61 3 9259 4700 Europe 48 58 326 22 40 Latin America 305 593 4301 ...

Отзывы: