StellarMark IFII-Series User Manual   

Rev.5.0

 

70 

 

Step 2. 

Position the mouse on the ”G-Mark Lib” and right-click, properties 
for the ”G-Mark Lib” appears then press the properties. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Step 3. 

Click “Compatibility” tab and select checkbox “Run this program as 
an administrator” 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание IFIIS 20JFL

Страница 1: ...4F No 236 Fude 2nd Rd Xizhi Dist New Taipei City 22151 Taiwan 886 2 6616 6692 Fax 886 2 2694 6875 Version 5 0 Released Feb 2020 StellarMark IFII Series User Manual IF Series ...

Страница 2: ...larMark IFII Series User Manual Rev 5 0 i Release Note Version Release Date Change Note 4 0 Jan 2019 Modify chapter 4 2 Pyramid focus tool Modify chapter 4 3 Manual focus tool 5 0 Feb 2020 Add IFIIS models ...

Страница 3: ... Foot Print 24 CHAPTER 4 WORKING DISTANCE 26 4 1 Recommended Working Distance 26 4 2 Pyramid Focus Tool 27 4 3 Manual Focus Tool 31 CHAPTER 5 MACHINE SETUP 33 5 1 Cable connection 34 5 2 Powering Up the Machine 36 5 3 Control Unit operating instruction 38 CHAPTER 6 SOFTWARE SETUP 39 6 1 Recommended Computer Configuration 40 6 2 Software Installation for Windows System 41 6 3 Software Installation ...

Страница 4: ...RROR MESSAGE 92 CHAPTER 9 EXTERNAL CONTROL 94 9 1 I O Pin Assignment 95 9 2 Laser Working Flow Chart 98 9 3 Laser Reaction Timing Diagram 99 CHAPTER 10 BASIC MAINTENANCE 101 10 1 Regular Spot Check 102 10 2 Cleaning the Focal Lens 103 CHAPTER 11 APPENDIX 106 11 1 IFII Series Specification 107 ...

Страница 5: ...StellarMark IFII Series User Manual Rev 5 0 1 Chapter 1 Safety Principles of a Fiber Laser Safety Ratings The Safety Interlock System Safety Labels Safety Measures Operating Environment ...

Страница 6: ...ology fiber laser is immune of misalignment and does not request any adjustment during operation 1 2 Safety Ratings StellarMark IFII series laser marker emits intense and INVISIBLE laser radiation with a wavelength of 1064nm 1micron for fiber laser in the infrared spectrum The IFII series is designed with laser safety rating of CDRH Class 4 and has been equipped with a red guidance pointer This re...

Страница 7: ...ards all fixed or removable covers that allow access to laser beam must have appropriate laser warning labels attached to them These warning labels must be clearly visible to the operator prior to removing the cover Additional labels must be applied to the interior of the machine and visible to operators when covers are removed A label clearly displaying the manufacturer s name date of manufacture...

Страница 8: ...f all the safety labels and their locations on the machine Product Label This label is located at the side panel of machine All the product information such as Serial Number Model Number Laser Power and Power Consumption information can be found here When inquiring any tech support always provide the service representatives with the information on this label ...

Страница 9: ...StellarMark IFII Series User Manual Rev 5 0 5 ...

Страница 10: ...StellarMark IFII Series User Manual Rev 5 0 6 ...

Страница 11: ...out the equipment The following warning labels are placed on the laser system for your safety Do not remove these labels for any reason If the labels become damaged or have been removed for any reason do not operate the laser system and immediately contact GCC local representative or e mail us for a replacement CDRH Label This label indicates the class level of CDRH ...

Страница 12: ... with all the necessary information to be aware of in every operation Invisible laser radiation when operation Avoid eye or skin exposure direct to laser radiation The scan lenses are fragile Take extra caution when installing and cleaning Do not leave the machine unattended during operation Safety glasses required Dust mask required Read and understand operator s manual before using this machine ...

Страница 13: ...ourself with the warning labels located on both your laser system and in this manual Never leave the machine unattended during the laser cutting and marking process The laser may ignite combustible materials A well maintained fire extinguisher and operational smoke or fire detector should be kept in the vicinity of the machine Resulting debris from laser cutting are very dangerous and may cause fi...

Страница 14: ... and maintain your machine according to our cleaning and maintenance instructions Doing so will ensure a machine that will operate effectively and safely over a long period of time 1 6 Operating Environment Please follow the guidelines when considering a suitable location to set the LaserPro StellarMark IFII series Improper work environments may lead to operational malfunction and or unsafe workin...

Страница 15: ... temperature is near the dew point Setup the machine to be apart from the wall for at least 40cm 1 5 feet Choose a flat surface that is not exposed to high levels of vibration Be sure that your mounting platform has been securely fastened to the table stand or floor Choose a location that is large enough to accommodate the machine the computer and a work storage table Have a fire extinguisher clos...

Страница 16: ...StellarMark IFII Series User Manual Rev 5 0 12 Chapter 2 Unpacking Content Unpacking and Unloading Accessories Checklist ...

Страница 17: ...Control Unit software and all of the necessary accessories in an accessory kit NOTE Please save the original shipping crate in case it is needed for future transportation or product service Control Unit Accessory Kit Laser Marker To prevent damage to the machine or personal injury please get assistance when loading and unloading the shipping crate WARNING ...

Страница 18: ...anual Rev 5 0 14 2 2 Accessories Checklist Please check to make sure that all of the following items are included within the accessory box If any of the following items are missing immediately contact your local GCC representatives ...

Страница 19: ...its Package 1 8 Lens Parameter List 1 9 GCC Promise Card Set 1 10 Focus Tool 1 11 1064nm Goggle YG3 900 1 12 AC Power Cable Europe 1 AC Power Cable US 1 AC Power Cable Australia 1 13 USB Cable 1 8M 1 14 Stainless Steel 9 x 5 5cm 2 15 Door Switch Short Circuit Wire 5cm 1 16 M6 Screw Plastic Foot 4 17 Nut M6 x T5 x S10 4 18 System Key 1 19 I O Terminal Platform 5ESDVM 10P 1 20 Laser Head Power Cable...

Страница 20: ...StellarMark IFII Series User Manual Rev 5 0 16 Chapter 3 Mechanical Overview Laser Marker Control Unit Foot Print ...

Страница 21: ...eries User Manual Rev 5 0 17 Before complete the installation it is a good idea to become more familiar with the machine s features and components 3 1 Laser Marker 3 1 1 LED Panel LED Panel Laser Tube Scan head Scan Lens ...

Страница 22: ...r On and Power on of the laser marker Over Temp When the red LED light is on the laser marker will stop firing Please turn off the master power of the laser marker and re start it when the operating temperature is dropped below 35 Laser On When laser is firing the red LED light is on Power On When the laser is power on and the green LED light is on ...

Страница 23: ... 110 IFII 60JFL 180 70x70mm 110x110mm 180x180mm The smaller field size scan lens will produce a smaller spot size with higher marking resolution The larger field scan lens will produce a larger spot size with lower marking resolution NOTE Scan lens is protected by a cover to prevent damage during shipment Always remove the cover prior to use WARNING The scan lens is very fragile and must be carefu...

Страница 24: ...ton to stop the laser in an emergency To reset this button rotate it to the direction of an arrow Key Switch Optical Fiber Cable Power On Signal Ready Signal Laser On Laser Marker Power USB Port Rotary Attachment Connection Port I O Terminal Mark On Fly I O Port SCSI LFC Connection Port ...

Страница 25: ...he back of Control Unit and they are the signal transmitting bridges between StellarMark and automation devices such as the conveyer for automation controls 8 Output signal pins and 8 Input signal pins are provided for any designated automation purposes WARNING Excessively tight fiber bends less than a 10 cm radius will permanently damage and possibly ignite the fiber Do not remove the two ends of...

Страница 26: ...er automation devices 3 2 3 Rotary Attachment Connector Rotary Attachment port connects StellarMark optional Rotary Attachment to IFII series laser marker it allows laser marker to process precise 360 marking on round cylindrical or torus shaped objects 3 2 4 USB Connector USB port connects laser marker to a desktop PC or Notebook ...

Страница 27: ...nual Rev 5 0 23 3 2 5 Mark On Fly Terminal Connector Mark On Fly Terminal connects laser marker to an external encoder of a conveyor system It allows IFII series laser marker to do non stop on the fly marking for mass production line ...

Страница 28: ...StellarMark IFII Series User Manual Rev 5 0 24 3 3 Foot Print 3 3 1 Laser Marker Foot Print 3 3 2 Control Unit Foot Print ...

Страница 29: ...StellarMark IFII Series User Manual Rev 5 0 25 ...

Страница 30: ...Distance Two Point Focus Finder Focus Tool 4 1 Recommended Working Distance Due to the characteristics of the scan lens a certain distance between the marking object and scan lens has to be set for an optimized output quality The working distances for different scan lens are recommended as below ...

Страница 31: ...stance on StellarMark IFII series You will find the pyramid focus tool is located on bottom of the laser marker NOTE In order to achieve the best output quality the working distance must set precisely as recommended For instance the 70x70 mm scan lens can only tolerate a distance which is 1mm different from the recommended working distance of 134mm If the working distance is set and out of the rec...

Страница 32: ...NOTE Fixed length will be varied depend on the size of scan lens The fixed length of Pyramid Ruler equals the recommended working distance and you will no need to adjust the length NOTE 1 With this tool you can always have the best working distance for different materials by just place your desired marking material on the z axis table and move the z axis table up until the mark material touches th...

Страница 33: ...2 1 Calibrate the Pyramid Focus Tool When changing to different size scan lens for different applications the calibration of Two Point Focus Finder position is required Perform the adjustment per following steps Bottom screw of Pyramid Ruler Magnetic ...

Страница 34: ... Step 2 Place the focus tool on the Z axis table or any table surface for marking objects adjust the Z axis to allow the top of the focus tool to align with the bottom of the galvo head to define the optimized focus distance Step 3 Adjust the screw of the Pyramid Focus to fit the length with manual focus tool ...

Страница 35: ...er Manual Rev 5 0 31 Step 4 Calibration is completed 4 3 Manual Focus Tool The focus tool offers you the most accurate focus distance All you need is place the bottom of the focus tool at the position of the object to be marking ...

Страница 36: ...s to allow the top of the focus tool to align with the bottom of the galvo head to create the optimized focus distance WARNING The length of Focus Tool is calibrated with corresponding scan lens Do not loosen the screws on Focus Tool to prevent incorrect focus distance ...

Страница 37: ...StellarMark IFII Series User Manual Rev 5 0 33 Chapter 5 Machine Setup Cable Connection Powering Up the Machine ...

Страница 38: ... Cable connection Step 1 Connect the Laser Marker power cable between the Control Unit and the Laser Marker Step 2 Connect the SCSI cable between the Control Unit and Laser Marker Step 3 Connect the USB cable between a PC or Laptop and the Control Unit ...

Страница 39: ... an external device like conveyor Step 5 Plug the rotary attachment cable between Control Unit and the rotary attachment device if you have this optional item in hand Step 6 Plug the software keypro to a USB port on your PC or Laptop Step 7 Remove the cover of scan lens which is shipped along with StellarMark for protection Take care not to damage the lens after removing the cover ...

Страница 40: ...proerly grounded outlet Step 2 Plug the computer to AC outlet Step 3 Connect the female end of the Control Unit power cord to the power inlet located on the Control Unit s rear side NOTE The Stellar Mark IFII series is designed to work with 110 220 VAC 50 60Hz Max 5A CAUTION Make sure both StellarMark IFII series and the computer is turned OFF before connecting either one to a power source ...

Страница 41: ... laser marker re start G Mark marking software is required due to the connection between computer and control box is disconnected when power off therefore the marking software is unable to control the laser marker firing WARNING Connection to the AC power source must be the last step after connecting all the cables between Control Unit and Laser Marker Do not pull in or out the cable while the pow...

Страница 42: ...2 Turn the key switch on so you will be able to fire the laser OFF Left ON right Step 3 Press LASER ON button The indicator light will alternately turn on and ready to lasing NOTE After finishing marking push the LASER ON button again to turn off laser output Please turn the key switch to the Off position if you would like to turn off the machine ...

Страница 43: ...I Series User Manual Rev 5 0 39 Chapter 6 Software Setup Recommended Computer Configuration Software Installation for Windows System Software Installation for MAC System Change the Series and Model Type Waveform Setup ...

Страница 44: ...using a Windows based system with the following minimum requirements Computer Configuration CPU Intel Pentium 1GHz or above DRAM 1GB RAM or above CDROM One CD ROM disk drive HDD 500 MB of free hard drive space SVGA Super VGA display 1204 x 768 min resolution Interface PC or Laptop G Mark Library marking software Software is designed for operating system Windows XP SP3 Windows 2000 VISTA 32 bit Win...

Страница 45: ...eps Step 1 Take out the G Mark installation CD from the accessories kit Step 2 Insert the G Mark installation CD into the CD ROM drive Wait a few seconds for the CD Manager to begin the Setup automatically Step 3 Click on 32 bit or 64 bit version from the menu of the G Mark installation CD depending on your operating system ...

Страница 46: ...StellarMark IFII Series User Manual Rev 5 0 42 Step 4 Set the destination directory and click Next Step 5 Select Next Step 6 Installing ...

Страница 47: ...StellarMark IFII Series User Manual Rev 5 0 43 Step 7 At 95 completion of the installation the ModelManger window will show up Step 8 Select your series model type ...

Страница 48: ...StellarMark IFII Series User Manual Rev 5 0 44 Step 9 Click OK ...

Страница 49: ... you will find Laser marking controller at the lower right hand corner on your computer screen this indicates the computer is able to communicate with StellarMark NOTE If Laser marking controller is not showing at the lower right hand corner of your computer screen G Mark will not be able to be activated Please perform the following steps ...

Страница 50: ...User Manual Rev 5 0 46 A Please go to Control and click on System B Please check if there is any USB device with warning sign from the below chart C Then click on USB Driver and click on right mouse button to update the driver ...

Страница 51: ...eries User Manual Rev 5 0 47 D Click on Browse my computer for driver software E Key in the specific path C Program Files G Mark Lib Drivers MC1 and press Next F Press Finish and now you can activate the G Mark software ...

Страница 52: ...StellarMark machines by purchasing the Parallels Desktop software which allows you to install Windows OS in MAC computers and run Windows based software under MAC computer and output with G Mark Step 1 Purchase Parallels Desktops on its official website Step 2 Install Parallels Desktops under Mac OS environment ...

Страница 53: ...StellarMark IFII Series User Manual Rev 5 0 49 Step 3 Read Software License Agreement and press Accept to continue installation Step 4 Enter your Mac OS X User Name and Password then press OK ...

Страница 54: ...StellarMark IFII Series User Manual Rev 5 0 50 Step 5 Press Active Step 6 Press OK when activation is complete ...

Страница 55: ...StellarMark IFII Series User Manual Rev 5 0 51 Step 7 Register Parallels Desktop Step 8 Press Register and OK to complete the installation of Parallels Desktop ...

Страница 56: ...rk IFII Series User Manual Rev 5 0 52 Step 9 Open Parallels Desktop in the Applications folder then choose File New Step 10 Press Install Windows from DVD or image file then press continue to install windows OS ...

Страница 57: ...StellarMark IFII Series User Manual Rev 5 0 53 Step 11 Select CD ROM drive with the Windows installation CD Step 12 Enter the Windows OS product key ...

Страница 58: ...Mark IFII Series User Manual Rev 5 0 54 Step 13 Select how you would like to run your Windows program Step 14 After the prior setting is complete the windows OS installation procedure will start automatically ...

Страница 59: ...ation for windows system to install G Mark G Mark Library NOTE Once the G Mark software installation is completed you can start to open a new file to edit or import an existing file to G Mark for laser processing For G Mark software operation manual you can refer to G Mark software user manual in the StellarMark CD from accessory box ...

Страница 60: ...owing an error message when you open the G Mark software program Please perform the following steps to solve problem Error message 1 Please insert KeyPro 1 Fix 1 Please close the G Mark software program and re plug the KeyPro from PC Laptop and then repoen the G Mark software program Fix 2 Step 1 Select the Start button and type device manager Step 2 Select Device Manager ...

Страница 61: ...StellarMark IFII Series User Manual Rev 5 0 57 Step 3 Please check if there is any USB device from the below chart Step 4 Then click on USB Driver and click on right mouse button and update the driver ...

Страница 62: ...StellarMark IFII Series User Manual Rev 5 0 58 Step 5 Click on Browse my computer for driver software Step 6 Key in the specific path C Program Files G Mark Lib Drivers MC1 Then press Next ...

Страница 63: ...u can reopen the G Mark software Error message 2 Controller not found Fix 1 Reconnect the USB cable between a PC or Laptop and the Control unit and then reopen the G Mark software program Fix 2 Update the controller driver Step 1 Select the Start button and type device manager ...

Страница 64: ...StellarMark IFII Series User Manual Rev 5 0 60 Step 2 Select Device Manager Step 3 Please check if there is any USB device from the below chart ...

Страница 65: ...StellarMark IFII Series User Manual Rev 5 0 61 Step 4 Then click on USB Driver and click on right mouse button and update the driver Step 5 Click on Browse my computer for driver software ...

Страница 66: ...StellarMark IFII Series User Manual Rev 5 0 62 Step 6 Key in the specific path C Program Files G Mark Lib Drivers MC1 Then press Next Step 7 Press Finish and now you can activate the G Mark software ...

Страница 67: ... of the device manager but cannot update the driver We recommended you disable the driver signature enforcement on safe mode please perform the following steps Step 1 Select the Start button Step 2 Type startup Step 3 Select Change advanced startup options Step 4 Select Restart now under the Advanced startup area ...

Страница 68: ...StellarMark IFII Series User Manual Rev 5 0 64 Step 5 Select Troubleshoot Step 6 Select Advanced Options ...

Страница 69: ...StellarMark IFII Series User Manual Rev 5 0 65 Step 7 Select Startup Settings Step 8 Select Restart ...

Страница 70: ...nual Rev 5 0 66 Step 9 A menu will appear where you can press F7 on your keyboard to choose Disable driver signing enforcement Step 10 After rebooting go to C Program Files x86 G Mark Lib Drivers MCx and click on Setup exe to install ...

Страница 71: ...eries User Manual Rev 5 0 67 Step 11 Windows Security will pop up and then click on Install this driver software anyway Step 12 After installing go to device manager and make sure the controller driver has been installed ...

Страница 72: ...ou can change the series and model type through the model manager program The following steps illustrate how to change the series and model type 6 5 1 Change the User Account Control Settings Step 1 Please go to control panel and click on User Accounts Step 2 Then click on Change User Account Control settings ...

Страница 73: ...User Manual Rev 5 0 69 Step 3 Set the notification to be Never notify and press OK to complete the setting 6 5 2 Setting the Run this program as an administrator Step 1 Find the G Mark Lib which is located at the desktop of PC ...

Страница 74: ... Manual Rev 5 0 70 Step 2 Position the mouse on the G Mark Lib and right click properties for the G Mark Lib appears then press the properties Step 3 Click Compatibility tab and select checkbox Run this program as an administrator ...

Страница 75: ...StellarMark IFII Series User Manual Rev 5 0 71 Step 4 Press OK to complete the setting Step 5 Find the ModelManager exe which is located at C Program Files x86 G Mark Lib ...

Страница 76: ... Rev 5 0 72 Step 6 Positions the mouse on the ModelManager exe and right click properties for the ModelManager exe appears then press the properties Step 7 Click Compatibility tab and select checkbox Run this program as an administrator ...

Страница 77: ... 5 0 73 Step 8 Press OK to complete the setting 6 5 3 Change the series and model type Step 1 Open the ModelManager exe which is located at C Program Files x86 G Mark Lib Step 2 Model Manger window will show up select your series model type ...

Страница 78: ...StellarMark IFII Series User Manual Rev 5 0 74 Step 3 Press OK to complete the change series and model type NOTE Wrong setting for series and model type may cause the machine out of order ...

Страница 79: ...ms Each waveform is optimized for pulse energy and peak power at a given pulse duration and frequency These waveforms can be used at any power demand and frequency giving users great scope for pulse characteristic optimization for specific applications 6 6 2 Waveform Application One of the waveform benefits is to do many marking effects on metal materials The illustration utilizes a GCC LaserPro S...

Страница 80: ... be guaranteed to repeat correctly 2 Different spot size will generate different laser marking contrast ensure materials placed evenly during laser processing will help deliver consistent laser marking quality 3 The color of marking may vary to different colors when viewing in different angle with reflecting ambient light White Effect Marking with WF0 Deep Effect Deep engraving with WF0 Polishing ...

Страница 81: ...Frequenct kHz Pulse Energy mJ 0 200 25 0 8 220 35 0 57 200 37 0 8 200 50 1 2 1 120 55 0 36 2 55 90 0 22 3 25 170 0 12 4 18 270 0 074 5 10 15 290 0 068 11 220 35 0 57 12 205 37 0 54 13 200 39 0 51 14 190 44 0 45 15 160 48 0 42 16 140 51 0 39 17 120 55 0 36 18 100 60 0 33 19 95 63 0 32 20 85 68 0 29 21 75 72 0 28 22 65 80 0 25 23 55 90 0 22 24 45 105 0 19 25 35 125 0 16 26 25 170 0 12 27 18 270 0 07...

Страница 82: ...StellarMark IFII Series User Manual Rev 5 0 78 6 6 4 Waveform Parameter Adjustment Waveform selection can be adjusted under the Marking Parameter tab of the Property Table in StellarMark G Mark software ...

Страница 83: ...StellarMark IFII Series User Manual Rev 5 0 79 Chapter 7 Lens Adjustment Import Lens Parameter Lens Parameter Card Lens Parameter Adjustment ...

Страница 84: ...orm the following steps to import the factory default scan lens parameters Step 1 Start the G Mark software program Step 2 Select File Configuration Import Export NOTE The lens parameter in the CD is specific to each laser marker apply it to different laser marker may cause imprecise marking results If changing to different scan lens is required always re do the lens calibration following steps in...

Страница 85: ...StellarMark IFII Series User Manual Rev 5 0 81 Step 3 Check the Application Config Lens Setting Object Default and Machine Check Config selections Step 4 Click on the Folder location icon shown below ...

Страница 86: ... the Installation CD and select OK Note The lens parameter folder is named with the serial number of your machine If there is no Lens Parameter folder found under G Mark installation CD please skip to section 7 2 and follow the Lens Parameter Card instructions Step 6 Click the Import button ...

Страница 87: ...ser Manual Rev 5 0 83 Step 7 Click on the OK button after the Status screen shows Complete Step 8 Click on OK when the Restart message prompts up Step 9 Click on the Work Area Tab under the Property Table after G Mark restarts ...

Страница 88: ...FII Series User Manual Rev 5 0 84 Step 10 The Lens parameter can be found in the Lens list Named with the serial number of your machine Step 11 Click on Apply after selecting the Lens and the settings will be loaded ...

Страница 89: ...marker and the G Mark marking software must be adjusted to match each other Otherwise the marking lines will be distorted or will have an improper scale of the marking content Step 1 Take out the lens parameter card from the accessory kit Step 2 Open G Mark marking software Step 3 Click on work area from property table and press Lens Manager ...

Страница 90: ...StellarMark IFII Series User Manual Rev 5 0 86 Step 4 Press New to create a new name for the lens and press OK Step 5 Click Correction to settings lens ...

Страница 91: ...Step 6 Fill in the numbers that are showing on the card to the below table Press Exit to save the settings of the lens NOTE If the size of scan lens is changed the lens parameter will be varied too Follow section 7 3 to calibrate with new scan lens ...

Страница 92: ...se perform the following steps to find the appropriate lens parameter when changing to different scan field of scan lens Step 1 Create new name for the new lens Step 2 Change the mark area and press Exit to save the settings Step 3 Mark the below pattern and check the output quality ...

Страница 93: ...tep 5 If the figure becomes protuberant in X axis the X value will need to be Increased like 0 002 while if now it become indentation the X value will have to be reduced to as 0 0014 Keep adjusting the value until it is acceptable Step 6 If the square is trapezoid go back to the lens setup to correct the irregular square ...

Страница 94: ...1 the adjustment range is from 0mm up to 0 5mm For 140x140mm scan lens Keep adjusting the value until it is acceptable Step 8 If there is an irregular parallelogram go to the lens parameter under the Configure to correct the irregular angle Step 9 Keep adjusting the value until it is acceptable ...

Страница 95: ...es User Manual Rev 5 0 91 Step 10 Measure the lengths of A B C D and E of the square pattern Make sure these lengths match to the expected length you set from the marking software Step 11 If not correct scale proportionally ...

Страница 96: ...StellarMark IFII Series User Manual Rev 5 0 92 Chapter 8 Error Message ...

Страница 97: ...ill be unable to fire until the problems are solved Follow the trouble shooting instructions on the error message window to fix the problem if cannot fix the issues please contact GCC local representative for help Once the problem is solved OK button must be pressed to close the message window The Error Message Includes Error Indications X Scan head is abnormal Y Scan head is abnormal Base plate t...

Страница 98: ...StellarMark IFII Series User Manual Rev 5 0 94 Chapter 9 External Control I O Pin Assignment Laser Working Flow Chart Laser Reaction Timing Diagram ...

Страница 99: ...als Stellar Mark External device available to communicate with external devices Alarm Out OUTPUT When Alarm is inactivated the laser marker will send signal out When Alarm is activated the laser marker will send out a signal out When marking software is opened the Alarm will be activated and laser marker will send a signal out in the beginning of work Until the Execute button is pressed and the Ma...

Страница 100: ...out When laser marker is firing it will send a signal out I1 I8 INPUT There are 8 input signals External device Stellar Mark available to communicate with external devices STOP INPUT When Stop pin and Ground pin are at short status laser marker will stop working START INPUT When Start pin and Ground pin are at short status laser marker will trigger the fire E Stop INPUT This is terminal used to co...

Страница 101: ... IFII Series User Manual Rev 5 0 97 2 Output pins NOTE Signal high and low definitions in G Mark Library software Not Available The pin 9 to pin 16 output status are not available to communicate with laser marker ...

Страница 102: ...StellarMark IFII Series User Manual Rev 5 0 98 9 2 Laser Working Flow Chart ...

Страница 103: ... step of Ready to fire will be depend on the size of working object C D After the file reading is completed it will take less than 1 µ sec for the external device to receive a Ready signal from the laser marker E It will take between 0 1m sec 50m sec for laser to trigger the fire after receive the command of Start F Ready signal is OFF when laser is firing G Job is completed G H it will take about...

Страница 104: ... 20μsec Laser signal Output External device delaying time It will take about X 1 µ sec for the external device to receive an output signal from the laser marker Laser signal Output External device delaying time It will take about 10 µ sec X 20 µ sec for the laser marker to receive an input signal from the external device ...

Страница 105: ...StellarMark IFII Series User Manual Rev 5 0 101 Chapter 10 Basic Maintenance ...

Страница 106: ...with the work environment the frequency of usage the quality of the exhaust system etc 10 1 Regular Spot Check Before each usage inspect the machine the power and connector cables and the working environment Look for frays in cables proper connections and any abnormalities that could have an effect on marking performance and or user safety Be sure that the IFII series is properly secured and mount...

Страница 107: ...e residue that builds up on the focal lenses can distort the laser beam passing through resulting in poor quality markings and may cause cracks by the uneven heat conduction Please perform the following steps Step 1 Remove the focal lens from the marker Step 2 Apply some lens cleaner on cotton swab ...

Страница 108: ...one if the lens cleaner will not remove the mark Be careful not to scratch the lens After the mark is removed follow the steps used to clean residue marks in order to finish the cleaning WARNING Acetone is an EXTREMELY FLAMMABLE LIQUID AND VAPOUR The vapour is heavier than air and may spread long distances making distant ignition and flashback possible ...

Страница 109: ...Series User Manual Rev 5 0 105 NOTE Never touch the scan lens with your bare hand The oils from your hand will distort the laser beam passing through the lens Use finger cs or rubber gloves when cleaning is recommended ...

Страница 110: ...StellarMark IFII Series User Manual Rev 5 0 106 Chapter 11 Appendix IFII Series Specification ...

Страница 111: ...tive 2014 30 EU Electromagnetic Compatibility Directive Maximum Marking Operating System Model No Laser Source Electrical Requirements Dimensions Laser Makrer Weight Control Unit Weight Max Linear Marking Speed StellarMark IFIIS 20 30 60JFL Scan Lens Model No 70 110 180 300 Working Area 70x70 mm 110x110 mm 180x180 mm 300x300 mm Spot Size 27 μm 44 μm 71 μm 114 μm Working Distance 142 1 mm 220 2 mm ...

Отзывы: