![GE Interlogix 260 Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/ge-interlogix/260/260_installation-manual_571906013.webp)
GE Contactless Medium Read-Range Reader Model 260
9
FIGURE 6: Parking Entrance/Exit Application B
In Application A, the back-to-back and (if used) vertical gap guidelines
above must be observed. Remember to mount all readers (and all other
structures) before tuning the reader.
In Application B, successful installation requires close attention to
electrical noise from the gate control mechanism (and its associated
wiring) that may cause reader-to-reader signal interference.
Gate
Ctrl
Gate
Ctrl
IN
OUT
Readers
Reader-Control
Gap