GDS 10+ Oxymed Fixed or Transportable

Channels 

Single Channel 

Measurements

Oxygen – 0 ~ 25% vol.

Channel Outputs

Analogue output 4–20mA – option 1~5 volts. 250 ohms max load

Relays 

S.P.C.O. per relay – auto reset

RL1 – 3A/230v AC control relay

RL2 – 1A/24v DC signal relay

Single Stage Alarm

Oxygen Enrichment

Power

230/115v AC

12 to 30v DC – optional

Panel Indication

Alarm – Red LED

Audible Alarm 

Auto reset 75dBs @ 1m

Operating Temperature 

–10 to + 50° C

Storage Temperature

+5° C to + 55° C

Humidity 

0–95 non condensing

Ingress Protection

IP64 Weatherproof

Dimensions

H–147 W–145 D–100mm (AC Version)

Weight 

0.76KG (AC Version)

Enclosure Material

ABS Flame Retardant FR40 – Lid Screws M4SS

Finish – Signal White RAL 9003

Notes

Mains lead supplied as standard. For additional information, please see C1798

SPECIFICATION

GDS Technologies Ltd operates under an integrated quality, health and safety and environmental management system certified to ISO 9001, ISO 45001 and ISO 14001 by NQA Certification Ltd. 
This document is not contractual and the equipment specification may be modified at any time without prior notice.

  

E:

 sales@gds–technologies.co.uk  

T:

 +44 (0)113 286 0166

GDS TECHNOLOGIES LTD | FUSION POINT | ASH LANE | GARFORTH | LEEDS | LS25 2GA | UK

www.gds–technologies.co.uk

GDS 10+ OXYMED  

OXYGEN MONITOR

Specification Sheet Ref C1821B

Содержание 10+ OXYMED

Страница 1: ...in the vicinity of assisted breathing apparatus requiring oxygen cylinders or dedicated oxygen supply lines The compact style offers functionality for the monitor to be used as a fixed or a transportable device boasting further benefits for quick installation via a standard wall socket outlet GDS 10 OXYMED OXYGEN MONITOR ...

Страница 2: ...he indicator Ensure that the supply is OFF before making any connections and wire only in accordance with the terminal detail Calibration factory set 1 Connect a digital voltmeter miIIivolt range to the X and Y test terminals the CV is preset in the current source mode 2 Remove the sensor terminal connector from the PCB J4 or yellow wire and adjust the 4mA potentiometer for 4mA 4mV 3 Where a digit...

Страница 3: ...r bedding within the area If you suspect contamination remove items outside for airing 3 Siting the Equipment Siting of the equipment should be chosen with regards to the following points Away from sources of heat with room for adequate air circulation Convenient to a 230v mains socket outlet Within easy access and audible distance of local staff Within the target area at 1 to 1 5m height 4 Operat...

Страница 4: ...147 W 145 D 100mm AC Version Weight 0 76KG AC Version Enclosure Material ABS Flame Retardant FR40 Lid Screws M4SS Finish Signal White RAL 9003 Notes Mains lead supplied as standard For additional information please see C1798 SPECIFICATION GDS Technologies Ltd operates under an integrated quality health and safety and environmental management system certified to ISO 9001 ISO 45001 and ISO 14001 by ...

Отзывы: