2. SMS
- 40 -
01 Aug 2018
User Manual for LPU-1000 LED Player Unit
Figure 24: SNMP Configuration - Storage
2.3.5.3.5 Storage
1
[Storage]
On the
SNMP Configuration
, select
Storage
. A new window opens as
seen in
above.
2
[HDD Missing and SMART Error]
Check the corresponding storage devices
to activate the Trap.
NOTE: When Trap is On, a trap will be sent to the SNMP Manager
if the system cannot detect the specified device.
3
[HDD Temperature Threshold]
Set the desired threshold temperature for respective storage device by
using the
[▲]
and
[▼]
buttons. Activate the Trap by checking the
checkbox opposite the corresponding storage device.
NOTE: When t he Trap is On, a trap will be sent to the SNMP
Manager when the threshold temperature is reached.
4
[RAID Device missing and
degraded status]
Activate the Trap by checking the checkbox opposite
RAID Device
.
NOTE: When t he Trap is On, a trap will be sent if the
RAID Device is missing or degraded.
5
[Mount Data Storage]
Activate the Trap by checking the checkbox opposite
Mount Data
Storage
.
NOTE: When t he Trap is On, a trap will be sent if the data storage
is not mounted on the system.
2
4
5
6
1
3
Содержание LPU-1000
Страница 59: ...2 SMS User Manual for LPU 1000 LED Player Unit 01 Aug 2018 59 Figure 40 Cue Editor 3 4 2 6 5 7 4 8 4...
Страница 81: ...3 CONTROL PANEL User Manual for LPU 1000 LED Player Unit 01 Aug 2018 81 Figure 57 SMS interface...
Страница 161: ...7 APPENDIX 161 USER MANUAL FOR LPU 1000 LED PLAYER UNIT 5 Mar 2018 Figure 148 MDA Configuration Manager...