Vhandy Technology
GCAN-208 user manual
4.Technical specifications
Connection method
Optical fiber
SC, ST, FC, single-mode, multi-mode, single-core, dual-
core optional
CAN
OPEN3 terminal block
Interface characteristics
Optical fiber transmission
method
Single-mode, multi-mode optional
CAN protocol
Follow ISO 11898 standard, support CAN2.0A/B
CAN baud rate
5Kbit/s~1Mbit/s, configured by dial switch
Electrical isolation
DC-2500V
CAN terminal resistance
Has been integrated, through the dial switch to choose
whether to connect
Power supply
Supply voltage
+9~24V DC ±20%
Supply current
50mA max
Environmental test
Operating temperature
-40℃~+85℃
Working humidity
15%~90%RH, no condensation
EMC test
EN 55024:2011-09
EN 55022:2011-12
Protection level
IP 20
Basic Information
Dimensions
118mm *93mm *22mm
weight
230g