Chapter 3. Installing the Transducer Assemblies
44
T5 Flare Gas Transducer Installation Guide
3.6 Aligning the Transducers (Extended Velocity Range) (cont.)
4.
Slide the
locking collar
over the downstream transducer to the cavity on top of the guide plate. Align the 6°
mark on the top of the collar with the line on the transducer (see
below). Then, tighten the collar set
screws until the collar is secured to the transducer.
Figure 11: Installing the Locking Collar
5.
Check to see if the 0° mark on the side of the locking collar is aligned with the line on the guide plate. If they
are not aligned, then loosen the nuts on top of the barrel flange and rotate the transducer assembly until the two
lines are aligned (see
below). Then, re-tighten the nuts.
Figure 12: Locking Collar 0° Mark Aligned with Guide Plate Line
Downstream
Transducer
Collar 6° Mark
Line on Transducer Tube
6° Mark
0° Mark
Downstream
Transducer
Collar 0° Mark
Guide Plate Line
Nuts on Flange