14
Have questions?
1 (855) 9GO-GBTI
Air Flow Pressure Through Blast Nozzle- CFM
Trouble Shooting Tip
Water Pump Maintenance
Water pump maintenance is extremely critical as the pump is the center piece to your Greener Blast
machine functioning at an optimal level. Keeping your water pump running smoothly is quite simple.
Keep water tank clean of all grits!
Keep screen filter on pump inlet clean and restriction free, to ensure optimal water flow.
Decommissioning Your GBT Unit
Important!
Always close main pot shutoff/slurry hose priot to turning off air compressor and opening
the system air purge valve (located under the air supply inlet) to ensure all compressed air is release
from the system before disconnecting your supply line.
Overnight/Short term:
1. Simply close off the Slurry Hose/ main pot valve.
2. Turn off your air supply and open system air purge. Pot can remain pressurized.
3. Your machine will be ready for blasting the following morning.
Long Term:
1. Close off the Slurry Hose/ main pot valve.
2. Activate dead man to blow blast hose clean.
3. Disconnect Slurry Hose/ main pot valve.
4. Open Slurry Hose/ main pot valve and allow material to flow out. This process can expedited with
the air compressor on and the machine switched to pot fill. Throttle the Main Pot Shut-off/ Slurry
Hose to ensure pot remains pressurized. This will force the material out under hydraulic pressure
rather than gravity.
5. Rinse inside pot until clean water runs out of Main Pot Shutoff/ Slurry Hose. This will remove any
and all potential media that may remain in the bottom bowl of your blast pot.