The luminaire can be installed at a fixed surface with two brackets.
(See Fig.1)
Step by Step:
1) Confirm the installation room, and refer to section VI the size of
luminaire.
2) Install the two brackets to fixed surface with screws of provided.
(Ensuring that the screws don’t touch any obstructions such as
cables, water pipes, etc.)
3) Fix the luminaire to the two brackets directly.
4) Adjust luminaire to desirable position.
5) Refer to section V for installation of lamp.
2. Series connection
Fixture can be connected by two ways, and the maximum
allowable connection quantity is 10 pieces. (See Fig.2)
In addition to above introduction, we are also providing multiple combinations to customer, including with/without diffuser, different lamp color
temperature, package and accessories. For detail information please contact GE’s sales team or distribution agency.
PRODUCT DIMENSIONS AND OUTLINES (mm)
VI. PRODUCT INFORMATION
PRODUCT BASIC INFO
V. MAINTENANCE / LAMP REPLACEMENT
FAILURE PARTS NEED TO BE REPLACED IF YOU INSPECT THE
LAMP EXTINCT, FLICKING OR CYCLING. ORDER THE REPLACEMENT
PART INDIVIDUALLY. CONTACT THE MANUFACTURES FOR THE
MAINTENANCE SERVICE.
LAMP REPLACEMENT
Light output is also dependent on burning time of lamp. In
applications where light levels are critical, it may be desirable to
replace lamps before the end of life. Lamp manufacturer can provide
life curve datasheet of light
output
1) Shut off power.
2) Carefully remove the diffuser if have.
3) Use one hand to push the both side of end cap and another hand
release the cover. (See Fig.3)
4) Turn 90°and remove the lamps to be replaced.
5) Re-install the luminaire in line with the requirements of qualified lamp.
6) Restore.
If lamp is handled, fingerprint, grease or oils should be removed from
lamp with isopropyl alcohol. This will remove material that will cause
whitish spotting, and premature lamp failure. Dry lamp carefully with
cotton or clean cloth.
GE T5 Starcoat ™ lamp is recommended
Notice:
Luminaires suitable for direct mounting on normally
flammable surfaces.
Wiring Series
connection
Coupler Series
connection
(Fig.1)
(Fig.2)
• Please note the lamp type, wattage shall be same as the indi-
cation of the product label.
• Cut off the power before installation, and let lamp and fixture
cool down.
• The diffuser is frangible, cannot press hardly.
WARNING
(Fig.3)
Description
Lamp & Power
Rating
Voltage
Power
Current
Frequency
PF
Max Series
Current
Recommended
GE lamp
Size mm (LxWxH)
DMS 08 Series
T5 LFL 1x8W
220-240V~
0.075A
50/60Hz
0.95
0.85A
F8T5
318x24.5x47
DMS 14 Series
T5 LFL 1x14W
220-240V~
0.13A
50/60Hz
0.95
1.4A
F14W/T5/HE
579x24.5x47
DMS 21 Series
T5 LFL 1x21W
220-240V~
0.11A
50/60Hz
0.95
2A
F21W/T5/HE
879x24.5x47
DMS 28 Series
T5 LFL 1x28W
220-240V~
0.14A
50/60Hz
0.95
1.5A
F28W/T5/HE
1179x24.5x47