OPERATION OVERVIEW 

Unit is an automatic device that requires no user interaction for daily operation (provided city pressure and power 

parameters are met). An emergency bypass valve is provided on the faceplate for use by the owner in the event the Easy 

Series System water pressure changes and city water is required to continue temporary operation to the points of use. 

OPERATING PARAMETERS:

O

pen flow rate

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(28.5 LPM) 5 GPM

Service flow rate, filter

.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 18.9 LPM) 3 GPM 

Output pressure     .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .(3 bar) 45 PSI
FEED WATER and POWER REQUIREMENTS:

Pressure     .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .(2.7-3.4bar) 40-90 PSI

Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (10°-26°C) 50°-80°F

Max TDS     .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 1,000 mg / L

Max chlorine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0 mg / L

Electrical    .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .110, 60 HZ, 2 amps

Delivery Pump running - Sound emission . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <50dB max
SIZE/WEIGHT: 

Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  (749.3mm) 29.5”

Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(609.6mm) 24”

Depth    .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .(457.2mm) 18”

Ship (dry) weight    .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .(32 kg) 70 lbs

Wet weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(97 kg) 214 lbs
PERFORMANCE DATA:

Avg percent reduction of TDS     .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   91.8%

Avg TDS influent challenge concentration

    .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 750 ± 4mg/L

Max permissible product water concentration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187 mg/L

Avg product water concentration    .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 62 mg/L

TDS range (customer specific) 

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50-200 ppm*

TDS control range means the range within which the water is to be formulated or the amount of TDS retained to meet 

a customer’s specific requirement.
*Certified by manufacturer testing at the factory and at the user’s site as part of System installation start up procedure.

Daily production rate @ 70 psi/77°F 

(not tested by NSF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  500 GPD

Daily production rate @ 50 psi/75°F 

(as tested by NSF)    .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   328 GPD

Highest efficiency rating in the industry.   Efficiency rating means the 

percentage

 of the influent water to the System 

that is available to the user as reverse osmosis treated water coming out of the System under normal operating 

conditions (approximate typical daily usage.)  Testing was performed under standard laboratory conditions, actual 

performance may vary.
WARNING:

Do not use where water is microbiologically unsafe or of unknown quality. Replacement components are to be man-

ufactured or approved by Global Customized Water to maintain efficiencies. System is to be serviced at prescribed 

time/usage intervals according to this document, to maintain warranty. 

CERTIFICATIONS:

Fitting, filter and housing components are NSF And/or WQA certified.

UNIT SPECS

Содержание Easy 360

Страница 1: ...info gcwater com 20 Opportunity Road Camdenton MO 65020 805 484 1589 www GlobalCustomizedWater com Easy 360 720 Reverse Osmosis Unit Guide ...

Страница 2: ... TO OTHERS NOR EMPLOYED FOR DESIGN PROCUREMENT OR MANUFACTURING PURPOSES WITHOUT SPECIFIC WRITTEN PERMISSION FROM GLOBAL CUSTOMIZED WATER CONTENTS UNIT SPECS 3 INSTALLATION 4 6 START UP INSTRUCTIONS 7 FILTER REPLACEMENT 8 EMERGENCY BYPASS 8 PRODUCTION RATE CHECK 9 BLENDING VALVE CALIBRATION 9 ROUTINE SYSTEM CHECK 7 TROUBLESHOOTING 11 SYSTEM SERVICE LOG 12 WARRANTY 13 ...

Страница 3: ...ncentration 62 mg L TDS range customer specific 50 200 ppm TDS control range means the range within which the water is to be formulated or the amount of TDS retained to meet a customer s specific requirement Certified by manufacturer testing at the factory and at the user s site as part of System installation start up procedure Daily production rate 70 psi 77 F not tested by NSF 500 GPD Daily prod...

Страница 4: ...require back flow devices Both the air gap device and back flow device are not supplied as part of the unit These devices are available through your standard plumbing supply house Alternate Bypass If preferred owner installer is to provide plumbing of ball valve shut off bypass on wall as pictured above Points of use may be pre plumbed as a single line through wall with manifold afterward 6 RO equ...

Страница 5: ...0 720 Flow Diagram without RO System TO ICE MACHINE TO ESPRESSO BREWER CITY WATER FROM MANIFOLD TO ICE MACHINE TO ESPRESSO BREWER Back Flow Device TO Water Heater TO ICE MACHINE SOFT HARD WATER TO ESPRESSO BREWER CITY WATER SOFT WATER Shut Off Ball Valves FROM MANIFOLD INSTALLATION ...

Страница 6: ...old Assembled Easy Series Unit Connection Install supplied 3 ea 3 8 tube elbow fitting at inlet outlet and drain points on the top of the Easy System Install supplied 15 ft BLUE 3 8 tubing where needed Install supplied 1 ea 1 2 MPT x 3 8 JG fitting at the cold domestic feed inlet valve 3 8 Hook up Tubing Feed Water Connection Fitting POU Manifold comes in three 3 pre assembled pieces that hook tog...

Страница 7: ... of test mode and put back 1 4 black test port tube behind the middle pre filter See picture on page one Unit will now begin to fill the storage tank 6 As the system unit is filling turn the black blending valve on the face plate slightly counterclockwise and turn on tds meter by pushing the on off button to the right of the meter Tds should read between 80 110 ppm and adjust accordingly The tank ...

Страница 8: ...e blue cap on new filter and line up notches on filter to match placement on head push up snugly and turn to the right to lock Repeat for all other filters you are installing 6 Turn the ball valve on water line going to city in by turning blue lever 90º deg 7 Check filter in gauge it should go back up to 60 psi 8 Check filter out gauge it should read similar to filter in gauge 9 Turn Pump ON OFF s...

Страница 9: ... 6 When your calibration is completed return the black tube to underneath the middle filter tucked away neatly Calibration can only occur when the storage tank is filling The blending valve is factory set closed and will need calibration at the location of install To adjust the TDS on the Easy Series complete the following steps 1 Check the filter out gauge If gauge is reading similar to filter in...

Страница 10: ...ies Remember to turn off TDS meter when finished CHECK THE BYPASS HANDLE POSITION Keep the yellow bypass handle in the off position at all times unless otherwise instructed by the Troubleshooting Guide Please contact your service provider when bypass handle is moved into bypass Emergency situations which require putting the bypass handle into the bypass position turning the bypass handle yellow ha...

Страница 11: ...es are in the on position and water to your building was not turned off See step 4 If you had to turn the water on to EasySystem wait 20 minutes for pressure above 35 psi to be restored and for the motor pump to begin running normally Is the Pump Motor on See step 4 Step 4 If Steps 1 3 fail to get the EasySystem producing water to the POU call your Store Facility Service Center or Global immediate...

Страница 12: ...PAGE 12 DATE PRE FILTER POST FILTER MEMBRANE CLEANING OTHER TECH NAME START UP DATE START UP BY TDS PPM INCOMING PSI SYSTEM SERVICE LOG ...

Страница 13: ...e instructions enclosed with the system The War ranty does not cover any non Global parts the costs of repairs or adjustments to the unit that may be needed because of the use of improper parts equipment or materials unauthorized alterations of the unit or failure of a unit caused by such alterations or by unau thorized repairs The Warranty does not cover malfunctions of the unit due to tampering ...

Отзывы: