11. AIB-2000 WEB INTERFACE
11 AIB-2000 WEB INTERFACE
The AIB-2000 provides the user with a built-in web interface to access its functions for control, setup and
monitoring. Interface functions include switching input for 7.1 OUTPUT, selecting output for microphone,
setting devic
e’s IP and Submask, setting a password and monitoring device’s digital input state and internal
temperature. AIB-2000 must be connected to a wired or a wireless network via the
ETH
port. The device used
for accessing the web interface must be in the same network as the AIB-2000.
11.1 Default Access Credentials
Default factory network settings for AIB-2000 are as follows:
▪
IP Address:
192.168.0.8
▪
Network mask:
255.255.255.0
▪
Gateway:
192.168.0.1
▪
Username:
Please contact GDC for the username and password of the web interface
▪
Password:
Please contact GDC for the username and password of the web interface
11.2 Resetting AIB-2000 to Default Factory Settings
To reset the network settings, username and password to factory defaults; follow the steps mentioned below:
1. Turn OFF the AIB-2000 device.
2. Press and simultaneously hold the
7.1 ANALOG
and
NS XLR
buttons and turn ON the device.
Figure 6: Reset to Default Factory Settings (1)
3. Keep these buttons pressed until indicators above the
7.1 ANALOG
,
NS RCA
and
NS XLR
buttons are simultaneously lit.
4. Release the
7.1 ANALOG
and
NS XLR
buttons. The AIB-2000 device is now reset.