GE 16X PTZ Camera
Installation Manual
12
Figure 13. DIP switch locations
To set protocol (SW101) and baud rate parameters (SW104), do the following:
1. Turn the camera off.
2. The SW104 DIP switch on the bottom of the camera (
Figure 14
on page 12) sets the baud rate. Use
Table 3
to find the correct sequence of 1s (on) and 0s (off) for the baud rate that you want to use.
Note:
SW104 is located next to the 8-bit camera ID DIP switch.
Figure 14. SW104
Note:
The baud rate for Digiplex 422 is 4800. The baud rate for IMPAC RS-485 is 9600. The baud rate for ASCII is 9600.
The Pelco P/D protocol requires no specific baud rate.
Table 3.
SW104 baud settings
Switch position
Baud
Switch position
Baud
0, 0, 0, 0
9,600 bps
0, 1, 0, 0
19,200 bps
0, 0, 0, 1
1,200 bps
0, 1, 0, 1
38,400 bps
0, 0, 1, 0
2,400 bps
0, 1, 1, 0
57,600 bps
0, 0, 1, 1
4,800 bps (default)
0, 1, 1, 1
115,200 bps
Camera ID
switch
Baud rate
switch (SW104
Protocol
switch (SW101)
On (1)
Off (0)