background image

 

Specifications and Ordering Information 

Part Number 165361-01 

Rev. D (06/07) 

 

Page 3 of 4 

Magnetic Field 

EN 61000-4-8, Criteria A 

Power Supply 
Dip 

EN 61000-4-11, Criteria B 

Low Voltage 
Directives 

EN 61010-1 

Safety Requirements 

Hazardous Approvals 

CSA/NRTL/C: 

Class 1, Division 2, Groups A, B, C, 
D T4 @ Ta = 65°C 

Physical 

Main Module 

Dimensions 
(Height x Width 
x Depth) 

241.3 mm x 24.4 mm x 241.8 mm 
(9.50 in x 0.96 in x 9.52 in) 

Weight 

0.79 kg (1.75 lbs.). 

I/O Modules 

Dimensions 
(Height x Width 
x Depth) 

241.3 mm x 24.4 mm x 99.1 mm 
(9.50 in x 0.96 in x 3.90 in) 

Weight 

0.39 kg (0.85 lb.). 

Rack Space 
Requirements 

Main Module 

1 full-height front slot 

I/O Modules 

1 full-height rear slot 

Ordering Information 

Ordering Considerations 

Version 3.70 (release pending)  or higher of 3500 Rack 
Configuration Software is required. 

The 3500/91 EGD requires a 3500/22M TDI to communicate 
with monitor modules. 

Only 1 EGD per rack is allowed. 

Version 1.20 (release pending) or higher of TDI (3500/22M) 
firmware is required. 

For consumed exchange support, version 2.21 (release 
pending) or higher of 4-Channel firmware is required. 

List of Options and Part Numbers 

The 3500/91 EGD Communication Gateway 

3500/91-AXX-BXX-CXX 

A:

  Main Module Type 

0 1

 

EGD Communication Gateway Module 

B:

  I/O Module Type

  

0 1

 

Ethernet 10BASE-T/100BASE-TX I/O Module 

0 2

 

Ethernet 100BASE-FX I/O Module 

C:

  Agency Approval Option 

0 0

 

None 

0 1

 

CSA/NRTL/C 

Spares 

TBD 

3500/91 Manual 

161204-01 

3500/91 EGD Gateway Module 

161216-01 

Ethernet 10BASE-T/100BASE-TX 
I/O Module 

161216-02 

Ethernet 100BASE-FX I/O Module 

Network Accessories 

Refer to our Network Accessories datasheet 164466-01 

 

Содержание 3500/91 EGD

Страница 1: ...ored values and status This Ethernet network path provides information with response times suitable for controller applications Using the 3500 91 EGD Gateway provides for integration with EGD protocol compatible controllers e g GE Mark VIe controllers etc Supported protocols include EGD version 2 01 Ethernet UDP IP The Ethernet standards supported by the 3500 91 I O modules are IEEE802 3 for 10BAS...

Страница 2: ... 3 CSMA CD Communication Link Ethernet 10 Mbps and 100 Mbps and conforms to IEEE 802 3 and IEEE802 3u Protocol Ethernet UDP IP frame Connection RJ 45 jack for the Ethernet 10BASE T 100BASE TX I O Module MT RJ jack for the Ethernet 100BASE FX I O Module Environmental Limits Operating Temperature 30 C to 65 C 22 F to 150 F Storage Temperature 40 C to 85 C 40 F to 185 F Humidity 95 noncondensing CE M...

Страница 3: ...tions Version 3 70 release pending or higher of 3500 Rack Configuration Software is required The 3500 91 EGD requires a 3500 22M TDI to communicate with monitor modules Only 1 EGD per rack is allowed Version 1 20 release pending or higher of TDI 3500 22M firmware is required For consumed exchange support version 2 21 release pending or higher of 4 Channel firmware is required List of Options and P...

Страница 4: ...et 10BASE T 100BASE TX I O Module 4 Ethernet 100BASE FX I O Module Bently Nevada and Mark are trademarks of General Electric Company Copyright 2003 Bently Nevada LLC 1631 Bently Parkway South Minden Nevada USA 89423 Phone 775 782 3611 Fax 775 215 2873 www ge energy com bently All rights reserved Cl as s 1 La ser Pr od uc t Co mp lie s wit h 21 CF R 10 40 10 an d 10 40 11 ...

Отзывы: