![GE Security NetworX Series Скачать руководство пользователя страница 35](http://html.mh-extra.com/html/ge-security/networx-series/networx-series_installation-and-startup_572050035.webp)
NX-8V2 Control
35
LOC
PG
DESCRIPTION
DEFAULT
PROGRAM DATA
L
37
19
SIREN AND SYSTEM SUPERVISION
Segment 1 (Circle Numbers To Program)
1 =
Siren sounds for telephone line cut while armed.
2 =
Siren sounds for telephone line cut while disarmed.
3 =
Siren blast at arming.
4 =
Siren blast at exit delay expiration.
5 =
Siren blast at closing kissoff.
6 =
Siren sounds during a cross-zone verification time.
7 =
Siren sounds for a tamper.
8 =
Siren blast one time for keyswitch arming, two times for disarming.
(
Note
: Must be disabled for SIA CP-01 installations.)
Segment 2 (Circle Numbers To Program)
1 =
Convert siren driver to voltage out.
2 =
Siren sounds for expander trouble (required for U.L.).
3 =
Immediate Restore by zone.
4 =
Dynamic battery test performed upon arming.
5 =
Battery missing test performed every 12 seconds.
6 =
Manual bell test performed during [
r
]-[4]-[4] test function.
7 =
Manual communicator test performed during [
r
]-[
4
]-[
4
] test function.
8 =
Box tamper enabled.
Segment
3
(Circle numbers to program)
1 =
Box Tamper report enabled.
2 =
AC Fail report enabled.
3 =
Low Battery report enabled.
4 =
Auxiliary power over current report enabled.
5 =
Siren supervision report enabled.
6 =
Telephone Line Cut report enabled.
7 =
Ground Fault Detection report enabled.
8 =
Expander trouble report enabled.
Segment 4 (Circle Numbers To Program)
1 =
Failure To Communicate report enabled.
2 =
Log Full report enabled.
3 =
Autotest report enabled.
4 =
Start and End Programming report enabled.
5 =
End Download report enabled.
6 =
Sensor Low Battery report enabled.
7 =
Sensor Missing report enabled.
8 =
First to Open / Last to Close enabled.
Segment 5 (Circle numbers to program)
1 =
Lost Clock service LED enable.
2 =
Zone Doubling enable.
3 =
Disable on-board eight zones.
4 =
Enables two trips on the same cross-zone to activate the alarm.
5 =
Disables bypass reports for force armed zones
6 =
Reserved.
7 =
Clock uses internal crystal.
8 =
Disable Temporal Siren on Fire (
Do not disable on UL listed systems
)
Segment 6 (Circle numbers to program)
1 =
Enable 2-wire Smoke Detector.
2 =
Reserved.
3 =
Enable Zone Activity in Hours (not Days)
4 =
Enable Daylight Savings Time (DST)
5 =
Reserved
6 =
Disable Clean Me report
7 =
Disable Start/End Test report
8 =
Enables Auto LED Extinguish
Segment 7 - RESERVED
L
38
20
SWINGER SHUTDOWN COUNT
1
_
Содержание NetworX Series
Страница 1: ...NetworX Series NX 8V2 Control Panel Installation and Startup ...
Страница 5: ...NX 8V2 Control 5 IV NX 8V2 WIRING DIAGRAM ...
Страница 59: ...SYSTEM NOTES ...