background image

Adding/Replacing Sensors

20

Home and Away

If you will be away from home or unable to acknowledge medication reminders it’s necessary to 

temporarily turn them off.

¾

When you’re Away from home:

Š

Press the Power/Home/Away button. The system announces “Medication Reminder Off”. If 

the Activity Check is scheduled it will be turned off as well. The Power/Home/Away button 

will blink when Medication Reminders are off.

¾

When you return Home:

Š

Press the Power/Home/Away button. The system announces “Medication Reminder On.” If 

the Activity Check is scheduled it will be turned on as well.

Adding/

Replacing 

Sensors

CareGard allows up to 24 sensors to be learned into the system. There are two methods for add-

ing a sensor to the system. The first method uses the menu button on the back of the panel, the 

second uses the programming buttons.

Supervised vs. Not Supervised

Most sensors supported by CareGard can be programmed to be supervised or not supervised. The 

panel monitors supervised sensors and sounds trouble beeps or turns the Status light on when 

there is a problem with the sensor.
In most situations sensors should be left in the Supervised state. Portable panic sensors should be 

Not Supervised.

To Add or Replace a Sensor using the Menu Button on the back of 

the Panel

Note  

Pressing the Menu button cycles through 5 functions; Phone Test, Sensor Test, Medication Reminder, 

Add Sensors and Delete all Sensors. The panel will announce the current function each time the button 

is pressed.

Important !  

It is necessary to move quickly between the steps when adding sensors. Read these steps carefully 

before attempting to add a sensor. You may have as little as 5 seconds to move between steps.

The following table describes how to program each type of sensor. For complete programming 

and mounting instructions see the 

Installation Instructions

 for the device.

Table 7: Programming Sensors

Sensor Type

To Program

Personal Help Button

Pendant Help Button

1. Repeatedly press the Menu button on the back of the panel until the panel announces “Add 

sensor. Press Status to select.”

2. Press the Status button on the front of the panel.
3. Press the button on the sensor.
4. Repeatedly press the Power/Home/Away button until you hear the sensor type you want.

Personal Help Button type possibilities:

Emergency Sensor type not supervised

Emergency Sensor type supervised

5. Press the Status button to accept the sensor.

The system will announce the sensor name, type and number.

Содержание CareGard 60-883-95R

Страница 1: ...g GE Interlogix Installation Instructions 466 1938 Rev C May 2003 CareGard Part No 60 883 95R www GE Interlogix com ...

Страница 2: ...line and place a call in an emergency situation It must be able to do this even if other equipment telephone answering system computer modem etc already has the telephone line in use To do so alarm dialing equipment must be connected to a properly installed RJ31X jack that is electrically in series and ahead of all other equipment attached to the same tele phone line Proper installation is depicte...

Страница 3: ...ivate a portable panic sensor 4 To activate the panel Call button 4 After initiating a call the panel will 5 Programming 5 Access Codes 5 Master Access Code 5 Utility Access Code 1 Dealer Code 5 Utility Access Code 2 Installer Code 5 Entering Program Mode 6 Setting the Clock 6 Changing an Access Code 6 Programming Options 7 Option 1 Panel Voice 8 Option 2 Account Number 9 Option 3 Primary Phone Nu...

Страница 4: ... 30 Demo Mode 16 Option 31 Programming Report 16 Option 32 Supervisory Time 16 Option 33 Modem Sensitivity 16 Option 34 VOX Mic Gain 16 Option 35 VOX Gain Range 16 Option 36 Manual Mic Gain 17 Option 37 VOX Receiver Gain 17 Option 38 Alarm Cancel Timeout 17 Option 39 No Audio on Alarm Cancel 17 Option 40 Report Medication Failures at Supervisory Time 17 Option 41 Activity Check 17 Option 42 Siren ...

Страница 5: ...AC Power 23 Backup Battery 23 Replacing the Backup Battery 24 Sensor Low Battery 24 Sensor Supervisory Failure 24 Automatic Phone Test 25 Sensor Testing 25 Phone Communication Testing 25 Phone Test 25 Central Station Communication 25 Pager Communication 26 Voice Event Notification 26 Remote Phone Operation 26 Troubleshooting 28 ...

Страница 6: ...dard Class II 9 VAC 700 mA Power Transformer Wrist Panic Digital Alarm Communicator System UL 1635 These options are required only if the system is set up for central station reporting Option 3 Primary Phone Number programmed Option 10 Phone Mod 1 set to 0 or 1 Option 14 Auto Phone Test set to 001 Option 15 RF Timeout set to 4 hours Option 17 AC Power Failure Report set to 15 minutes Option 18 CPU...

Страница 7: ...allation site The sensor can be worn around the neck with a removable cord included or on the user s belt with an optional leather belt holster The panel can be pro grammed to supervise the Pendant Panic A Repeater 60 615 10 319 5 can be added to the CareGard System in order to boost the range of the wireless sensors Smoke Alarms 60 848 02 95 can be added to the CareGard System to provide warning ...

Страница 8: ...Grabbers or the installation of an RJ31X jack are also acceptable methods of obtaining Line Sei zure Line Seizure This method requires that the panel be wired ahead or in front of all other phones answering machines computers or any other devices on the phone line This allows the panel to take over seize the phone line even if another device on the line is in use 1 Plug the smaller end of the incl...

Страница 9: ...ouncements from the speaker and the volume during a 2 way talk session Adjust the built in speaker volume using the Volume button on the front of the panel Each time the Volume button is pressed it increases the speaker volume one level and announces the volume level Adjust the volume the same way during a 2 way talk session Basic Operation The main function of the CareGard system is to respond to...

Страница 10: ...or if the sys tem is set up for 2 way audio This depends on Options 24 and 26 Programming The CareGard system can be customized for different installation situations by setting certain options See the Programming Options section of this manual for a descriptions of all the options and their settings Programming involves these basic steps 1 Enter Program Mode 2 Set the Clock 3 Change Access Codes 4...

Страница 11: ... an Access Code To change an Access Code 1 Enter Program Mode 2 Verify the Access Code Length Option 28 3 Press the Add button from the Start Menu 4 Press the Access Code button until you hear the name of the Access Code you want to change 5 Press the Done button to select the Access Code 6 Using the numbered keys enter the new access code The panel will repeat the Access Code after the last digit...

Страница 12: ...g sequence To change an option setting Press Add or Delete then press Option repeatedly until you hear the option you want changed Or Press Add or Delete Option then enter the 2 digit option number using the red numbered keys Table 1 Numbered Options Settings No Function Default Range Desired Setting 1 Panel Voice On On Off 2 Account Number 00000 0 9 A F 3 Primary Phone Number Off 26 digits 4 Seco...

Страница 13: ...l Mic Gain 64 01 64 37 VOX Receiver Gain 6 01 10 38 Alarm Cancel Timeout 005 minutes 003 254 255 Off 39 No Audio after Cancel Off On Off 40 Report Medication Failures At Supervisory Time Off On Off 41 No Activity Hours Off 02 48 42 Siren Time Out 4 minutes 002 254 43 House Code A A P Option 1 Panel Voice Range On Off Default On When this option is Off and Option 21 is set to 2 the panel will not a...

Страница 14: ...one Number use the Add button to enter a symbol Use the Delete button to enter a symbol Use the Test button to enter a pause To program a Secondary Phone Number 1 Press Add 2 Press Option 3 Press 0 then 4 4 Enter the Number using the numbered but tons and the Add Delete and Test buttons as necessary 5 Press Done Option 5 Numeric Pager Voice Event Notification Phone Number Range 26 Digits Default O...

Страница 15: ...s you set a unique 5 digit code that is required for initiating CareGard Remote Programmer sessions or sets the code to its default off The code must be 5 digits long and can range from 00000 to 99999 The Downloader Code must match the downloader access code in the CareGard Remote Programmer account to perform downloader sessions Note The Downloader Code should always be changed from the default s...

Страница 16: ...wer Restorals Failures Medication Reminder Activity Timer and Phone Test Pager 09 Same as 08 plus Alarms Pager 10 Alarms only See Options 5 and 12 Voice Event Notification Option 12 Numeric Pager Voice Event Notification Phone Mod 3 Range 08 10 Default 10 Determines what content and how format the panel should report through a Numeric Pager Voice Event Notification Phone Number Option 5 if one is ...

Страница 17: ...or more information The Timeout can be set from 02 to 24 hours Entries must be 2 digits Note Setting this feature to 2 hours may cause false reports RF Timeout must be set to 4 hours for ETL UL 1635 listed systems To program Auto Phone Test 1 Press Add 2 Press Option 3 Press 1 then 4 4 Enter the desired Auto Phone Test days using the numbered buttons 5 Press Done Option 16 Manual Phone Test Range ...

Страница 18: ...g Ring Range On Off Default 1 Determines when the panel answers a remote phone access call Depending on whether an answering machine exists at the panel location off site access to the panel can be achieved with a series of phone calls or just one Table 5 shows the available settings For off site access where an answering machine exists the user must perform the following steps 1 Call the panel lo...

Страница 19: ...ess 2 then 3 4 Press Done Option 24 Audio Verification Range On Off Default On Determines whether the system can perform 2 way voice audio sessions with a central station operator on or not off Note If this option is off Option 26 AVM Mode will not work To Add or Delete Audio Verification 1 Press Add or Delete 2 Press Option 3 Press 2 then 4 4 Press Done Option 25 Trouble Beeps Range On Off Defaul...

Страница 20: ...ing the access code length resets the Master Utility 1 and Utility 2 access codes to their respective defaults as described in Table 6 Note If the customer wants the Access Code Length changed it should be set before programming any new unprogrammed access codes whenever possible To program Access Code Length 1 Press Add 2 Press Option 3 Press 2 then 8 4 Enter the desired Access Code Length using ...

Страница 21: ...e panel clock must be set to the correct time for this option and Option 14 Auto Phone Test to work correctly To program Supervisory Time 1 Press Add 2 Press Option 3 Press 3 then 2 4 Enter the desired Supervisory Time using the Hours and Minutes buttons 5 Press Done Option 33 Modem Sensitivity Range On Off Default Off Determines whether the modem sensitivity is set to normal off or high on Note T...

Страница 22: ... within the Alarm Cancel Timeout period an alarm cancel report is generated Note If this option is Off alarms cannot be cancelled and the panel will not announce or press Status to cancel To program Alarm Cancel Timeout 1 Press Add 2 Press Option 3 Press 3 then 8 4 Enter the desired Alarm Cancel Timeout using the numbered buttons 5 Press Done Option 39 No Audio on Alarm Cancel Range On Off Default...

Страница 23: ... num ber of hours selected The user must press the Status button or activate an activity sensor at least once during the selected Activity Check time For example if the Activity Check is set to 10 at least every 10 hours the user must press the Status button on the panel or activate an activity sen sor Pressing the Status button resets the timer and the user has another 10 hours to press the Sta t...

Страница 24: ...announces Medication reminder one time is off press Power to change Note Pressing the volume button at any time when setting a medication reminder turns it off 3 Press the Power button until you hear the correct time for the medication reminder The time starts at 6 00 A M and cycles through every half hour 4 Repeat steps 2 3 for each reminder that needs to be set To turn a Medication Reminder off ...

Страница 25: ... Supervised state Portable panic sensors should be Not Supervised To Add or Replace a Sensor using the Menu Button on the back of the Panel Note Pressing the Menu button cycles through 5 functions Phone Test Sensor Test Medication Reminder Add Sensors and Delete all Sensors The panel will announce the current function each time the button is pressed Important It is necessary to move quickly betwee...

Страница 26: ... press the Power Home Away button until you hear the panel announce Press status to accept Water Sensor type supervised 6 Press the Status button to accept the sensor The system will announce the sensor name type and number Smoke Alarm 1 Repeatedly press the Menu button on the back of the panel until the panel announces Add sensor Press Status to select 2 Press the Status button on the front of th...

Страница 27: ...The system will announce the sensor name type and number Table 8 Programming Sensors Sensor Type To Trip Sensor Type Options Personal Help Button Press the help button on the sensor Emergency Sensor Type Not Supervised Emergency Sensor type Supervised Pendant Help Button Press the help button on the sensor Emergency Sensor Type Not Supervised Emergency Sensor type Supervised Door Window Sensor Wit...

Страница 28: ...urns off 2 After 4 minutes a non reporting AC fail report will be placed in the event buffer Note If Status is pressed during an AC power failure the sys tem will announce AC power failure and the sys tem will stop beeping for 4 hours 3 If Option 25 Trouble Beeps is enabled six trouble beeps will sound once a minute 4 After the AC Power Failure Report time Option 17 expires the panel reports an AC...

Страница 29: ...r within the programmed RF Timeout Option 15 the following occurs 1 The panel sends a Sensor Supervisory Failure report to the central station 2 The Status light turns on 3 If Option 25 Trouble Beeps is enabled six trouble beeps will sound once a minute START MENU MAIN MENU Delete press Delete To delete an option or access code and follow voice prompts Cancel Cancel Minutes See Note DONE then If y...

Страница 30: ...o grammed the panel says Function not available 5 Press Status The panel says Sensor test OK For testing instructions for other sensors see the Installation Instructions for the sensor Phone Communication Testing Perform phone tests to check the programmed phone numbers off site phone operation and phone communication between the panel and the central station While the following tests are similar ...

Страница 31: ... announces Time is x xx sensor xx panic alarm If the button is not pressed and the call is ended the panel will call back 8 times Note Pressing 5 on the phone at this point will start a 2 way session with the panel See Table 10 for the remote phone commands Note You must terminate the call by pressing Otherwise the panel may not disconnect from the phone line for up to 2 minutes 5 After listening ...

Страница 32: ...Phone Communication Testing 27 Table 10 Remote Phone Operation System Function Phone Command Talk 0 or 1 2 Way Conversation 2 Listen 3 or 6 Terminate Session ...

Страница 33: ...ec tion for information on correcting the problem The system is announcing System phone commu nications failure Verify the phone line is connected correctly Verify a Phone Number Option 3 5 is programmed correctly If testing a voice event notification number the phone must be answered in order for the phone test to pass The system is announcing System low battery Make sure the battery is fully cha...

Страница 34: ...anual Phone Test 12 Modem Sensitivity 16 N No Line Seizure 3 Numeric pager 11 Numeric Pager Voice Event Notification Phone Mod 3 11 Numeric Pager Voice Event Notification Phone Number 9 O Option 7 P Pager 11 Panel Voice 8 Pendant Panic 4 PHONE jack 3 Phone Lock 10 Phone Mod 1 10 Phone Mod 2 11 Power light 23 Primary Phone Number 9 Program Mode 6 Programming 5 Programming Report 16 R Radionics D660...

Отзывы: