1 Year Limited Warranty for Global Water Treatment Systems

Global Customized Water warranties it’s systems to be free from defects in material and workmanship as follows:

WHAT IS COVERED:

One (1) year from the date of purchase. Pump, motor & electrical controls, filter housings, membrane housings, brackets, storage tanks, 

media tanks, tubing, fittings, gauges, valves are covered for one year provided suggested maintenance is performed.

LIMITS ON WARRANTY:

The design of the overall treatment system and the performance of these systems are related to the chemistry of the water being 

treated, this warranty is limited to systems installed on municipal water supplies and installed on supplies within parameters specified 

on performance data sheets.Replacement of pre and post elements is part of the normal maintenance required by your systems. These 

replacements are not covered and preventative maintenance must be performed in accordance with the unit guide to maintain this 

warranty. 

This warranty does not include damage to your system do to:

•  Abuse, misuse or neglect

•  Excessive inlet water pressure (over 90 psi)

•  Excessive water temperature (over 80 degrees F)

•  Freezing, alterations or misapplication

• 

Change in the influent water characteristics

This equipment must be installed and operated in accordance with Global Customized Water’s recommendations and applicable state 

and local codes.The Global Customized  Water  Limited Warranty extends to the original purchaser of the system. This warranty covers 

all parts and factory labor needed to repair any Global supplied item that proves to be defective in material, workmanship or factory 

preparation.The above mentioned warranty applies for the first full calendar year from date of purchase. Defective items are subject to 

the following exclusions: membranes, filters, 0-rings, and all other parts or components that require regular replacement  as a result of 

ordinary usage herein classified as consumables.

DISCLAIMERS:

This warranty applies only if the system is installed and used in compliance with the instructions  enclosed with the system. The War-

ranty does not cover any non Global parts, the costs of repairs or adjustments  to the unit that may be needed because of the use of 

improper parts, equipment or materials, unauthorized alterations of the unit, or failure of a unit caused by such alterations or by unau-

thorized repairs. The Warranty does not cover malfunctions  of the unit due to tampering, misuse, alteration, lack of regular mainte-

nance, misapplication, fouling due to hydrogen sulfide or iron, scaling from excessive hardness, or excessive membrane hydrolysis due 

to chlorine levels in excess of 1.0 mg/L. In addition, damage to the unit due to fire, accident, negligence, act of God, or events beyond 

the control of Global are not covered by this warranty.

INCIDENTAL AND CONSEQUENTIAL DAMAGES:

Global does not assume responsibility  for payment of incidental and consequential damages as a result of the failure of this unit to 

comply with express or implied warranties, such as lost time, inconvenience, damage to personal property, loss of revenue, commercial 

losses, postage, travel, telephone  expenditures, or other losses of this nature.  Some states do not allow the exclusion or limitation of 

incidental or consequential damages, so this exclusion may not apply to you.

OWNER’S WARRANTY RESPONSIBILITIES:

Under the provisions of the Warranty, the owner is expected to schedule maintenance,  as described in the Manual that accompanies  

the system. Neglect, improper maintenance, abuse, or unapproved modifications may invalidate the Warranty. Should your unit develop 

a defect or otherwise fail to perform in accordance with this warranty, you should contact Global Customized Water or the dealer you 

purchased the product from.

IMPLIED WARRANTIES:

The implied at-law warranties of merchantability and fitness for a particular purpose shall terminate on the date one year after the date 

of purchase. Note: some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply 

to you.

OTHER RIGHTS:

This Warranty gives you specific legal rights and you may also have other rights which vary from state to state.

Warranty activation is required. Call Global: 805.484.1589. You can also email us at [email protected]

WARRANTY

Содержание Easy 360

Страница 1: ...info gcwater com 20 Opportunity Road Camdenton MO 65020 805 484 1589 www GlobalCustomizedWater com Easy 360 720 Reverse Osmosis Unit Guide ...

Страница 2: ... TO OTHERS NOR EMPLOYED FOR DESIGN PROCUREMENT OR MANUFACTURING PURPOSES WITHOUT SPECIFIC WRITTEN PERMISSION FROM GLOBAL CUSTOMIZED WATER CONTENTS UNIT SPECS 3 INSTALLATION 4 6 START UP INSTRUCTIONS 7 FILTER REPLACEMENT 8 EMERGENCY BYPASS 8 PRODUCTION RATE CHECK 9 BLENDING VALVE CALIBRATION 9 ROUTINE SYSTEM CHECK 7 TROUBLESHOOTING 11 SYSTEM SERVICE LOG 12 WARRANTY 13 ...

Страница 3: ...ncentration 62 mg L TDS range customer specific 50 200 ppm TDS control range means the range within which the water is to be formulated or the amount of TDS retained to meet a customer s specific requirement Certified by manufacturer testing at the factory and at the user s site as part of System installation start up procedure Daily production rate 70 psi 77 F not tested by NSF 500 GPD Daily prod...

Страница 4: ...require back flow devices Both the air gap device and back flow device are not supplied as part of the unit These devices are available through your standard plumbing supply house Alternate Bypass If preferred owner installer is to provide plumbing of ball valve shut off bypass on wall as pictured above Points of use may be pre plumbed as a single line through wall with manifold afterward 6 RO equ...

Страница 5: ...0 720 Flow Diagram without RO System TO ICE MACHINE TO ESPRESSO BREWER CITY WATER FROM MANIFOLD TO ICE MACHINE TO ESPRESSO BREWER Back Flow Device TO Water Heater TO ICE MACHINE SOFT HARD WATER TO ESPRESSO BREWER CITY WATER SOFT WATER Shut Off Ball Valves FROM MANIFOLD INSTALLATION ...

Страница 6: ...old Assembled Easy Series Unit Connection Install supplied 3 ea 3 8 tube elbow fitting at inlet outlet and drain points on the top of the Easy System Install supplied 15 ft BLUE 3 8 tubing where needed Install supplied 1 ea 1 2 MPT x 3 8 JG fitting at the cold domestic feed inlet valve 3 8 Hook up Tubing Feed Water Connection Fitting POU Manifold comes in three 3 pre assembled pieces that hook tog...

Страница 7: ... of test mode and put back 1 4 black test port tube behind the middle pre filter See picture on page one Unit will now begin to fill the storage tank 6 As the system unit is filling turn the black blending valve on the face plate slightly counterclockwise and turn on tds meter by pushing the on off button to the right of the meter Tds should read between 80 110 ppm and adjust accordingly The tank ...

Страница 8: ...e blue cap on new filter and line up notches on filter to match placement on head push up snugly and turn to the right to lock Repeat for all other filters you are installing 6 Turn the ball valve on water line going to city in by turning blue lever 90º deg 7 Check filter in gauge it should go back up to 60 psi 8 Check filter out gauge it should read similar to filter in gauge 9 Turn Pump ON OFF s...

Страница 9: ... 6 When your calibration is completed return the black tube to underneath the middle filter tucked away neatly Calibration can only occur when the storage tank is filling The blending valve is factory set closed and will need calibration at the location of install To adjust the TDS on the Easy Series complete the following steps 1 Check the filter out gauge If gauge is reading similar to filter in...

Страница 10: ...ies Remember to turn off TDS meter when finished CHECK THE BYPASS HANDLE POSITION Keep the yellow bypass handle in the off position at all times unless otherwise instructed by the Troubleshooting Guide Please contact your service provider when bypass handle is moved into bypass Emergency situations which require putting the bypass handle into the bypass position turning the bypass handle yellow ha...

Страница 11: ...es are in the on position and water to your building was not turned off See step 4 If you had to turn the water on to EasySystem wait 20 minutes for pressure above 35 psi to be restored and for the motor pump to begin running normally Is the Pump Motor on See step 4 Step 4 If Steps 1 3 fail to get the EasySystem producing water to the POU call your Store Facility Service Center or Global immediate...

Страница 12: ...PAGE 12 DATE PRE FILTER POST FILTER MEMBRANE CLEANING OTHER TECH NAME START UP DATE START UP BY TDS PPM INCOMING PSI SYSTEM SERVICE LOG ...

Страница 13: ...e instructions enclosed with the system The War ranty does not cover any non Global parts the costs of repairs or adjustments to the unit that may be needed because of the use of improper parts equipment or materials unauthorized alterations of the unit or failure of a unit caused by such alterations or by unau thorized repairs The Warranty does not cover malfunctions of the unit due to tampering ...

Отзывы: