Introduction
Thanks for choosing the Vision’s wireless Arrival Sensor of the home security device. This
sensor is a Z-Wave™ PLUS enabled device (interoperable, two-way RF mesh networking
technology) and is fully compatible with any Z-Wave™ enabled network and it’s security
framework. Every mains powered Z-Wave PLUS enabled device acts as a signal repeater and
multiple devices result in more possible transmission routes which helps eliminate “RF
dead-spots”
Z-Wave™ PLUS enabled devices displaying the Z-Wave™ PLUS logo can also be used with it
regardless of the manufacturer, and ours can also be used in other manufacturer’s Z-Wave™
PLUS enabled networks. This sensor
assigns everyone an unique ID then you could take care
of your family to send you any instant notification when they are coming home or leaving home,
also you could interact some specific scenarios with specific persons When the device is
secure included into Z-Wave network, above communication will be encrypted.
ARRIVAL
SENSOR supports SECURITY S0 / SECURITY S2 UNAUTHENTICATED / SECURITY S2
AUTHENTICATED.
Product Description and Specification
Specification:
Package Content:
Protocol: Z-Wave™ (ZM5101)
Frequency Range:
865.22MHz (ZA1501IN-5)
868.42MHz (ZA1501EU-5)
869.00MHz (ZA1501RU-5)
908.42MHz (ZA1501US-5)
916.00MHz (ZA1501IL-5)
919~923MHz (ZA1501KR-5)
919.80MHz (ZA1501HK-5)
922~926MHz (ZA1501JP-5)
921.42MHz (ZA1501BR-5)
Operating Range: Up to 100 feet line of sight
Operating Temp.: -10°C~ 60°C (14°F ~140°F)
1pc
1pc
1pc
Arrival sensor
Micro USB Cable
Operation manual
Z-Wave Command Classes
:
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_BATTERY
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_NOTIFICATION_V8
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_TRANSPORT_SERVICE_V2
COMMAND_CLASS_VERSION_V3
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Z-Wave S2 Support Command Class:
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_BATTERY
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_NOTIFICATION_V8
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_VERSION_V3
COMMAND_CLASS_WAKE_UP_V2
Notification V8 Type
TYPE
EVENT
Notification
Type
System (0x09)
Heartbeat (0x05)
Clock (0x0B)
Timer Ended (0x02)
(Table 1)
V1 Alarm:
TYPE
VALUE
V1 Alarm
Type
0x09
0xFF
0x0B
0x00
(Table 2)
Configuration Command Class:
Byte
Value
Parameter 1
1
1 ~ 127 (unsigned decimal) Seconds
(default: 2 (=16seconds x 2))
(Table 3)
(P.S.: This is the definition how long ZA1501-5 will contact
Gateway for having a synchronic information. The basic
interval time is 16 seconds, the synchronic time will be the
basic interval time by Parameter 1’s value.)
-1-
-2-