0150-0255C
6-1
Kalatel VDR
6
RS-232 R
EMOTE
P
ROTOCOL
The RS-232 protocol command structure uses “Start of Text” (S
x
) and “End of Text” (E
x
) characters to
identify the beginning and end of command sequences.
The VDR supports the following command sequences:
ASCII Command String
Command
ASCII String
Bytes in Hexadecimal
Play Forward
S
x
PLF
E
x
02 46 50 4C 03
Record
S
x
REC
E
x
02 52 45 43 03
Stop
S
x
STO
E
x
02 53 54 4F 03
Pause
S
x
PAU
E
x
02 50 41 55 03
Fast Forward
S
x
FWD
E
x
02 46 57 44 03
Rewind
S
x
REW
E
x
02 52 45 57 03
Frame Forward
S
x
FAD
E
x
02 46 41 44 03
Frame Reverse
S
x
RAD
E
x
02 52 41 44 03
Play Reverse
S
x
RPL
E
x
02 52 50 4C 03
Increase Speed
S
x
ISP
E
x
02 49 53 50 03
Decrease Speed
S
x
DSP
E
x
02 44 53 50 03
Search
S
x
SEA
E
x
02 53 45 41 03
Up Arrow
S
x
ARU
E
x
02 41 52 55 03
Down Arrow
S
x
ARD
E
x
02 41 52 44 03
Left Arrow
S
x
ARL
E
x
02 41 52 4C 03
Right Arrow
S
x
ARR
E
x
02 41 52 52 03
Menu
S
x
MEN
E
x
02 4D 45 4E 03
Enter
S
x
ENT
E
x
02 45 4E 54 03
Set Clock
See instructions for setting clock in the following section.
Note:
All byte values shown in hexadecimal.
NOTE
Содержание Kalatel 0150-0255C