Wiring the door strike 

One reader LED (door DO) is dedicated to each reader. 
The reader LED (door DO) is used for the reader LED or for 
an external door strike relay. 

1.  Install the door strike as required. 

2.  Wire the door strike to the external door strike relay. 

The door strike relay is connected to +12 VDC (pin 1 
and/or pin 5) and door DO (pin 4 and/or pin 8). 

3.  Install a protection diode across the relay and the 

door strike. Use 1N4002, 1N4003, 1N4004 or 
equivalent diodes for DC door strikes and Metal Oxide 
Varistors (MOV) for AC door strikes. See Figure 3. 

4.  Protection diode or MOV and blocking diode are 

required at all electronic door locks. 

5.  Install a blocking diode on the door DO (Reader LED) 

line between the reader and the door strike relay. 
Use 1N5817 diode, which is included with the reader. 
The diode must be installed on the secure side of the 
door in order to be UL compliant. See Figure 3. 

Figure 3: Wiring 8RP to F/2F or supervised F/2F readers (2 state) 

 

Содержание 8RP Board

Страница 1: ...ded use only GE supervised F 2F keypad readers or Wiegand Interface Units WIU 2 WIU 4 Each reader reader based DI input point and reader based exit DI on the 8RP Board is addressed differently depending on the host system you are using The 8RP Board provides one digital output reader LED per reader port 12 VDC 100 mA maximum per output point Verify contents Caution While the 8RP has been designed ...

Страница 2: ...r 11 and 12 Reader 13 and 14 Reader 15 and 16 Picture Perfect board number 5 6 7 8 Readers 0 and 1 0 and 1 0 and 1 0 and 1 Door DIs 0 and 1 0 and 1 0 and 1 0 and 1 Exit DIs 8 and 9 8 and 9 8 and 9 8 and 9 Door DOs 0 and 1 0 and 1 0 and 1 0 and 1 1 The second 8 readers out of 16 See Table 5 for board type settings Facility Commander Wnx and Secure Perfect The Facility Commander Wnx and Secure Perfe...

Страница 3: ...ions cable shield to the ground nut adjacent to the cable entrance knockout of the cabinet enclosure For more details see Figure 2 Caution The 8RP Board has built in pull up resistors Do not install the external pull up resistors supplied with the GE Proximity Readers 4 Depending on your configuration attach the appropriate wires to the appropriate screw terminal on the 8RP Board as shown in Figur...

Страница 4: ...all a protection diode across the relay and the door strike Use 1N4002 1N4003 1N4004 or equivalent diodes for DC door strikes and Metal Oxide Varistors MOV for AC door strikes See Figure 3 4 Protection diode or MOV and blocking diode are required at all electronic door locks 5 Install a blocking diode on the door DO Reader LED line between the reader and the door strike relay Use 1N5817 diode whic...

Страница 5: ...P N 460235001J ISS 21MAR08 5 of 6 Figure 4 Powering two 8RP Boards Figure 5 Wiring 8RP to WIU 4 Wiegand readers ...

Страница 6: ... AWG shielded pairs Operating environment Temperature Humidity 35 to 122 F 2 to 50 C 5 to 95 RH noncondensing at 90 F 32 C Contacting customer support You can reach customer support by phone from 8 a m to 7 p m EST Monday through Friday GE Security United States 1 888 GE SECURITY 1 888 437 3287 Asia 852 2907 8108 Australia 61 3 9259 4700 Europe 48 58 326 22 40 Latin America 305 593 4301 ...

Отзывы: