38
INSTALLATION INSTRUCTIONS
(continued)
STEP 9
LEVELING THE RANGE
The range must be level. Leveling feet are located
at each corner of the base of the range. Remove
the storage drawer or kick panel (depending on
your model) and using channel locks, rotate the
leveling feet in and out as required to level the
range. (For instructions on how to remove and
replace the storage drawer or the kick panel, see
the Cleaning Under the Range section in Care
and Cleaning.) On some models, there are plastic
covers which may be removed for easy
adjustment (just squeeze and pull).
One of the rear leveling feet will engage the
ANTI-TIP bracket (allow for some side to side
adjustment). Allow a minimum clearance of 1/8-
inch between the range and the leveling foot that
is to be installed into the ANTI-TIP bracket.
Check the range for proper installation into the
ANTI-TIP bracket (after the range has been
properly installed) by removing the kick panel or
storage drawer and inspecting the rear leveling
leg. Make sure it fits securely into the slot.
STEP 10
FINAL CHECK
Be sure all switches are in the OFF position
before leaving the range.
STEP 8
ANTI-TIP BRACKET INSTALLATION
AN ANTI-TIP bracket is supplied with instructions
for installation in a variety of locations. The
instructions include a template, a parts list and a
list of tools necessary to complete the installation.
Read the IMPORTANT SAFETY INSTRUCTIONS
and the instructions that fit your situation before
beginning installation.
WARNING
1. Range must be secured by ANTI-TIP bracket
supplied.
2. See instructions to install (supplied with
bracket).
3. Unless properly installed, range could be
tipped by stepping or sitting on door. Injury
might result from spilled hot liquids or from
range itself.
Typical Installation of Anti-Tip Bracket
Attachment to Wall
Bracket
Wall Plate
Screw Must Enter
Wood or Metal